Program Version:EnergyPlus, Version 24.1.0-9d7789a3ac, YMD=2024.09.12 18:15
Tabular Output Report in Format: HTML
Building: Building 1
Environment: RUN PERIOD 1 ** MILAN - ITA IWEC Data WMO#=160660
Simulation Timestamp: 2024-09-12 18:15:00
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 213.08 | 630.41 | 733.04 |
| Net Site Energy | 213.08 | 630.41 | 733.04 |
| Total Source Energy | 718.58 | 2125.97 | 2472.06 |
| Net Source Energy | 718.58 | 2125.97 | 2472.06 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating Water | 3.613 |
| District Heating Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 338.00 |
| Net Conditioned Building Area | 290.68 |
| Unconditioned Building Area | 47.32 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating Water [GJ] | District Heating Steam [GJ] | Water [m3] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.38 | 0.00 | 0.00 |
| Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.80 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 26.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 32.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 58.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.80 | 144.38 | 0.00 | 0.00 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating Water [GJ] | District Heating Steam [GJ] | Water [m3] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.38 | 0.00 | 0.00 |
| Cooling | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.80 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | General | 26.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | General | 32.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating Water [GJ] | District Heating Steam [GJ] | Water [m3] | |
| Heating | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.38 | 0.00 | 0.00 |
| Cooling | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.80 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | MIDRISEAPARTMENT APARTMENT | 11.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MIDRISEAPARTMENT CORRIDOR | 14.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MIDRISEAPARTMENT APARTMENT | 32.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Water Intensity [MJ/m2] | District Heating Steam Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 90.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.71 | 496.70 | 0.00 | 0.00 |
| Other | 111.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 202.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.71 | 496.70 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Water Intensity [MJ/m2] | District Heating Steam Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 78.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| HVAC | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.99 | 427.16 | 0.00 | |
| Other | 96.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Total | 174.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.99 | 427.16 | 0.00 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 58.900 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 58.900 | 100.00 |
| Total On-Site and Utility Electric Sources | 58.900 | 100.00 |
| Total Electricity End Uses | 58.900 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | |
| Air to Air Heat Recovery for Cooling | 0.00 | |
| Air to Air Heat Recovery for Heating | 0.00 | |
| High-Temperature Geothermal* | 0.00 | |
| Solar Water Thermal | 0.00 | |
| Solar Air Thermal | 0.00 | |
| Total On-Site Thermal Sources | 0.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | - |
| Condensate Collection | 0.00 | - |
| Groundwater Well | 0.00 | - |
| Total On Site Water Sources | 0.00 | - |
| - | - | - |
| Initial Storage | 0.00 | - |
| Final Storage | 0.00 | - |
| Change in Storage | 0.00 | - |
| - | - | - |
| Water Supplied by Utility | 0.00 | - |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 0.00 | - |
| Total Water End Uses | 0.00 | - |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 0.00 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 7123.67 |
Table of Contents
TopBUILDING ENERGY PERFORMANCE - ELECTRICITY
| Meter |BUILDING ENERGY PERFORMANCE - DISTRICT HEATING WATER
| Meter |BUILDING ENERGY PERFORMANCE - DISTRICT COOLING
| Meter |BUILDING ENERGY PERFORMANCE - ELECTRICITY PEAK DEMAND
| Meter |BUILDING ENERGY PERFORMANCE - DISTRICT HEATING WATER PEAK DEMAND
| Meter |BUILDING ENERGY PERFORMANCE - DISTRICT COOLING PEAK DEMAND
| Meter |Life-Cycle Cost Report
| Entire Facility |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
General| Value | |
| Program Version and Build | EnergyPlus, Version 24.1.0-9d7789a3ac, YMD=2024.09.12 18:15 |
| RunPeriod | RUN PERIOD 1 |
| Weather File | MILAN - ITA IWEC Data WMO#=160660 |
| Latitude [deg] | 45.62 |
| Longitude [deg] | 8.73 |
| Elevation [m] | 211.00 |
| Time Zone | 1.00 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 280.80 | 70.20 | 70.20 | 70.20 | 70.20 |
| Above Ground Wall Area [m2] | 280.80 | 70.20 | 70.20 | 70.20 | 70.20 |
| Window Opening Area [m2] | 39.36 | 11.20 | 4.48 | 11.20 | 12.48 |
| Gross Window-Wall Ratio [%] | 14.02 | 15.95 | 6.38 | 15.95 | 17.78 |
| Above Ground Window-Wall Ratio [%] | 14.02 | 15.95 | 6.38 | 15.95 | 17.78 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 220.05 | 55.08 | 70.20 | 70.20 | 24.57 |
| Above Ground Wall Area [m2] | 220.05 | 55.08 | 70.20 | 70.20 | 24.57 |
| Window Opening Area [m2] | 31.36 | 11.20 | 4.48 | 11.20 | 4.48 |
| Gross Window-Wall Ratio [%] | 14.25 | 20.33 | 6.38 | 15.95 | 18.23 |
| Above Ground Window-Wall Ratio [%] | 14.25 | 20.33 | 6.38 | 15.95 | 18.23 |
| Total | |
| Gross Roof Area [m2] | 169.00 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| TZ_0-A1.B | 19.22 | Yes | Yes | 51.89 | 1.00 | 22.68 | 0.00 | 2.24 | 2.24 | 3.8750 | 35.32 | 5.3820 |
| TZ_0-A1.LK | 37.29 | Yes | Yes | 100.68 | 1.00 | 15.25 | 0.00 | 3.36 | 3.36 | 3.8750 | 35.32 | 5.3820 |
| TZ_0-A1.W | 10.81 | Yes | Yes | 29.19 | 1.00 | 7.43 | 0.00 | 1.12 | 1.12 | 3.8750 | 35.32 | 5.3820 |
| TZ_0-A2.B | 18.31 | Yes | Yes | 49.43 | 1.00 | 22.14 | 0.00 | 2.24 | 2.24 | 3.8750 | 35.32 | 5.3820 |
| TZ_0-A2.LK | 48.90 | Yes | Yes | 132.03 | 1.00 | 35.10 | 0.00 | 5.60 | 5.60 | 3.8750 | 35.32 | 5.3820 |
| TZ_0-A2.W | 10.81 | Yes | Yes | 29.19 | 1.00 | 7.43 | 0.00 | 1.12 | 1.12 | 3.8750 | 35.32 | 5.3820 |
| TZ_0-H | 23.66 | No | Yes | 63.88 | 1.00 | 30.38 | 0.00 | 5.76 | 5.76 | 9.9028 | 0.0000 | |
| TZ_1-A3.B1 | 19.22 | Yes | Yes | 51.89 | 1.00 | 22.68 | 0.00 | 2.24 | 2.24 | 3.8750 | 35.32 | 5.3820 |
| TZ_1-A3.B2 | 18.31 | Yes | Yes | 49.43 | 1.00 | 22.14 | 0.00 | 2.24 | 2.24 | 3.8750 | 35.32 | 5.3820 |
| TZ_1-A3.LK | 86.19 | Yes | Yes | 232.71 | 1.00 | 50.36 | 0.00 | 8.96 | 8.96 | 3.8750 | 35.32 | 5.3820 |
| TZ_1-A3.W1 | 10.81 | Yes | Yes | 29.19 | 1.00 | 7.43 | 0.00 | 1.12 | 1.12 | 3.8750 | 35.32 | 5.3820 |
| TZ_1-A3.W2 | 10.81 | Yes | Yes | 29.19 | 1.00 | 7.43 | 0.00 | 1.12 | 1.12 | 3.8750 | 35.32 | 5.3820 |
| TZ_1-H | 23.66 | No | Yes | 63.88 | 1.00 | 30.38 | 0.00 | 2.24 | 2.24 | 9.9028 | 0.0000 | |
| Total | 338.00 | 912.60 | 280.80 | 0.00 | 39.36 | 39.36 | 4.7189 | 41.07 | 4.6285 | |||
| Conditioned Total | 290.68 | 784.84 | 220.05 | 0.00 | 31.36 | 31.36 | 3.8750 | 35.32 | 5.3820 | |||
| Unconditioned Total | 47.32 | 127.76 | 60.75 | 0.00 | 8.00 | 8.00 | 9.9028 | 0.0000 | ||||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| 0-A1.B | 19.22 | Yes | Yes | 1.00 | TZ_0-A1.B | MIDRISEAPARTMENT APARTMENT | 0-A1.B | 3.8750 | 35.32 | 5.3820 | |
| 0-A1.LK | 37.29 | Yes | Yes | 1.00 | TZ_0-A1.LK | MIDRISEAPARTMENT APARTMENT | 0-A1.LK | 3.8750 | 35.32 | 5.3820 | |
| 0-A1.W | 10.81 | Yes | Yes | 1.00 | TZ_0-A1.W | MIDRISEAPARTMENT APARTMENT | 0-A1.W | 3.8750 | 35.32 | 5.3820 | |
| 0-A2.B | 18.31 | Yes | Yes | 1.00 | TZ_0-A2.B | MIDRISEAPARTMENT APARTMENT | 0-A2.B | 3.8750 | 35.32 | 5.3820 | |
| 0-A2.LK | 48.90 | Yes | Yes | 1.00 | TZ_0-A2.LK | MIDRISEAPARTMENT APARTMENT | 0-A2.LK | 3.8750 | 35.32 | 5.3820 | |
| 0-A2.W | 10.81 | Yes | Yes | 1.00 | TZ_0-A2.W | MIDRISEAPARTMENT APARTMENT | 0-A2.W | 3.8750 | 35.32 | 5.3820 | |
| 0-H | 23.66 | No | Yes | 1.00 | TZ_0-H | MIDRISEAPARTMENT CORRIDOR | 0-H | 9.9028 | 0.00 | 0.0000 | |
| 1-A3.B1 | 19.22 | Yes | Yes | 1.00 | TZ_1-A3.B1 | MIDRISEAPARTMENT APARTMENT | 1-A3.B1 | 3.8750 | 35.32 | 5.3820 | |
| 1-A3.B2 | 18.31 | Yes | Yes | 1.00 | TZ_1-A3.B2 | MIDRISEAPARTMENT APARTMENT | 1-A3.B2 | 3.8750 | 35.32 | 5.3820 | |
| 1-A3.LK | 86.19 | Yes | Yes | 1.00 | TZ_1-A3.LK | MIDRISEAPARTMENT APARTMENT | 1-A3.LK | 3.8750 | 35.32 | 5.3820 | |
| 1-A3.W1 | 10.81 | Yes | Yes | 1.00 | TZ_1-A3.W1 | MIDRISEAPARTMENT APARTMENT | 1-A3.W1 | 3.8750 | 35.32 | 5.3820 | |
| 1-A3.W2 | 10.81 | Yes | Yes | 1.00 | TZ_1-A3.W2 | MIDRISEAPARTMENT APARTMENT | 1-A3.W2 | 3.8750 | 35.32 | 5.3820 | |
| 1-H | 23.66 | No | Yes | 1.00 | TZ_1-H | MIDRISEAPARTMENT CORRIDOR | 1-H | 9.9028 | 0.00 | 0.0000 | |
| Total | 338.00 | 4.7189 | 41.07 | 4.6285 | |||||||
| Conditioned Total | 290.68 | 3.8750 | 35.32 | 5.3820 | |||||||
| Unconditioned Total | 47.32 | 9.9028 | 0.00 | 0.0000 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| MIDRISEAPARTMENT APARTMENT | 290.68 | 290.68 | 0.00 | 0.00 | 3.8750 | 35.32 | 5.3820 |
| MIDRISEAPARTMENT CORRIDOR | 47.32 | 0.00 | 47.32 | 0.00 | 9.9028 | 0.00 | 0.0000 |
| Total | 338.00 | 290.68 | 47.32 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | District Heating Water [W] | District Heating Steam [W] | Water [m3/s] | |
| Time of Peak | 01-JAN-19:20 | - | - | - | - | - | - | - | - | - | 21-JUL-18:20 | 30-JAN-03:10 | - | - |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22048.54 | 0.00 | 0.00 |
| Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9110.11 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 1579.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 3034.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9110.11 | 22048.54 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | District Heating Water [W] | District Heating Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22048.54 | 0.00 | 0.00 |
| Cooling | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9110.11 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | General | 1579.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | General | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating Water [GJ] | Source District Heating Steam [GJ] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 521.70 | 0.00 |
| Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.34 | 0.00 | 0.00 |
| Interior Lighting | 83.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 102.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 186.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.34 | 521.70 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating Water [MJ/m2] | Source District Heating Steam [MJ/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1794.76 | 0.00 |
| Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.58 | 0.00 | 0.00 |
| Interior Lighting | 288.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 353.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 641.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.58 | 1794.76 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating Water [MJ/m2] | Source District Heating Steam [MJ/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1543.49 | 0.00 |
| Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.60 | 0.00 | 0.00 |
| Interior Lighting | 247.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 304.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 551.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.60 | 1543.49 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| FACE 23 | FACE 24 | |
| FACE 18 | FACE 19 | |
| FACE 39 | FACE 40 | |
| FACE 77 | FACE 78 | |
| FACE 44 | FACE 45 | |
| FACE 54 | FACE 55 | |
| FACE 65 | FACE 66 | |
| FACE 7 | FACE 8 | |
| FACE 110 | FACE 111 | |
| FACE 150 | FACE 151 | |
| FACE 104 | FACE 105 | |
| FACE 89 | FACE 90 | |
| FACE 94 | FACE 95 | |
| FACE 126 | FACE 127 | |
| FACE 138 | FACE 139 | |
| FACE 84 | FACE 85 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Version| Version ID | |
| 1 | 24.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | No | No | No | Yes | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.200 | 0.200 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 2.39 | 1.46 | 3.10 | 5.66 | 12.35 | 17.52 | 21.00 | 22.06 | 20.26 | 16.25 | 10.89 | 5.91 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | MILAN - ITA IWEC Data WMO#=160660 | 45.62 | 8.73 | 1.00 | 211.00 | 98816 | 1.1745 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | FixedDefault | NA | NA | NA | 10.0 |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | Building 1 | 0.000 | Suburbs | 4.00000E-002 | 0.40000 | FullExterior | 25 | 1 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | DOE-2 |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Algorithm {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
Space Heat Balance Sizing |
Space Heat Balance Simulation |
|
| 1 | ThirdOrderBackwardDifference | No | No |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.220 | 370.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 13 | 153 | 38 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | TZ_0-A1.B | 0.0 | 0.00 | 0.00 | 0.00 | 10.56 | 10.46 | 1.35 | 1 | 1 | 1 | 8.45 | 13.00 | 8.15 | 13.00 | 0.00 | 2.70 | 2.70 | 51.89 | TARP | DOE-2 | 19.22 | 22.68 | 20.44 | 2.24 | 8 | 2 | 0 | Yes |
| 2 | TZ_0-A1.LK | 0.0 | 0.00 | 0.00 | 0.00 | 5.63 | 9.70 | 1.35 | 1 | 1 | 1 | 2.80 | 8.45 | 6.40 | 13.00 | 0.00 | 2.70 | 2.70 | 100.68 | TARP | DOE-2 | 37.29 | 15.26 | 11.90 | 3.36 | 7 | 3 | 0 | Yes |
| 3 | TZ_0-A1.W | 0.0 | 0.00 | 0.00 | 0.00 | 10.73 | 7.74 | 1.35 | 1 | 1 | 1 | 8.45 | 13.00 | 6.40 | 9.15 | 0.00 | 2.70 | 2.70 | 29.19 | TARP | DOE-2 | 10.81 | 7.43 | 6.31 | 1.12 | 9 | 3 | 0 | Yes |
| 4 | TZ_0-A2.B | 0.0 | 0.00 | 0.00 | 0.00 | 10.55 | 2.42 | 1.35 | 1 | 1 | 1 | 8.45 | 13.00 | 0.00 | 4.65 | 0.00 | 2.70 | 2.70 | 49.43 | TARP | DOE-2 | 18.31 | 22.14 | 19.90 | 2.24 | 9 | 2 | 0 | Yes |
| 5 | TZ_0-A2.LK | 0.0 | 0.00 | 0.00 | 0.00 | 4.04 | 3.37 | 1.35 | 1 | 1 | 1 | 0.00 | 8.45 | 0.00 | 6.40 | 0.00 | 2.70 | 2.70 | 132.03 | TARP | DOE-2 | 48.90 | 35.10 | 29.50 | 5.60 | 10 | 4 | 0 | Yes |
| 6 | TZ_0-A2.W | 0.0 | 0.00 | 0.00 | 0.00 | 10.73 | 5.06 | 1.35 | 1 | 1 | 1 | 8.45 | 13.00 | 3.65 | 6.40 | 0.00 | 2.70 | 2.70 | 29.19 | TARP | DOE-2 | 10.81 | 7.43 | 6.31 | 1.12 | 9 | 3 | 0 | Yes |
| 7 | TZ_0-H | 0.0 | 0.00 | 0.00 | 0.00 | 1.40 | 8.78 | 1.35 | 1 | 1 | 1 | 0.00 | 2.80 | 4.55 | 13.00 | 0.00 | 2.70 | 2.70 | 63.88 | TARP | DOE-2 | 23.66 | 30.38 | 24.62 | 5.76 | 7 | 3 | 0 | Yes |
| 8 | TZ_1-A3.B1 | 0.0 | 0.00 | 0.00 | 0.00 | 10.56 | 10.46 | 4.05 | 1 | 1 | 1 | 8.45 | 13.00 | 8.15 | 13.00 | 2.70 | 5.40 | 2.70 | 51.89 | TARP | DOE-2 | 19.22 | 22.68 | 20.44 | 2.24 | 9 | 2 | 0 | Yes |
| 9 | TZ_1-A3.B2 | 0.0 | 0.00 | 0.00 | 0.00 | 10.55 | 2.42 | 4.05 | 1 | 1 | 1 | 8.45 | 13.00 | 0.00 | 4.65 | 2.70 | 5.40 | 2.70 | 49.43 | TARP | DOE-2 | 18.31 | 22.14 | 19.90 | 2.24 | 9 | 2 | 0 | Yes |
| 10 | TZ_1-A3.LK | 0.0 | 0.00 | 0.00 | 0.00 | 4.41 | 6.01 | 4.05 | 1 | 1 | 1 | 0.00 | 8.45 | 0.00 | 13.00 | 2.70 | 5.40 | 2.70 | 232.71 | TARP | DOE-2 | 86.19 | 50.36 | 41.40 | 8.96 | 14 | 6 | 0 | Yes |
| 11 | TZ_1-A3.W1 | 0.0 | 0.00 | 0.00 | 0.00 | 10.73 | 7.74 | 4.05 | 1 | 1 | 1 | 8.45 | 13.00 | 6.40 | 9.15 | 2.70 | 5.40 | 2.70 | 29.19 | TARP | DOE-2 | 10.81 | 7.43 | 6.31 | 1.12 | 9 | 3 | 0 | Yes |
| 12 | TZ_1-A3.W2 | 0.0 | 0.00 | 0.00 | 0.00 | 10.73 | 5.06 | 4.05 | 1 | 1 | 1 | 8.45 | 13.00 | 3.65 | 6.40 | 2.70 | 5.40 | 2.70 | 29.19 | TARP | DOE-2 | 10.81 | 7.43 | 6.31 | 1.12 | 9 | 3 | 0 | Yes |
| 13 | TZ_1-H | 0.0 | 0.00 | 0.00 | 0.00 | 1.40 | 8.78 | 4.05 | 1 | 1 | 1 | 0.00 | 2.80 | 4.55 | 13.00 | 2.70 | 5.40 | 2.70 | 63.88 | TARP | DOE-2 | 23.66 | 30.38 | 28.14 | 2.24 | 6 | 2 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | TZ_0-A1.B | 19.22 | 0.5 | 35.324 | 2.831E-002 | 3.875 | 5.382 | 0.000 | 0.000 | 0.000 | 0.000 | 9.257 | No |
| 2 | TZ_0-A1.LK | 37.29 | 1.1 | 35.324 | 2.831E-002 | 3.875 | 5.382 | 0.000 | 0.000 | 0.000 | 0.000 | 9.257 | No |
| 3 | TZ_0-A1.W | 10.81 | 0.3 | 35.324 | 2.831E-002 | 3.875 | 5.382 | 0.000 | 0.000 | 0.000 | 0.000 | 9.257 | No |
| 4 | TZ_0-A2.B | 18.31 | 0.5 | 35.324 | 2.831E-002 | 3.875 | 5.382 | 0.000 | 0.000 | 0.000 | 0.000 | 9.257 | No |
| 5 | TZ_0-A2.LK | 48.90 | 1.4 | 35.324 | 2.831E-002 | 3.875 | 5.382 | 0.000 | 0.000 | 0.000 | 0.000 | 9.257 | No |
| 6 | TZ_0-A2.W | 10.81 | 0.3 | 35.324 | 2.831E-002 | 3.875 | 5.382 | 0.000 | 0.000 | 0.000 | 0.000 | 9.257 | No |
| 7 | TZ_0-H | 23.66 | 0.0 | N/A | 0.000 | 9.903 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9.903 | No |
| 8 | TZ_1-A3.B1 | 19.22 | 0.5 | 35.324 | 2.831E-002 | 3.875 | 5.382 | 0.000 | 0.000 | 0.000 | 0.000 | 9.257 | No |
| 9 | TZ_1-A3.B2 | 18.31 | 0.5 | 35.324 | 2.831E-002 | 3.875 | 5.382 | 0.000 | 0.000 | 0.000 | 0.000 | 9.257 | No |
| 10 | TZ_1-A3.LK | 86.19 | 2.4 | 35.324 | 2.831E-002 | 3.875 | 5.382 | 0.000 | 0.000 | 0.000 | 0.000 | 9.257 | No |
| 11 | TZ_1-A3.W1 | 10.81 | 0.3 | 35.324 | 2.831E-002 | 3.875 | 5.382 | 0.000 | 0.000 | 0.000 | 0.000 | 9.257 | No |
| 12 | TZ_1-A3.W2 | 10.81 | 0.3 | 35.324 | 2.831E-002 | 3.875 | 5.382 | 0.000 | 0.000 | 0.000 | 0.000 | 9.257 | No |
| 13 | TZ_1-H | 23.66 | 0.0 | N/A | 0.000 | 9.903 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9.903 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | 1-A3.B1 MIDRISEAPARTMENT APARTMENT PEOPLE | MIDRISEAPARTMENT APARTMENT OCC | TZ_1-A3.B1 | 19.22 | 0.5 | 0.5 | 2.831E-002 | 35.324 | 0.300 | 0.700 | AutoCalculate | MIDRISEAPARTMENT ACTIVITY | No | 3.8200E-008 | 0 | 1 |
| 2 | 0-A2.B MIDRISEAPARTMENT APARTMENT PEOPLE | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A2.B | 18.31 | 0.5 | 0.5 | 2.831E-002 | 35.324 | 0.300 | 0.700 | AutoCalculate | MIDRISEAPARTMENT ACTIVITY | No | 3.8200E-008 | 0 | 1 |
| 3 | 0-A1.LK MIDRISEAPARTMENT APARTMENT PEOPLE | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A1.LK | 37.29 | 1.1 | 1.1 | 2.831E-002 | 35.324 | 0.300 | 0.700 | AutoCalculate | MIDRISEAPARTMENT ACTIVITY | No | 3.8200E-008 | 0 | 1 |
| 4 | 0-A2.LK MIDRISEAPARTMENT APARTMENT PEOPLE | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A2.LK | 48.90 | 1.4 | 1.4 | 2.831E-002 | 35.324 | 0.300 | 0.700 | AutoCalculate | MIDRISEAPARTMENT ACTIVITY | No | 3.8200E-008 | 0 | 1 |
| 5 | 1-A3.W1 MIDRISEAPARTMENT APARTMENT PEOPLE | MIDRISEAPARTMENT APARTMENT OCC | TZ_1-A3.W1 | 10.81 | 0.3 | 0.3 | 2.831E-002 | 35.324 | 0.300 | 0.700 | AutoCalculate | MIDRISEAPARTMENT ACTIVITY | No | 3.8200E-008 | 8E-002 | 0 |
| 6 | 0-A1.B MIDRISEAPARTMENT APARTMENT PEOPLE | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A1.B | 19.22 | 0.5 | 0.5 | 2.831E-002 | 35.324 | 0.300 | 0.700 | AutoCalculate | MIDRISEAPARTMENT ACTIVITY | No | 3.8200E-008 | 0 | 1 |
| 7 | 0-A1.W MIDRISEAPARTMENT APARTMENT PEOPLE | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A1.W | 10.81 | 0.3 | 0.3 | 2.831E-002 | 35.324 | 0.300 | 0.700 | AutoCalculate | MIDRISEAPARTMENT ACTIVITY | No | 3.8200E-008 | 8E-002 | 0 |
| 8 | 0-A2.W MIDRISEAPARTMENT APARTMENT PEOPLE | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A2.W | 10.81 | 0.3 | 0.3 | 2.831E-002 | 35.324 | 0.300 | 0.700 | AutoCalculate | MIDRISEAPARTMENT ACTIVITY | No | 3.8200E-008 | 8E-002 | 0 |
| 9 | 1-A3.B2 MIDRISEAPARTMENT APARTMENT PEOPLE | MIDRISEAPARTMENT APARTMENT OCC | TZ_1-A3.B2 | 18.31 | 0.5 | 0.5 | 2.831E-002 | 35.324 | 0.300 | 0.700 | AutoCalculate | MIDRISEAPARTMENT ACTIVITY | No | 3.8200E-008 | 0 | 1 |
| 10 | 1-A3.LK MIDRISEAPARTMENT APARTMENT PEOPLE | MIDRISEAPARTMENT APARTMENT OCC | TZ_1-A3.LK | 86.19 | 2.4 | 2.4 | 2.831E-002 | 35.324 | 0.300 | 0.700 | AutoCalculate | MIDRISEAPARTMENT ACTIVITY | No | 3.8200E-008 | 1 | 2 |
| 11 | 1-A3.W2 MIDRISEAPARTMENT APARTMENT PEOPLE | MIDRISEAPARTMENT APARTMENT OCC | TZ_1-A3.W2 | 10.81 | 0.3 | 0.3 | 2.831E-002 | 35.324 | 0.300 | 0.700 | AutoCalculate | MIDRISEAPARTMENT ACTIVITY | No | 3.8200E-008 | 8E-002 | 0 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | 1-A3.B1 MIDRISEAPARTMENT APARTMENT LIGHTS | MIDRISEAPARTMENT APARTMENT LIGHT | TZ_1-A3.B1 | 19.22 | 0.5 | 74.468 | 3.875 | 136.882 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 4.989 | 74.468 |
| 2 | 0-A2.B MIDRISEAPARTMENT APARTMENT LIGHTS | MIDRISEAPARTMENT APARTMENT LIGHT | TZ_0-A2.B | 18.31 | 0.5 | 70.942 | 3.875 | 136.882 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 4.753 | 70.942 |
| 3 | 0-A1.LK MIDRISEAPARTMENT APARTMENT LIGHTS | MIDRISEAPARTMENT APARTMENT LIGHT | TZ_0-A1.LK | 37.29 | 1.1 | 144.499 | 3.875 | 136.882 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 9.681 | 144.499 |
| 4 | 0-A2.LK MIDRISEAPARTMENT APARTMENT LIGHTS | MIDRISEAPARTMENT APARTMENT LIGHT | TZ_0-A2.LK | 48.90 | 1.4 | 189.488 | 3.875 | 136.882 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 12.696 | 189.488 |
| 5 | 1-A3.W1 MIDRISEAPARTMENT APARTMENT LIGHTS | MIDRISEAPARTMENT APARTMENT LIGHT | TZ_1-A3.W1 | 10.81 | 0.3 | 41.899 | 3.875 | 136.882 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 2.807 | 41.899 |
| 6 | 0-A1.B MIDRISEAPARTMENT APARTMENT LIGHTS | MIDRISEAPARTMENT APARTMENT LIGHT | TZ_0-A1.B | 19.22 | 0.5 | 74.468 | 3.875 | 136.882 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 4.989 | 74.468 |
| 7 | 0-A1.W MIDRISEAPARTMENT APARTMENT LIGHTS | MIDRISEAPARTMENT APARTMENT LIGHT | TZ_0-A1.W | 10.81 | 0.3 | 41.899 | 3.875 | 136.882 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 2.807 | 41.899 |
| 8 | 0-A2.W MIDRISEAPARTMENT APARTMENT LIGHTS | MIDRISEAPARTMENT APARTMENT LIGHT | TZ_0-A2.W | 10.81 | 0.3 | 41.899 | 3.875 | 136.882 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 2.807 | 41.899 |
| 9 | 1-A3.B2 MIDRISEAPARTMENT APARTMENT LIGHTS | MIDRISEAPARTMENT APARTMENT LIGHT | TZ_1-A3.B2 | 18.31 | 0.5 | 70.942 | 3.875 | 136.882 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 4.753 | 70.942 |
| 10 | 1-A3.LK MIDRISEAPARTMENT APARTMENT LIGHTS | MIDRISEAPARTMENT APARTMENT LIGHT | TZ_1-A3.LK | 86.19 | 2.4 | 333.987 | 3.875 | 136.882 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 22.377 | 333.987 |
| 11 | 1-A3.W2 MIDRISEAPARTMENT APARTMENT LIGHTS | MIDRISEAPARTMENT APARTMENT LIGHT | TZ_1-A3.W2 | 10.81 | 0.3 | 41.899 | 3.875 | 136.882 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 2.807 | 41.899 |
| 12 | 0-H MIDRISEAPARTMENT CORRIDOR LIGHTS | MIDRISEAPARTMENT CORRIDOR LIGHT | TZ_0-H | 23.66 | 0.0 | 234.300 | 9.903 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 234.300 | 234.300 |
| 13 | 1-H MIDRISEAPARTMENT CORRIDOR LIGHTS | MIDRISEAPARTMENT CORRIDOR LIGHT | TZ_1-H | 23.66 | 0.0 | 234.300 | 9.903 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 234.300 | 234.300 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | 1-A3.B1 MIDRISEAPARTMENT APARTMENT ELEC EQUIP | APARTMENTMIDRISE EQP_APT_SCH | TZ_1-A3.B1 | 19.22 | 0.5 | 103.428 | 5.382 | 190.114 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.303 | 103.428 |
| 2 | 0-A2.B MIDRISEAPARTMENT APARTMENT ELEC EQUIP | APARTMENTMIDRISE EQP_APT_SCH | TZ_0-A2.B | 18.31 | 0.5 | 98.530 | 5.382 | 190.114 | 0.000 | 0.500 | 0.000 | 0.500 | General | 37.441 | 98.530 |
| 3 | 0-A1.LK MIDRISEAPARTMENT APARTMENT ELEC EQUIP | APARTMENTMIDRISE EQP_APT_SCH | TZ_0-A1.LK | 37.29 | 1.1 | 200.693 | 5.382 | 190.114 | 0.000 | 0.500 | 0.000 | 0.500 | General | 76.263 | 200.693 |
| 4 | 0-A2.LK MIDRISEAPARTMENT APARTMENT ELEC EQUIP | APARTMENTMIDRISE EQP_APT_SCH | TZ_0-A2.LK | 48.90 | 1.4 | 263.178 | 5.382 | 190.114 | 0.000 | 0.500 | 0.000 | 0.500 | General | 100.007 | 263.178 |
| 5 | 1-A3.W1 MIDRISEAPARTMENT APARTMENT ELEC EQUIP | APARTMENTMIDRISE EQP_APT_SCH | TZ_1-A3.W1 | 10.81 | 0.3 | 58.192 | 5.382 | 190.114 | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.113 | 58.192 |
| 6 | 0-A1.B MIDRISEAPARTMENT APARTMENT ELEC EQUIP | APARTMENTMIDRISE EQP_APT_SCH | TZ_0-A1.B | 19.22 | 0.5 | 103.428 | 5.382 | 190.114 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.303 | 103.428 |
| 7 | 0-A1.W MIDRISEAPARTMENT APARTMENT ELEC EQUIP | APARTMENTMIDRISE EQP_APT_SCH | TZ_0-A1.W | 10.81 | 0.3 | 58.192 | 5.382 | 190.114 | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.113 | 58.192 |
| 8 | 0-A2.W MIDRISEAPARTMENT APARTMENT ELEC EQUIP | APARTMENTMIDRISE EQP_APT_SCH | TZ_0-A2.W | 10.81 | 0.3 | 58.192 | 5.382 | 190.114 | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.113 | 58.192 |
| 9 | 1-A3.B2 MIDRISEAPARTMENT APARTMENT ELEC EQUIP | APARTMENTMIDRISE EQP_APT_SCH | TZ_1-A3.B2 | 18.31 | 0.5 | 98.530 | 5.382 | 190.114 | 0.000 | 0.500 | 0.000 | 0.500 | General | 37.441 | 98.530 |
| 10 | 1-A3.LK MIDRISEAPARTMENT APARTMENT ELEC EQUIP | APARTMENTMIDRISE EQP_APT_SCH | TZ_1-A3.LK | 86.19 | 2.4 | 463.871 | 5.382 | 190.114 | 0.000 | 0.500 | 0.000 | 0.500 | General | 176.271 | 463.871 |
| 11 | 1-A3.W2 MIDRISEAPARTMENT APARTMENT ELEC EQUIP | APARTMENTMIDRISE EQP_APT_SCH | TZ_1-A3.W2 | 10.81 | 0.3 | 58.192 | 5.382 | 190.114 | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.113 | 58.192 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | 1-A3.B1 MIDRISEAPARTMENT APARTMENT INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_1-A3.B1 | 19.22 | 0.5 | 2.569E-002 | 1.337E-003 | 6.132E-004 | 1.783 | 1.000 | 0.000 | 0.000 | 0.000 |
| 2 | 0-A2.B MIDRISEAPARTMENT APARTMENT INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_0-A2.B | 18.31 | 0.5 | 2.508E-002 | 1.370E-003 | 1.133E-003 | 1.827 | 1.000 | 0.000 | 0.000 | 0.000 |
| 3 | 0-A1.LK MIDRISEAPARTMENT APARTMENT INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_0-A1.LK | 37.29 | 1.1 | 1.728E-002 | 4.634E-004 | 1.133E-003 | 0.618 | 1.000 | 0.000 | 0.000 | 0.000 |
| 4 | 0-A2.LK MIDRISEAPARTMENT APARTMENT INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_0-A2.LK | 48.90 | 1.4 | 3.976E-002 | 8.131E-004 | 1.133E-003 | 1.084 | 1.000 | 0.000 | 0.000 | 0.000 |
| 5 | 1-A3.W1 MIDRISEAPARTMENT APARTMENT INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_1-A3.W1 | 10.81 | 0.3 | 8.411E-003 | 7.779E-004 | 4.612E-004 | 1.037 | 1.000 | 0.000 | 0.000 | 0.000 |
| 6 | 0-A1.B MIDRISEAPARTMENT APARTMENT INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_0-A1.B | 19.22 | 0.5 | 2.569E-002 | 1.337E-003 | 1.133E-003 | 1.783 | 1.000 | 0.000 | 0.000 | 0.000 |
| 7 | 0-A1.W MIDRISEAPARTMENT APARTMENT INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_0-A1.W | 10.81 | 0.3 | 8.411E-003 | 7.779E-004 | 1.133E-003 | 1.037 | 1.000 | 0.000 | 0.000 | 0.000 |
| 8 | 0-A2.W MIDRISEAPARTMENT APARTMENT INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_0-A2.W | 10.81 | 0.3 | 8.411E-003 | 7.779E-004 | 1.133E-003 | 1.037 | 1.000 | 0.000 | 0.000 | 0.000 |
| 9 | 1-A3.B2 MIDRISEAPARTMENT APARTMENT INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_1-A3.B2 | 18.31 | 0.5 | 2.508E-002 | 1.370E-003 | 6.201E-004 | 1.827 | 1.000 | 0.000 | 0.000 | 0.000 |
| 10 | 1-A3.LK MIDRISEAPARTMENT APARTMENT INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_1-A3.LK | 86.19 | 2.4 | 5.704E-002 | 6.618E-004 | 4.178E-004 | 0.882 | 1.000 | 0.000 | 0.000 | 0.000 |
| 11 | 1-A3.W2 MIDRISEAPARTMENT APARTMENT INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_1-A3.W2 | 10.81 | 0.3 | 8.411E-003 | 7.779E-004 | 4.612E-004 | 1.037 | 1.000 | 0.000 | 0.000 | 0.000 |
| 12 | 0-H MIDRISEAPARTMENT CORRIDOR INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_0-H | 23.66 | 0.0 | 3.441E-002 | 1.454E-003 | 1.133E-003 | 1.939 | 1.000 | 0.000 | 0.000 | 0.000 |
| 13 | 1-H MIDRISEAPARTMENT CORRIDOR INFILTRATION | MIDRISEAPARTMENT INFIL | TZ_1-H | 23.66 | 0.0 | 3.441E-002 | 1.454E-003 | 6.368E-004 | 1.939 | 1.000 | 0.000 | 0.000 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | TZ_0-A1.B VENTILATION PER PERSON | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A1.B | 19.22 | 0.5 | 9.243E-003 | 4.810E-004 | 1.699E-002 | 0.641 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -100.00 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
| 2 | TZ_0-A1.LK VENTILATION PER PERSON | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A1.LK | 37.29 | 1.1 | 1.794E-002 | 4.810E-004 | 1.699E-002 | 0.641 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -100.00 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
| 3 | TZ_0-A1.W VENTILATION PER PERSON | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A1.W | 10.81 | 0.3 | 5.201E-003 | 4.810E-004 | 1.699E-002 | 0.641 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -100.00 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
| 4 | TZ_0-A2.B VENTILATION PER PERSON | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A2.B | 18.31 | 0.5 | 8.805E-003 | 4.810E-004 | 1.699E-002 | 0.641 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -100.00 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
| 5 | TZ_0-A2.LK VENTILATION PER PERSON | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A2.LK | 48.90 | 1.4 | 2.352E-002 | 4.810E-004 | 1.699E-002 | 0.641 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -100.00 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
| 6 | TZ_0-A2.W VENTILATION PER PERSON | MIDRISEAPARTMENT APARTMENT OCC | TZ_0-A2.W | 10.81 | 0.3 | 5.201E-003 | 4.810E-004 | 1.699E-002 | 0.641 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -100.00 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
| 7 | TZ_1-A3.B1 VENTILATION PER PERSON | MIDRISEAPARTMENT APARTMENT OCC | TZ_1-A3.B1 | 19.22 | 0.5 | 9.243E-003 | 4.810E-004 | 1.699E-002 | 0.641 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -100.00 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
| 8 | TZ_1-A3.B2 VENTILATION PER PERSON | MIDRISEAPARTMENT APARTMENT OCC | TZ_1-A3.B2 | 18.31 | 0.5 | 8.805E-003 | 4.810E-004 | 1.699E-002 | 0.641 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -100.00 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
| 9 | TZ_1-A3.LK VENTILATION PER PERSON | MIDRISEAPARTMENT APARTMENT OCC | TZ_1-A3.LK | 86.19 | 2.4 | 4.146E-002 | 4.810E-004 | 1.699E-002 | 0.641 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -100.00 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
| 10 | TZ_1-A3.W1 VENTILATION PER PERSON | MIDRISEAPARTMENT APARTMENT OCC | TZ_1-A3.W1 | 10.81 | 0.3 | 5.201E-003 | 4.810E-004 | 1.699E-002 | 0.641 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -100.00 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
| 11 | TZ_1-A3.W2 VENTILATION PER PERSON | MIDRISEAPARTMENT APARTMENT OCC | TZ_1-A3.W2 | 10.81 | 0.3 | 5.201E-003 | 4.810E-004 | 1.699E-002 | 0.641 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -100.00 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | TZ_0-A1.B | Mixing/Well-Stirred |
| 2 | TZ_0-A1.LK | Mixing/Well-Stirred |
| 3 | TZ_0-A1.W | Mixing/Well-Stirred |
| 4 | TZ_0-A2.B | Mixing/Well-Stirred |
| 5 | TZ_0-A2.LK | Mixing/Well-Stirred |
| 6 | TZ_0-A2.W | Mixing/Well-Stirred |
| 7 | TZ_0-H | Mixing/Well-Stirred |
| 8 | TZ_1-A3.B1 | Mixing/Well-Stirred |
| 9 | TZ_1-A3.B2 | Mixing/Well-Stirred |
| 10 | TZ_1-A3.LK | Mixing/Well-Stirred |
| 11 | TZ_1-A3.W1 | Mixing/Well-Stirred |
| 12 | TZ_1-A3.W2 | Mixing/Well-Stirred |
| 13 | TZ_1-H | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUN PERIOD 1 | WeatherFileRunPeriod | 01/01/2006 | 12/31/2006 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | No | RunPeriod Object |
| NumberofWarmupDays | |
| 1 | 3 |
| Style | Unit Conversion | |
| 1 | HTML | None |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | TZ_0-A1.B | RunPeriod: RUN PERIOD 1 | 2.4671622769E-015 | 2.3038593314E-015 | Pass | Pass | 9.3256524140E-003 | 1.1639398930E-002 | Pass | Pass |
| 2 | TZ_0-A1.LK | RunPeriod: RUN PERIOD 1 | 2.1957744265E-015 | 2.2153688555E-015 | Pass | Pass | 1.2292895773E-002 | 1.9691712731E-002 | Pass | Pass |
| 3 | TZ_0-A1.W | RunPeriod: RUN PERIOD 1 | 2.4918338997E-015 | 2.1381914915E-015 | Pass | Pass | 1.1016289456E-002 | 1.5942180206E-002 | Pass | Pass |
| 4 | TZ_0-A2.B | RunPeriod: RUN PERIOD 1 | 3.0839528462E-015 | 2.3775816422E-015 | Pass | Pass | 1.2324202153E-002 | 1.3191382588E-002 | Pass | Pass |
| 5 | TZ_0-A2.LK | RunPeriod: RUN PERIOD 1 | 2.7385501274E-015 | 2.7043294872E-015 | Pass | Pass | 1.3538925531E-002 | 1.6126911657E-002 | Pass | Pass |
| 6 | TZ_0-A2.W | RunPeriod: RUN PERIOD 1 | 2.5165055225E-015 | 2.4368770162E-015 | Pass | Pass | 1.1849928890E-002 | 1.6113985281E-002 | Pass | Pass |
| 7 | TZ_0-H | RunPeriod: RUN PERIOD 1 | 4.6649055635E-002 | 3.8469743304E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 8 | TZ_1-A3.B1 | RunPeriod: RUN PERIOD 1 | 2.6151920136E-015 | 2.4408702627E-015 | Pass | Pass | 1.0835408551E-002 | 1.1619431411E-002 | Pass | Pass |
| 9 | TZ_1-A3.B2 | RunPeriod: RUN PERIOD 1 | 2.6645352591E-015 | 2.4592546852E-015 | Pass | Pass | 1.4474684870E-002 | 1.4944859816E-002 | Pass | Pass |
| 10 | TZ_1-A3.LK | RunPeriod: RUN PERIOD 1 | 1.9737298216E-015 | 2.0841315914E-015 | Pass | Pass | 1.5729701182E-002 | 1.7034593825E-002 | Pass | Pass |
| 11 | TZ_1-A3.W1 | RunPeriod: RUN PERIOD 1 | 2.7632217502E-015 | 2.3848668173E-015 | Pass | Pass | 1.3149491815E-002 | 1.5186955181E-002 | Pass | Pass |
| 12 | TZ_1-A3.W2 | RunPeriod: RUN PERIOD 1 | 2.9605947323E-015 | 2.4770112673E-015 | Pass | Pass | 1.4123446494E-002 | 1.5655607723E-002 | Pass | Pass |
| 13 | TZ_1-H | RunPeriod: RUN PERIOD 1 | 5.0526935180E-002 | 4.0963744290E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Report
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Annual Heat Emissions Summary| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 353.99 | 155.29 | 0.00 | 0.00 | 0.00 | 509.28 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7°C, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] | Danger (> 39.4°C, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| TZ_0-A1.B | 8755.67 | 4.33 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 8757.67 | 2.33 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 8757.00 | 3.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 8756.83 | 3.17 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 8758.83 | 1.17 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 8755.33 | 4.67 | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 8235.83 | 513.83 | 10.33 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 7565.17 | 1034.33 | 160.50 | 0.00 | 0.00 |
| Min | 7565.17 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 1034.33 | 160.50 | 0.00 | 0.00 |
| Average | 8626.33 | 120.53 | 13.14 | 0.00 | 0.00 |
| Sum | 112142.33 | 1566.83 | 170.83 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7°C, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] | Danger (> 39.4°C, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| TZ_0-A1.B | 3259.42 | 1.12 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 6324.86 | 1.94 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 1834.03 | 0.47 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 3105.29 | 0.85 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 8295.63 | 0.98 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 1833.83 | 0.68 | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 3260.53 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 3106.14 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 14623.41 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 1834.50 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 1834.50 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 14623.41 | 1.94 | 0.00 | 0.00 | 0.00 |
| Average | 3793.24 | 0.46 | 0.00 | 0.00 | 0.00 |
| Sum | 49312.14 | 6.03 | 0.00 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7°C, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] | Danger (> 39.4°C, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| TZ_0-A1.B | 8755.67 | 4.33 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 8757.67 | 2.33 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 8757.00 | 3.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 8756.83 | 3.17 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 8758.83 | 1.17 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 8755.33 | 4.67 | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 4.67 | 0.00 | 0.00 | 0.00 |
| Average | 7410.87 | 1.44 | 0.00 | 0.00 | 0.00 |
| Sum | 96341.33 | 18.67 | 0.00 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| TZ_0-A1.B | 7930.00 | 830.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 7828.50 | 931.50 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 7861.17 | 898.83 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 7824.67 | 935.33 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 7796.00 | 964.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 7823.83 | 936.17 | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 7514.33 | 1244.67 | 1.00 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 7682.83 | 1077.17 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 7702.17 | 1057.83 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 7643.67 | 1116.33 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 7644.00 | 1116.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 7653.67 | 1106.33 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 7041.33 | 1677.33 | 41.33 | 0.00 | 0.00 |
| Min | 7041.33 | 830.00 | 0.00 | 0.00 | 0.00 |
| Max | 7930.00 | 1677.33 | 41.33 | 0.00 | 0.00 |
| Average | 7688.17 | 1068.58 | 3.26 | 0.00 | 0.00 |
| Sum | 99946.17 | 13891.50 | 42.33 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| TZ_0-A1.B | 2978.23 | 282.31 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 5666.55 | 660.25 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 1660.48 | 174.03 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 2812.10 | 294.04 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 7455.36 | 841.25 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 1653.94 | 180.56 | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 2897.65 | 362.89 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 2759.55 | 346.59 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 12859.06 | 1764.36 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 1608.34 | 226.16 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 1608.16 | 226.35 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 12859.06 | 1764.36 | 0.00 | 0.00 | 0.00 |
| Average | 3381.49 | 412.21 | 0.00 | 0.00 | 0.00 |
| Sum | 43959.40 | 5358.77 | 0.00 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| TZ_0-A1.B | 7930.00 | 830.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 7828.50 | 931.50 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 7861.17 | 898.83 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 7824.67 | 935.33 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 7796.00 | 964.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 7823.83 | 936.17 | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 7682.83 | 1077.17 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 7702.17 | 1057.83 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 7643.67 | 1116.33 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 7644.00 | 1116.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 7653.67 | 1106.33 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 7930.00 | 1116.33 | 0.00 | 0.00 | 0.00 |
| Average | 6568.50 | 843.81 | 0.00 | 0.00 | 0.00 |
| Sum | 85390.50 | 10969.50 | 0.00 | 0.00 | 0.00 |
| Hours of Safety [hr] | End Time of the Safety Duration | Safe Temperature Exceedance Hours [hr] | Safe Temperature Exceedance OccupantHours [hr] | Safe Temperature Exceedance OccupiedHours [hr] | |
| TZ_0-A1.B | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 0.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| Average | 7412.31 | - | 0.00 | 0.00 | 0.00 |
| Sum | 96360.00 | - | 0.00 | 0.00 | 0.00 |
| Hours of Safety [hr] | End Time of the Safety Duration | Safe Temperature Exceedance Hours [hr] | Safe Temperature Exceedance OccupantHours [hr] | Safe Temperature Exceedance OccupiedHours [hr] | |
| TZ_0-A1.B | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 0.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| Average | 7412.31 | - | 0.00 | 0.00 | 0.00 |
| Sum | 96360.00 | - | 0.00 | 0.00 | 0.00 |
| Cooling Setpoint Unmet Degree-Hours [°C·hr] | Cooling Setpoint Unmet Occupant-Weighted Degree-Hours [°C·hr] | Cooling Setpoint Unmet Occupied Degree-Hours [°C·hr] | Heating Setpoint Unmet Degree-Hours [°C·hr] | Heating Setpoint Unmet Occupant-Weighted Degree-Hours [°C·hr] | Heating Setpoint Unmet Occupied Degree-Hours [°C·hr] | |
| TZ_0-A1.B | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Sum | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Very-cold Exceedance OccupantHours [hr] | Cool Exceedance OccupantHours [hr] | Warm Exceedance OccupantHours [hr] | Very-hot Exceedance OccupantHours [hr] | |
| TZ_0-A1.B | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 0.00 | 0.00 | 0.00 | 0.00 |
| Average | 0.00 | 0.00 | 0.00 | 0.00 |
| Sum | 0.00 | 0.00 | 0.00 | 0.00 |
| Very-cold Exceedance OccupantHours [hr] | Cool Exceedance OccupantHours [hr] | Warm Exceedance OccupantHours [hr] | Very-hot Exceedance OccupantHours [hr] | |
| TZ_0-A1.B | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 0.00 | 0.00 | 0.00 | 0.00 |
| Average | 0.00 | 0.00 | 0.00 | 0.00 |
| Sum | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| None |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 70.00 | 68 | |||
| Feb | 44.00 | 44 | |||
| Mar | 52.00 | 47 | |||
| Apr | 102.00 | 95 | |||
| May | 96.00 | 90 | |||
| Jun | 46.00 | 46 | |||
| Jul | 24.00 | 24 | |||
| Aug | 42.00 | 42 | |||
| Sep | 12.00 | 12 | |||
| Oct | 60.00 | 58 | |||
| Nov | 98.00 | 89 | |||
| Dec | 14.00 | 14 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| FACE 23 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 12.29 | 10.05 | 0.00 | 90.00 | N |
| FACE 25 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 10.39 | 10.39 | 90.00 | 90.00 | E |
| FACE 20 | TYPICAL INSULATED CARPETED 6IN SLAB FLOOR | 0.30 | 2.250 | 3.540 | 19.22 | 19.22 | 180.00 | 180.00 | |
| FACE 18 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 15.25 | 11.89 | 0.00 | 90.00 | N |
| FACE 10 | TYPICAL INSULATED CARPETED 6IN SLAB FLOOR | 0.30 | 2.250 | 3.540 | 37.29 | 37.29 | 270.00 | 180.00 | |
| FACE 39 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 7.43 | 6.31 | 90.00 | 90.00 | E |
| FACE 30 | TYPICAL INSULATED CARPETED 6IN SLAB FLOOR | 0.30 | 2.250 | 3.540 | 10.81 | 10.81 | 90.00 | 180.00 | |
| FACE 76 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 9.86 | 9.86 | 90.00 | 90.00 | E |
| FACE 77 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 12.29 | 10.05 | 180.00 | 90.00 | S |
| FACE 68 | TYPICAL INSULATED CARPETED 6IN SLAB FLOOR | 0.30 | 2.250 | 3.540 | 18.31 | 18.31 | 90.00 | 180.00 | |
| FACE 44 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 12.29 | 10.04 | 270.00 | 90.00 | W |
| FACE 54 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 22.82 | 19.46 | 180.00 | 90.00 | S |
| FACE 42 | TYPICAL INSULATED CARPETED 6IN SLAB FLOOR | 0.30 | 2.250 | 3.540 | 48.90 | 48.90 | 180.00 | 180.00 | |
| FACE 65 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 7.43 | 6.31 | 90.00 | 90.00 | E |
| FACE 56 | TYPICAL INSULATED CARPETED 6IN SLAB FLOOR | 0.30 | 2.250 | 3.540 | 10.81 | 10.81 | 0.00 | 180.00 | |
| FACE 7 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 22.82 | 17.06 | 270.00 | 90.00 | W |
| FACE 9 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 7.56 | 7.56 | 0.00 | 90.00 | N |
| FACE 0 | TYPICAL INSULATED CARPETED 6IN SLAB FLOOR | 0.30 | 2.250 | 3.540 | 23.66 | 23.66 | 270.00 | 180.00 | |
| FACE 110 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 12.29 | 10.05 | 0.00 | 90.00 | N |
| FACE 112 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 10.39 | 10.39 | 90.00 | 90.00 | E |
| FACE 107 | TYPICAL IEAD ROOF R-17.24 10 | 0.30 | 0.329 | 0.345 | 19.22 | 19.22 | 180.00 | 0.00 | |
| FACE 149 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 9.86 | 9.86 | 90.00 | 90.00 | E |
| FACE 150 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 12.29 | 10.05 | 180.00 | 90.00 | S |
| FACE 142 | TYPICAL IEAD ROOF R-17.24 10 | 0.30 | 0.329 | 0.345 | 18.31 | 18.31 | 0.00 | 0.00 | |
| FACE 104 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 22.82 | 19.46 | 180.00 | 90.00 | S |
| FACE 89 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 12.29 | 10.05 | 270.00 | 90.00 | W |
| FACE 94 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 15.25 | 11.89 | 0.00 | 90.00 | N |
| FACE 88 | TYPICAL IEAD ROOF R-17.24 10 | 0.30 | 0.329 | 0.345 | 86.19 | 86.19 | 90.00 | 0.00 | |
| FACE 126 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 7.43 | 6.31 | 90.00 | 90.00 | E |
| FACE 118 | TYPICAL IEAD ROOF R-17.24 10 | 0.30 | 0.329 | 0.345 | 10.81 | 10.81 | 0.00 | 0.00 | |
| FACE 138 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 7.43 | 6.31 | 90.00 | 90.00 | E |
| FACE 130 | TYPICAL IEAD ROOF R-17.24 10 | 0.30 | 0.329 | 0.345 | 10.81 | 10.81 | 0.00 | 0.00 | |
| FACE 84 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 22.82 | 20.58 | 270.00 | 90.00 | W |
| FACE 86 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 | 0.30 | 0.505 | 0.547 | 7.56 | 7.56 | 0.00 | 90.00 | N |
| FACE 80 | TYPICAL IEAD ROOF R-17.24 10 | 0.30 | 0.329 | 0.345 | 23.66 | 23.66 | 180.00 | 0.00 |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| FACE 22 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 13.10 | 13.10 | 270.00 | 90.00 | W |
| FACE 26 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 180.00 | 90.00 | S |
| FACE 27 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 90.00 | 90.00 | E |
| FACE 28 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 2.91 | 180.00 | 90.00 | S |
| FACE 21 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 19.22 | 19.22 | 180.00 | 0.00 | |
| FACE 12 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 13.10 | 13.10 | 90.00 | 90.00 | E |
| FACE 13 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.73 | 3.05 | 90.00 | 90.00 | E |
| FACE 15 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 15.25 | 15.25 | 180.00 | 90.00 | S |
| FACE 16 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 17.82 | 15.93 | 270.00 | 90.00 | W |
| FACE 11 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 37.29 | 37.29 | 0.00 | 0.00 | |
| FACE 32 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 4.59 | 180.00 | 90.00 | S |
| FACE 33 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.73 | 3.05 | 270.00 | 90.00 | W |
| FACE 35 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 2.91 | 0.00 | 90.00 | N |
| FACE 37 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 270.00 | 90.00 | W |
| FACE 38 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 0.00 | 90.00 | N |
| FACE 41 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 180.00 | 90.00 | S |
| FACE 31 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 10.81 | 10.81 | 0.00 | 0.00 | |
| FACE 70 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 9.86 | 9.86 | 270.00 | 90.00 | W |
| FACE 71 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 270.00 | 90.00 | W |
| FACE 72 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 2.91 | 0.00 | 90.00 | N |
| FACE 74 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 90.00 | 90.00 | E |
| FACE 75 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 0.00 | 90.00 | N |
| FACE 69 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.31 | 18.31 | 0.00 | 0.00 | |
| FACE 46 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.56 | 7.56 | 0.00 | 90.00 | N |
| FACE 47 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 5.00 | 3.11 | 270.00 | 90.00 | W |
| FACE 49 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 15.25 | 15.25 | 0.00 | 90.00 | N |
| FACE 50 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.73 | 3.05 | 90.00 | 90.00 | E |
| FACE 52 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 90.00 | 90.00 | E |
| FACE 53 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 9.86 | 9.86 | 90.00 | 90.00 | E |
| FACE 43 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 48.90 | 48.90 | 0.00 | 0.00 | |
| FACE 58 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 270.00 | 90.00 | W |
| FACE 59 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 2.91 | 180.00 | 90.00 | S |
| FACE 61 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.73 | 3.05 | 270.00 | 90.00 | W |
| FACE 63 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 4.59 | 0.00 | 90.00 | N |
| FACE 64 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 0.00 | 90.00 | N |
| FACE 67 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 180.00 | 90.00 | S |
| FACE 57 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 10.81 | 10.81 | 0.00 | 0.00 | |
| FACE 2 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 17.82 | 15.93 | 90.00 | 90.00 | E |
| FACE 4 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 5.00 | 3.11 | 90.00 | 90.00 | E |
| FACE 6 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.56 | 7.56 | 180.00 | 90.00 | S |
| FACE 1 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 23.66 | 23.66 | 0.00 | 0.00 | |
| FACE 108 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 270.00 | 90.00 | W |
| FACE 109 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 10.39 | 10.39 | 270.00 | 90.00 | W |
| FACE 113 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 180.00 | 90.00 | S |
| FACE 114 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 90.00 | 90.00 | E |
| FACE 115 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 2.91 | 180.00 | 90.00 | S |
| FACE 106 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 19.22 | 19.22 | 0.00 | 180.00 | |
| FACE 143 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 9.86 | 9.86 | 270.00 | 90.00 | W |
| FACE 144 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 270.00 | 90.00 | W |
| FACE 145 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 2.91 | 0.00 | 90.00 | N |
| FACE 147 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 90.00 | 90.00 | E |
| FACE 148 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 0.00 | 90.00 | N |
| FACE 141 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.31 | 18.31 | 180.00 | 180.00 | |
| FACE 100 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.73 | 3.05 | 90.00 | 90.00 | E |
| FACE 102 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 90.00 | 90.00 | E |
| FACE 103 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 9.86 | 9.86 | 90.00 | 90.00 | E |
| FACE 91 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.56 | 7.56 | 0.00 | 90.00 | N |
| FACE 92 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 22.82 | 20.93 | 270.00 | 90.00 | W |
| FACE 96 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 10.39 | 10.39 | 90.00 | 90.00 | E |
| FACE 97 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 90.00 | 90.00 | E |
| FACE 98 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.73 | 3.05 | 90.00 | 90.00 | E |
| FACE 87 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 37.29 | 37.29 | 0.00 | 180.00 | |
| SURFACE 1 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 48.90 | 48.90 | 0.00 | 180.00 | |
| FACE 119 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 4.59 | 180.00 | 90.00 | S |
| FACE 120 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.73 | 3.05 | 270.00 | 90.00 | W |
| FACE 122 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 2.91 | 0.00 | 90.00 | N |
| FACE 124 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 270.00 | 90.00 | W |
| FACE 125 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 0.00 | 90.00 | N |
| FACE 128 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 180.00 | 90.00 | S |
| FACE 117 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 10.81 | 10.81 | 0.00 | 180.00 | |
| FACE 131 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 2.70 | 2.70 | 270.00 | 90.00 | W |
| FACE 132 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 2.91 | 180.00 | 90.00 | S |
| FACE 134 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.73 | 3.05 | 270.00 | 90.00 | W |
| FACE 136 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 4.59 | 4.59 | 0.00 | 90.00 | N |
| FACE 137 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 0.00 | 90.00 | N |
| FACE 140 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.69 | 7.69 | 180.00 | 90.00 | S |
| FACE 129 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 10.81 | 10.81 | 0.00 | 180.00 | |
| FACE 81 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 22.82 | 20.93 | 90.00 | 90.00 | E |
| FACE 83 | TYPICAL INTERIOR WALL | 0.30 | 2.511 | 6.300 | 7.56 | 7.56 | 180.00 | 90.00 | S |
| FACE 79 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 23.66 | 23.66 | 0.00 | 180.00 |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| FACE 24 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 2.24 | 0.00 | 0.00 | 2.24 | 2.24 | 3.354 | 0.361 | 0.271 | No | FACE 23 | 0.00 | 90.00 | N | |||||||
| FACE 19 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 3.354 | 0.361 | 0.271 | No | FACE 18 | 0.00 | 90.00 | N | |||||||
| FACE 40 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 1.12 | 0.00 | 0.00 | 1.12 | 1.12 | 3.354 | 0.361 | 0.271 | No | FACE 39 | 90.00 | 90.00 | E | |||||||
| FACE 78 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 2.24 | 0.00 | 0.00 | 2.24 | 2.24 | 3.354 | 0.361 | 0.271 | No | FACE 77 | 180.00 | 90.00 | S | |||||||
| FACE 45 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 2.24 | 0.00 | 0.00 | 2.24 | 2.24 | 3.354 | 0.361 | 0.271 | No | FACE 44 | 270.00 | 90.00 | W | |||||||
| FACE 55 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 3.354 | 0.361 | 0.271 | No | FACE 54 | 180.00 | 90.00 | S | |||||||
| FACE 66 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 1.12 | 0.00 | 0.00 | 1.12 | 1.12 | 3.354 | 0.361 | 0.271 | No | FACE 65 | 90.00 | 90.00 | E | |||||||
| FACE 8 | U 0.88 SHGC 0.16 SGL REF-A-L CLR 6MM | 5.76 | 0.00 | 0.00 | 5.76 | 5.76 | 4.440 | 0.202 | 0.080 | No | FACE 7 | 270.00 | 90.00 | W | |||||||
| FACE 111 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 2.24 | 0.00 | 0.00 | 2.24 | 2.24 | 3.354 | 0.361 | 0.271 | No | FACE 110 | 0.00 | 90.00 | N | |||||||
| FACE 151 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 2.24 | 0.00 | 0.00 | 2.24 | 2.24 | 3.354 | 0.361 | 0.271 | No | FACE 150 | 180.00 | 90.00 | S | |||||||
| FACE 105 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 3.354 | 0.361 | 0.271 | No | FACE 104 | 180.00 | 90.00 | S | |||||||
| FACE 90 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 2.24 | 0.00 | 0.00 | 2.24 | 2.24 | 3.354 | 0.361 | 0.271 | No | FACE 89 | 270.00 | 90.00 | W | |||||||
| FACE 95 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 3.354 | 0.361 | 0.271 | No | FACE 94 | 0.00 | 90.00 | N | |||||||
| FACE 127 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 1.12 | 0.00 | 0.00 | 1.12 | 1.12 | 3.354 | 0.361 | 0.271 | No | FACE 126 | 90.00 | 90.00 | E | |||||||
| FACE 139 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 1.12 | 0.00 | 0.00 | 1.12 | 1.12 | 3.354 | 0.361 | 0.271 | No | FACE 138 | 90.00 | 90.00 | E | |||||||
| FACE 85 | U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23 | 2.24 | 0.00 | 0.00 | 2.24 | 2.24 | 3.354 | 0.361 | 0.271 | No | FACE 84 | 270.00 | 90.00 | W | |||||||
| Total or Average | 39.36 | 3.513 | 0.338 | 0.243 | |||||||||||||||||
| North Total or Average | 11.20 | 3.354 | 0.361 | 0.271 | |||||||||||||||||
| Non-North Total or Average | 28.16 | 3.577 | 0.329 | 0.232 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| FACE 29 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 28 |
| FACE 14 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 13 |
| FACE 17 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.89 | FACE 16 |
| FACE 34 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 33 |
| FACE 36 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 35 |
| FACE 73 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 72 |
| FACE 48 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.89 | FACE 47 |
| FACE 51 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 50 |
| FACE 60 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 59 |
| FACE 62 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 61 |
| FACE 3 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.89 | FACE 2 |
| FACE 5 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.89 | FACE 4 |
| FACE 116 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 115 |
| FACE 146 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 145 |
| FACE 101 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 100 |
| FACE 93 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.89 | FACE 92 |
| FACE 99 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 98 |
| FACE 121 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 120 |
| FACE 123 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 122 |
| FACE 133 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 132 |
| FACE 135 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.68 | FACE 134 |
| FACE 82 | TYPICAL INTERIOR DOOR | 2.446 | 5.906 | 1.89 | FACE 81 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| FACE 24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| FACE 19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| FACE 40 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| FACE 78 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| FACE 45 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| FACE 55 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| FACE 66 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| FACE 8 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| FACE 111 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| FACE 151 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| FACE 105 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| FACE 90 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| FACE 95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| FACE 127 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| FACE 139 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| FACE 85 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| 1-A3.B1 MIDRISEAPARTMENT APARTMENT LIGHTS | TZ_1-A3.B1 | 1-A3.B1 | MIDRISEAPARTMENT APARTMENT | 3.8750 | 19.22 | 74.47 | General | MIDRISEAPARTMENT APARTMENT LIGHT | 55.16 | 168.00 | 55.16 | 0.0000 | Y | 0.77 |
| 0-A2.B MIDRISEAPARTMENT APARTMENT LIGHTS | TZ_0-A2.B | 0-A2.B | MIDRISEAPARTMENT APARTMENT | 3.8750 | 18.31 | 70.94 | General | MIDRISEAPARTMENT APARTMENT LIGHT | 55.16 | 168.00 | 55.16 | 0.0000 | Y | 0.73 |
| 0-A1.LK MIDRISEAPARTMENT APARTMENT LIGHTS | TZ_0-A1.LK | 0-A1.LK | MIDRISEAPARTMENT APARTMENT | 3.8750 | 37.29 | 144.50 | General | MIDRISEAPARTMENT APARTMENT LIGHT | 55.16 | 168.00 | 55.16 | 0.0000 | Y | 1.50 |
| 0-A2.LK MIDRISEAPARTMENT APARTMENT LIGHTS | TZ_0-A2.LK | 0-A2.LK | MIDRISEAPARTMENT APARTMENT | 3.8750 | 48.90 | 189.49 | General | MIDRISEAPARTMENT APARTMENT LIGHT | 55.16 | 168.00 | 55.16 | 0.0000 | Y | 1.96 |
| 1-A3.W1 MIDRISEAPARTMENT APARTMENT LIGHTS | TZ_1-A3.W1 | 1-A3.W1 | MIDRISEAPARTMENT APARTMENT | 3.8750 | 10.81 | 41.90 | General | MIDRISEAPARTMENT APARTMENT LIGHT | 55.16 | 168.00 | 55.16 | 0.0000 | Y | 0.43 |
| 0-A1.B MIDRISEAPARTMENT APARTMENT LIGHTS | TZ_0-A1.B | 0-A1.B | MIDRISEAPARTMENT APARTMENT | 3.8750 | 19.22 | 74.47 | General | MIDRISEAPARTMENT APARTMENT LIGHT | 55.16 | 168.00 | 55.16 | 0.0000 | Y | 0.77 |
| 0-A1.W MIDRISEAPARTMENT APARTMENT LIGHTS | TZ_0-A1.W | 0-A1.W | MIDRISEAPARTMENT APARTMENT | 3.8750 | 10.81 | 41.90 | General | MIDRISEAPARTMENT APARTMENT LIGHT | 55.16 | 168.00 | 55.16 | 0.0000 | Y | 0.43 |
| 0-A2.W MIDRISEAPARTMENT APARTMENT LIGHTS | TZ_0-A2.W | 0-A2.W | MIDRISEAPARTMENT APARTMENT | 3.8750 | 10.81 | 41.90 | General | MIDRISEAPARTMENT APARTMENT LIGHT | 55.16 | 168.00 | 55.16 | 0.0000 | Y | 0.43 |
| 1-A3.B2 MIDRISEAPARTMENT APARTMENT LIGHTS | TZ_1-A3.B2 | 1-A3.B2 | MIDRISEAPARTMENT APARTMENT | 3.8750 | 18.31 | 70.94 | General | MIDRISEAPARTMENT APARTMENT LIGHT | 55.16 | 168.00 | 55.16 | 0.0000 | Y | 0.73 |
| 1-A3.LK MIDRISEAPARTMENT APARTMENT LIGHTS | TZ_1-A3.LK | 1-A3.LK | MIDRISEAPARTMENT APARTMENT | 3.8750 | 86.19 | 333.99 | General | MIDRISEAPARTMENT APARTMENT LIGHT | 55.16 | 168.00 | 55.16 | 0.0000 | Y | 3.46 |
| 1-A3.W2 MIDRISEAPARTMENT APARTMENT LIGHTS | TZ_1-A3.W2 | 1-A3.W2 | MIDRISEAPARTMENT APARTMENT | 3.8750 | 10.81 | 41.90 | General | MIDRISEAPARTMENT APARTMENT LIGHT | 55.16 | 168.00 | 55.16 | 0.0000 | Y | 0.43 |
| 0-H MIDRISEAPARTMENT CORRIDOR LIGHTS | TZ_0-H | 0-H | MIDRISEAPARTMENT CORRIDOR | 9.9028 | 23.66 | 234.30 | General | MIDRISEAPARTMENT CORRIDOR LIGHT | 168.00 | 168.00 | 168.00 | 0.0000 | N | 7.39 |
| 1-H MIDRISEAPARTMENT CORRIDOR LIGHTS | TZ_1-H | 1-H | MIDRISEAPARTMENT CORRIDOR | 9.9028 | 23.66 | 234.30 | General | MIDRISEAPARTMENT CORRIDOR LIGHT | 168.00 | 168.00 | 168.00 | 0.0000 | N | 7.39 |
| Interior Lighting Total | 4.7189 | 338.00 | 1594.99 | 26.44 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| Exterior Lighting Total | 0.00 | 0.00 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| None |
| Cooling Coil Type #1 | Standard Rated Net Cooling Capacity [W] #2 | Standard Rated Net COP [W/W] #2 | EER [Btu/W-h] #2 | SEER User [Btu/W-h] #2,3 | SEER Standard [Btu/W-h] #2,3 | IEER [Btu/W-h] #2 | |
| None |
| Cooling Coil Type #1 | Standard Rated Net Cooling Capacity [W] #2 | Standard Rated Net COP [W/W] #2,4 | EER [Btu/W-h] #2,4 | SEER User [Btu/W-h] #2,3 | SEER Standard [Btu/W-h] #2,3 | IEER [Btu/W-h] #2 | |
| None |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| None |
| Coil Type | Rated Total Capacity [W] | Rated Sensible Capacity [W] | Rated Power[W] | Rated COP [W/W] | Rated Air Dry-bulb Temperature [C] | Rated Air Wet-bulb Temperature [C] | Rated Water Temperature [C] | Design Day used for Sizing | |
| None |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | Minimum Outdoor Dry-Bulb Temperature for Compressor Operation | Airloop Name | |
| None |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF2 [Btu/W-h] | Region Number | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | Used as Supplementary Heat | Airloop Name | Plantloop Name | |
| None |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | Purpose | Is Autosized | Motor Efficiency | Motor Heat to Zone Fraction | Airloop Name | |
| None |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | Is Autosized | Plantloop Name | Plantloop Branch Name | |
| None |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| None |
| Type | Reference Capacity[W] | TypeReference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | Minimum Part Load Ratio | Fuel Type | Rated Entering Condenser Temperature [C] | Rated Leaving Evaporator Temperature [C] | Reference Entering Condenser Temperature [C] | Reference Leaving Evaporator Temperature [C] | Design Size Reference Chilled Water Flow Rate [kg/s] | Design Size Reference Condenser Fluid Flow Rate [kg/s] | Plantloop Name | Plantloop Branch Name | Condenser Loop Name | Condenser Loop Branch Name | Heat Recovery Plantloop Name | Heat Recovery Plantloop Branch Name | Recovery Relative Capacity Fraction | |
| None |
| Type | Reference Capacity [W] | Reference Efficiency[W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | Minimum Part Load Ratio | Fuel Type | Parasitic Electric Load [W] | Plantloop Name | Plantloop Branch Name | |
| None |
| Type | Fluid Type | Range [C] | Approach [C] | Design Fan Power [W] | Design Inlet Air Wet-Bulb Temperature [C] | Design Water Flow Rate [m3/s] | Leaving Water Setpoint Temperature [C] | Condenser Loop Name | Condenser Loop Branch Name | |
| None |
| Type | Provides Heating | Provides Cooling | Maximum Loop Flow Rate [m3/s] | Minimum Loop Flow Rate [m3/s] | |
| None |
| Zone Name | Minimum Flow [m3/s] | Minimum Outdoor Flow [m3/s] | Supply Cooling Setpoint [C] | Supply Heating Setpoint [C] | Heating Capacity [W] | Cooling Capacity [W] | |
| None |
| Name | Input object type | Plate/Rotary | Sensible Effectiveness at 100% Heating Air Flow | Sensible Effectiveness at 100% Cooling Air Flow | Latent Effectiveness at 100% Heating Air Flow | Latent Effectiveness at 100% Cooling Air Flow | Exhaust Airflow [kg/s] | Outdoor Airflow [kg/s] | |
| None |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Space Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| None |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| None |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| None |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| None |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| None |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| None |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| None |
| Coil Name | Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | Supply Fan Name for HVAC | Supply Fan Type for HVAC | Airloop Name | Plant Name for Coil | Plant Loop Name | |
| None |
Report: System Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| TZ_0-A1.B | 6936.17 | 8463.33 | 6720.67 |
| TZ_0-A1.LK | 6858.83 | 8506.83 | 6676.83 |
| TZ_0-A1.W | 6769.67 | 8435.50 | 6547.50 |
| TZ_0-A2.B | 6809.67 | 8201.67 | 6373.33 |
| TZ_0-A2.LK | 6839.50 | 8272.50 | 6463.67 |
| TZ_0-A2.W | 6724.00 | 8370.00 | 6445.67 |
| TZ_1-A3.B1 | 7268.33 | 7788.17 | 6382.83 |
| TZ_1-A3.B2 | 7161.33 | 7765.00 | 6278.50 |
| TZ_1-A3.LK | 7242.33 | 7722.00 | 6313.50 |
| TZ_1-A3.W1 | 7162.50 | 7540.83 | 6048.50 |
| TZ_1-A3.W2 | 7142.00 | 7501.67 | 5998.50 |
| TZ_0-H | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 0.00 | 0.00 | 0.00 |
| Facility | 7930.33 | 8632.83 | 7123.67 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| TZ_0-A1.B | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.LK | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A1.W | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.B | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.LK | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-A2.W | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B1 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-H | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| TZ_0-A1.B | 0.37 | 0.54 | 51.89 | 0.000 | 1.841 | 0.000 | 0.455 |
| TZ_0-A1.LK | 0.72 | 1.06 | 100.68 | 0.000 | 0.639 | 0.000 | 0.455 |
| TZ_0-A1.W | 0.21 | 0.31 | 29.19 | 0.000 | 1.072 | 0.000 | 0.455 |
| TZ_0-A2.B | 0.35 | 0.52 | 49.43 | 0.000 | 1.888 | 0.000 | 0.455 |
| TZ_0-A2.LK | 0.95 | 1.38 | 132.03 | 0.000 | 1.121 | 0.000 | 0.455 |
| TZ_0-A2.W | 0.21 | 0.31 | 29.19 | 0.000 | 1.072 | 0.000 | 0.455 |
| TZ_1-A3.B1 | 0.37 | 0.54 | 51.89 | 0.000 | 1.844 | 0.000 | 0.456 |
| TZ_1-A3.B2 | 0.35 | 0.52 | 49.43 | 0.000 | 1.890 | 0.000 | 0.456 |
| TZ_1-A3.LK | 1.67 | 2.44 | 232.71 | 0.000 | 0.913 | 0.000 | 0.456 |
| TZ_1-A3.W1 | 0.21 | 0.31 | 29.19 | 0.000 | 1.074 | 0.000 | 0.456 |
| TZ_1-A3.W2 | 0.21 | 0.31 | 29.19 | 0.000 | 1.074 | 0.000 | 0.456 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| TZ_0-A1.B | 0.37 | 0.54 | 51.89 | 0.000 | 0.098 | 0.000 | 0.011 |
| TZ_0-A1.LK | 0.72 | 1.06 | 100.68 | 0.000 | 0.034 | 0.000 | 0.011 |
| TZ_0-A1.W | 0.21 | 0.31 | 29.19 | 0.000 | 0.057 | 0.000 | 0.011 |
| TZ_0-A2.B | 0.35 | 0.52 | 49.43 | 0.000 | 0.101 | 0.000 | 0.011 |
| TZ_0-A2.LK | 0.95 | 1.38 | 132.03 | 0.000 | 0.060 | 0.000 | 0.011 |
| TZ_0-A2.W | 0.21 | 0.31 | 29.19 | 0.000 | 0.057 | 0.000 | 0.011 |
| TZ_1-A3.B1 | 0.37 | 0.54 | 51.89 | 0.000 | 0.099 | 0.000 | 0.011 |
| TZ_1-A3.B2 | 0.35 | 0.52 | 49.43 | 0.000 | 0.102 | 0.000 | 0.011 |
| TZ_1-A3.LK | 1.67 | 2.44 | 232.71 | 0.000 | 0.049 | 0.000 | 0.011 |
| TZ_1-A3.W1 | 0.21 | 0.31 | 29.19 | 0.000 | 0.058 | 0.000 | 0.011 |
| TZ_1-A3.W2 | 0.21 | 0.31 | 29.19 | 0.000 | 0.058 | 0.000 | 0.011 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| TZ_0-A1.B | 0.37 | 0.54 | 51.89 | 19.22 | 0.000 | ||
| TZ_0-A1.LK | 0.72 | 1.06 | 100.68 | 37.29 | 0.000 | ||
| TZ_0-A1.W | 0.21 | 0.31 | 29.19 | 10.81 | 0.000 | ||
| TZ_0-A2.B | 0.35 | 0.52 | 49.43 | 18.31 | 0.000 | ||
| TZ_0-A2.LK | 0.95 | 1.38 | 132.03 | 48.90 | 0.000 | ||
| TZ_0-A2.W | 0.21 | 0.31 | 29.19 | 10.81 | 0.000 | ||
| TZ_1-A3.B1 | 0.37 | 0.54 | 51.89 | 19.22 | 0.000 | ||
| TZ_1-A3.B2 | 0.35 | 0.52 | 49.43 | 18.31 | 0.000 | ||
| TZ_1-A3.LK | 1.67 | 2.44 | 232.71 | 86.19 | 0.000 | ||
| TZ_1-A3.W1 | 0.21 | 0.31 | 29.19 | 10.81 | 0.000 | ||
| TZ_1-A3.W2 | 0.21 | 0.31 | 29.19 | 10.81 | 0.000 | ||
| Total Facility | 5.63 | 8.23 | 784.84 | 290.68 | 0.0000 | 0.000 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| TZ_0-A1.B | 0.00 | 204463.23 | 204463.23 | 826857.22 | 1031320.44 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| TZ_0-A1.LK | 0.00 | 396744.30 | 396744.30 | 556159.91 | 952904.22 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| TZ_0-A1.W | 0.00 | 115038.83 | 115038.83 | 270697.30 | 385736.13 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| TZ_0-A2.B | 0.00 | 194781.34 | 194781.34 | 807170.14 | 1001951.49 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| TZ_0-A2.LK | 0.00 | 520268.07 | 520268.07 | 1279659.98 | 1799928.05 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| TZ_0-A2.W | 0.00 | 115038.83 | 115038.83 | 270697.30 | 385736.13 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| TZ_1-A3.B1 | 0.00 | 204475.90 | 204475.90 | 826908.26 | 1031384.16 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| TZ_1-A3.B2 | 0.00 | 194793.42 | 194793.42 | 807219.96 | 1002013.39 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| TZ_1-A3.LK | 0.00 | 917069.23 | 917069.23 | 1835933.21 | 2753002.44 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| TZ_1-A3.W1 | 0.00 | 115045.96 | 115045.96 | 270714.01 | 385759.97 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| TZ_1-A3.W2 | 0.00 | 115045.96 | 115045.96 | 270714.01 | 385759.97 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| Total Facility | 0.00 | 3092765.07 | 3092765.07 | 8022731.32 | 11115496.39 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| TZ_0-A1.B | 0.0000 | 0.0065 | 0.0065 | 0.0262 | 0.0327 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| TZ_0-A1.LK | 0.0000 | 0.0126 | 0.0126 | 0.0176 | 0.0302 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| TZ_0-A1.W | 0.0000 | 0.0036 | 0.0036 | 0.0086 | 0.0122 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| TZ_0-A2.B | 0.0000 | 0.0062 | 0.0062 | 0.0256 | 0.0318 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| TZ_0-A2.LK | 0.0000 | 0.0165 | 0.0165 | 0.0406 | 0.0571 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| TZ_0-A2.W | 0.0000 | 0.0036 | 0.0036 | 0.0086 | 0.0122 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| TZ_1-A3.B1 | 0.0000 | 0.0065 | 0.0065 | 0.0262 | 0.0327 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| TZ_1-A3.B2 | 0.0000 | 0.0062 | 0.0062 | 0.0256 | 0.0318 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| TZ_1-A3.LK | 0.0000 | 0.0291 | 0.0291 | 0.0582 | 0.0873 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| TZ_1-A3.W1 | 0.0000 | 0.0036 | 0.0036 | 0.0086 | 0.0122 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| TZ_1-A3.W2 | 0.0000 | 0.0036 | 0.0036 | 0.0086 | 0.0122 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| Total Facility | 0.0000 | 0.0981 | 0.0981 | 0.2544 | 0.3525 | 0.0000 | 0.00 | 0.00 | 8760.00 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| None |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| None |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| None |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| None |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Surfaces by Class| Total | Outdoors | |
| Wall | 88 | 22 |
| Floor | 14 | 7 |
| Roof | 13 | 6 |
| Internal Mass | 0 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 16 | 16 |
| Door | 22 | 0 |
| Glass Door | 1 | 1 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 0 |
| Conditioned Zones | 11 |
| Unconditioned Zones | 2 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 435 |
| Defaulted Fields | 659 |
| Fields with Defaults | 1355 |
| Autosized Fields | 0 |
| Autosizable Fields | 44 |
| Autocalculated Fields | 385 |
| Autocalculatable Fields | 385 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 58.90 | 1138.55 | 01-JAN-03:10 | 3034.14 | 01-JAN-19:10 |
| Electricity:Building | 58.90 | 1138.55 | 01-JAN-03:10 | 3034.14 | 01-JAN-19:10 |
| Electricity:Zone:TZ_1-A3.B1 | 2.92 | 44.29 | 01-JAN-03:10 | 169.61 | 01-JAN-19:10 |
| Electricity:SpaceType:MIDRISEAPARTMENT APARTMENT | 44.12 | 669.95 | 01-JAN-03:10 | 2565.53 | 01-JAN-19:10 |
| InteriorLights:Electricity | 26.44 | 544.07 | 01-JAN-00:10 | 1594.99 | 01-JAN-20:10 |
| InteriorLights:Electricity:Zone:TZ_1-A3.B1 | 0.77 | 4.99 | 01-JAN-00:10 | 74.47 | 01-JAN-20:10 |
| InteriorLights:Electricity:SpaceType:MIDRISEAPARTMENT APARTMENT | 11.66 | 75.47 | 01-JAN-00:10 | 1126.39 | 01-JAN-20:10 |
| General:InteriorLights:Electricity | 26.44 | 544.07 | 01-JAN-00:10 | 1594.99 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:Zone:TZ_1-A3.B1 | 0.77 | 4.99 | 01-JAN-00:10 | 74.47 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:SpaceType:MIDRISEAPARTMENT APARTMENT | 11.66 | 75.47 | 01-JAN-00:10 | 1126.39 | 01-JAN-20:10 |
| Electricity:Zone:TZ_0-A2.B | 2.78 | 42.19 | 01-JAN-03:10 | 161.58 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:TZ_0-A2.B | 0.73 | 4.75 | 01-JAN-00:10 | 70.94 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:Zone:TZ_0-A2.B | 0.73 | 4.75 | 01-JAN-00:10 | 70.94 | 01-JAN-20:10 |
| Electricity:Zone:TZ_0-A1.LK | 5.66 | 85.94 | 01-JAN-03:10 | 329.12 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:TZ_0-A1.LK | 1.50 | 9.68 | 01-JAN-00:10 | 144.50 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:Zone:TZ_0-A1.LK | 1.50 | 9.68 | 01-JAN-00:10 | 144.50 | 01-JAN-20:10 |
| Electricity:Zone:TZ_0-A2.LK | 7.42 | 112.70 | 01-JAN-03:10 | 431.59 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:TZ_0-A2.LK | 1.96 | 12.70 | 01-JAN-00:10 | 189.49 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:Zone:TZ_0-A2.LK | 1.96 | 12.70 | 01-JAN-00:10 | 189.49 | 01-JAN-20:10 |
| Electricity:Zone:TZ_1-A3.W1 | 1.64 | 24.92 | 01-JAN-03:10 | 95.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:TZ_1-A3.W1 | 0.43 | 2.81 | 01-JAN-00:10 | 41.90 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:Zone:TZ_1-A3.W1 | 0.43 | 2.81 | 01-JAN-00:10 | 41.90 | 01-JAN-20:10 |
| Electricity:Zone:TZ_0-A1.B | 2.92 | 44.29 | 01-JAN-03:10 | 169.61 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:TZ_0-A1.B | 0.77 | 4.99 | 01-JAN-00:10 | 74.47 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:Zone:TZ_0-A1.B | 0.77 | 4.99 | 01-JAN-00:10 | 74.47 | 01-JAN-20:10 |
| Electricity:Zone:TZ_0-A1.W | 1.64 | 24.92 | 01-JAN-03:10 | 95.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:TZ_0-A1.W | 0.43 | 2.81 | 01-JAN-00:10 | 41.90 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:Zone:TZ_0-A1.W | 0.43 | 2.81 | 01-JAN-00:10 | 41.90 | 01-JAN-20:10 |
| Electricity:Zone:TZ_0-A2.W | 1.64 | 24.92 | 01-JAN-03:10 | 95.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:TZ_0-A2.W | 0.43 | 2.81 | 01-JAN-00:10 | 41.90 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:Zone:TZ_0-A2.W | 0.43 | 2.81 | 01-JAN-00:10 | 41.90 | 01-JAN-20:10 |
| Electricity:Zone:TZ_1-A3.B2 | 2.78 | 42.19 | 01-JAN-03:10 | 161.58 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:TZ_1-A3.B2 | 0.73 | 4.75 | 01-JAN-00:10 | 70.94 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:Zone:TZ_1-A3.B2 | 0.73 | 4.75 | 01-JAN-00:10 | 70.94 | 01-JAN-20:10 |
| Electricity:Zone:TZ_1-A3.LK | 13.08 | 198.65 | 01-JAN-03:10 | 760.71 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:TZ_1-A3.LK | 3.46 | 22.38 | 01-JAN-00:10 | 333.99 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:Zone:TZ_1-A3.LK | 3.46 | 22.38 | 01-JAN-00:10 | 333.99 | 01-JAN-20:10 |
| Electricity:Zone:TZ_1-A3.W2 | 1.64 | 24.92 | 01-JAN-03:10 | 95.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:TZ_1-A3.W2 | 0.43 | 2.81 | 01-JAN-00:10 | 41.90 | 01-JAN-20:10 |
| General:InteriorLights:Electricity:Zone:TZ_1-A3.W2 | 0.43 | 2.81 | 01-JAN-00:10 | 41.90 | 01-JAN-20:10 |
| Electricity:Zone:TZ_0-H | 7.39 | 234.30 | 01-JAN-00:10 | 234.30 | 01-JAN-00:10 |
| Electricity:SpaceType:MIDRISEAPARTMENT CORRIDOR | 14.78 | 468.60 | 01-JAN-00:10 | 468.60 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:TZ_0-H | 7.39 | 234.30 | 01-JAN-00:10 | 234.30 | 01-JAN-00:10 |
| InteriorLights:Electricity:SpaceType:MIDRISEAPARTMENT CORRIDOR | 14.78 | 468.60 | 01-JAN-00:10 | 468.60 | 01-JAN-00:10 |
| General:InteriorLights:Electricity:Zone:TZ_0-H | 7.39 | 234.30 | 01-JAN-00:10 | 234.30 | 01-JAN-00:10 |
| General:InteriorLights:Electricity:SpaceType:MIDRISEAPARTMENT CORRIDOR | 14.78 | 468.60 | 01-JAN-00:10 | 468.60 | 01-JAN-00:10 |
| Electricity:Zone:TZ_1-H | 7.39 | 234.30 | 01-JAN-00:10 | 234.30 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:TZ_1-H | 7.39 | 234.30 | 01-JAN-00:10 | 234.30 | 01-JAN-00:10 |
| General:InteriorLights:Electricity:Zone:TZ_1-H | 7.39 | 234.30 | 01-JAN-00:10 | 234.30 | 01-JAN-00:10 |
| InteriorEquipment:Electricity | 32.46 | 594.48 | 01-JAN-03:10 | 1564.43 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:TZ_1-A3.B1 | 2.15 | 39.30 | 01-JAN-03:10 | 103.43 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:SpaceType:MIDRISEAPARTMENT APARTMENT | 32.46 | 594.48 | 01-JAN-03:10 | 1564.43 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity | 32.46 | 594.48 | 01-JAN-03:10 | 1564.43 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:Zone:TZ_1-A3.B1 | 2.15 | 39.30 | 01-JAN-03:10 | 103.43 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:SpaceType:MIDRISEAPARTMENT APARTMENT | 32.46 | 594.48 | 01-JAN-03:10 | 1564.43 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:TZ_0-A2.B | 2.04 | 37.44 | 01-JAN-03:10 | 98.53 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:Zone:TZ_0-A2.B | 2.04 | 37.44 | 01-JAN-03:10 | 98.53 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:TZ_0-A1.LK | 4.16 | 76.26 | 01-JAN-03:10 | 200.69 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:Zone:TZ_0-A1.LK | 4.16 | 76.26 | 01-JAN-03:10 | 200.69 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:TZ_0-A2.LK | 5.46 | 100.01 | 01-JAN-03:10 | 263.18 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:Zone:TZ_0-A2.LK | 5.46 | 100.01 | 01-JAN-03:10 | 263.18 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:TZ_1-A3.W1 | 1.21 | 22.11 | 01-JAN-03:10 | 58.19 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:Zone:TZ_1-A3.W1 | 1.21 | 22.11 | 01-JAN-03:10 | 58.19 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:TZ_0-A1.B | 2.15 | 39.30 | 01-JAN-03:10 | 103.43 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:Zone:TZ_0-A1.B | 2.15 | 39.30 | 01-JAN-03:10 | 103.43 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:TZ_0-A1.W | 1.21 | 22.11 | 01-JAN-03:10 | 58.19 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:Zone:TZ_0-A1.W | 1.21 | 22.11 | 01-JAN-03:10 | 58.19 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:TZ_0-A2.W | 1.21 | 22.11 | 01-JAN-03:10 | 58.19 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:Zone:TZ_0-A2.W | 1.21 | 22.11 | 01-JAN-03:10 | 58.19 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:TZ_1-A3.B2 | 2.04 | 37.44 | 01-JAN-03:10 | 98.53 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:Zone:TZ_1-A3.B2 | 2.04 | 37.44 | 01-JAN-03:10 | 98.53 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:TZ_1-A3.LK | 9.62 | 176.27 | 01-JAN-03:10 | 463.87 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:Zone:TZ_1-A3.LK | 9.62 | 176.27 | 01-JAN-03:10 | 463.87 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:TZ_1-A3.W2 | 1.21 | 22.11 | 01-JAN-03:10 | 58.19 | 01-JAN-17:10 |
| General:InteriorEquipment:Electricity:Zone:TZ_1-A3.W2 | 1.21 | 22.11 | 01-JAN-03:10 | 58.19 | 01-JAN-17:10 |
| Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:TZ_0-A1.B | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:TZ_0-A1.B | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:TZ_0-A1.LK | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:TZ_0-A1.LK | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:TZ_0-A1.W | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:TZ_0-A1.W | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:TZ_0-A2.B | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:TZ_0-A2.B | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:TZ_0-A2.LK | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:TZ_0-A2.LK | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:TZ_0-A2.W | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:TZ_0-A2.W | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:TZ_1-A3.B1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:TZ_1-A3.B1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:TZ_1-A3.B2 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:TZ_1-A3.B2 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:TZ_1-A3.LK | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:TZ_1-A3.LK | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:TZ_1-A3.W1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:TZ_1-A3.W1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:TZ_1-A3.W2 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:TZ_1-A3.W2 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 58.90 | 1138.55 | 01-JAN-03:10 | 3034.14 | 01-JAN-19:10 |
| ElectricityPurchased:Plant | 58.90 | 1138.55 | 01-JAN-03:10 | 3034.14 | 01-JAN-19:10 |
| Cogeneration:ElectricityPurchased | 58.90 | 1138.55 | 01-JAN-03:10 | 3034.14 | 01-JAN-19:10 |
| General:Cogeneration:ElectricityPurchased | 58.90 | 1138.55 | 01-JAN-03:10 | 3034.14 | 01-JAN-19:10 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 58.90 | 1138.55 | 01-JAN-03:10 | 3034.14 | 01-JAN-19:10 |
| ElectricityNet:Plant | 58.90 | 1138.55 | 01-JAN-03:10 | 3034.14 | 01-JAN-19:10 |
| Cogeneration:ElectricityNet | 58.90 | 1138.55 | 01-JAN-03:10 | 3034.14 | 01-JAN-19:10 |
| General:Cogeneration:ElectricityNet | 58.90 | 1138.55 | 01-JAN-03:10 | 3034.14 | 01-JAN-19:10 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| DistrictCooling:Facility | 9.80 | 0.00 | 01-JAN-00:10 | 9110.11 | 21-JUL-18:10 |
| DistrictCooling:HVAC | 9.80 | 0.00 | 01-JAN-00:10 | 9110.11 | 21-JUL-18:10 |
| Cooling:DistrictCooling | 9.80 | 0.00 | 01-JAN-00:10 | 9110.11 | 21-JUL-18:10 |
| General:Cooling:DistrictCooling | 9.80 | 0.00 | 01-JAN-00:10 | 9110.11 | 21-JUL-18:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 151.64 | 0.00 | 06-MAR-16:10 | 22048.54 | 30-JAN-04:00 |
| EnergyTransfer:Building | 151.64 | 0.00 | 06-MAR-16:10 | 22048.54 | 30-JAN-04:00 |
| EnergyTransfer:Zone:TZ_0-A1.B | 12.97 | 0.00 | 06-MAR-16:10 | 1782.02 | 30-JAN-04:00 |
| Heating:EnergyTransfer | 144.38 | 0.00 | 06-MAR-16:10 | 22048.54 | 30-JAN-04:00 |
| Heating:EnergyTransfer:Zone:TZ_0-A1.B | 12.92 | 0.00 | 06-MAR-16:10 | 1782.02 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer | 144.38 | 0.00 | 06-MAR-16:10 | 22048.54 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer:Zone:TZ_0-A1.B | 12.92 | 0.00 | 06-MAR-16:10 | 1782.02 | 30-JAN-04:00 |
| Cooling:EnergyTransfer | 7.26 | 0.00 | 01-JAN-00:10 | 6557.56 | 24-JUL-18:10 |
| Cooling:EnergyTransfer:Zone:TZ_0-A1.B | 0.05 | 0.00 | 01-JAN-00:10 | 314.82 | 21-JUL-19:00 |
| General:Cooling:EnergyTransfer | 7.26 | 0.00 | 01-JAN-00:10 | 6557.56 | 24-JUL-18:10 |
| General:Cooling:EnergyTransfer:Zone:TZ_0-A1.B | 0.05 | 0.00 | 01-JAN-00:10 | 314.82 | 21-JUL-19:00 |
| EnergyTransfer:Zone:TZ_0-A1.LK | 12.95 | 0.00 | 06-MAR-15:10 | 2020.78 | 30-JAN-04:00 |
| Heating:EnergyTransfer:Zone:TZ_0-A1.LK | 12.89 | 0.00 | 06-MAR-15:10 | 2020.78 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer:Zone:TZ_0-A1.LK | 12.89 | 0.00 | 06-MAR-15:10 | 2020.78 | 30-JAN-04:00 |
| Cooling:EnergyTransfer:Zone:TZ_0-A1.LK | 0.05 | 0.00 | 01-JAN-00:10 | 380.54 | 24-JUL-18:10 |
| General:Cooling:EnergyTransfer:Zone:TZ_0-A1.LK | 0.05 | 0.00 | 01-JAN-00:10 | 380.54 | 24-JUL-18:10 |
| EnergyTransfer:Zone:TZ_0-A1.W | 4.77 | 0.00 | 06-MAR-14:50 | 713.45 | 30-JAN-04:00 |
| Heating:EnergyTransfer:Zone:TZ_0-A1.W | 4.75 | 0.00 | 06-MAR-14:50 | 713.45 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer:Zone:TZ_0-A1.W | 4.75 | 0.00 | 06-MAR-14:50 | 713.45 | 30-JAN-04:00 |
| Cooling:EnergyTransfer:Zone:TZ_0-A1.W | 0.02 | 0.00 | 01-JAN-00:10 | 116.24 | 21-JUL-19:00 |
| General:Cooling:EnergyTransfer:Zone:TZ_0-A1.W | 0.02 | 0.00 | 01-JAN-00:10 | 116.24 | 21-JUL-19:00 |
| EnergyTransfer:Zone:TZ_0-A2.B | 12.00 | 0.00 | 17-FEB-13:20 | 1711.55 | 30-JAN-04:00 |
| Heating:EnergyTransfer:Zone:TZ_0-A2.B | 11.86 | 0.00 | 17-FEB-13:20 | 1711.55 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer:Zone:TZ_0-A2.B | 11.86 | 0.00 | 17-FEB-13:20 | 1711.55 | 30-JAN-04:00 |
| Cooling:EnergyTransfer:Zone:TZ_0-A2.B | 0.14 | 0.00 | 01-JAN-00:10 | 337.07 | 21-JUL-19:00 |
| General:Cooling:EnergyTransfer:Zone:TZ_0-A2.B | 0.14 | 0.00 | 01-JAN-00:10 | 337.07 | 21-JUL-19:00 |
| EnergyTransfer:Zone:TZ_0-A2.LK | 22.39 | 0.00 | 17-FEB-14:30 | 3362.02 | 30-JAN-04:00 |
| Heating:EnergyTransfer:Zone:TZ_0-A2.LK | 22.11 | 0.00 | 17-FEB-14:30 | 3362.02 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer:Zone:TZ_0-A2.LK | 22.11 | 0.00 | 17-FEB-14:30 | 3362.02 | 30-JAN-04:00 |
| Cooling:EnergyTransfer:Zone:TZ_0-A2.LK | 0.27 | 0.00 | 01-JAN-00:10 | 812.50 | 24-JUL-18:10 |
| General:Cooling:EnergyTransfer:Zone:TZ_0-A2.LK | 0.27 | 0.00 | 01-JAN-00:10 | 812.50 | 24-JUL-18:10 |
| EnergyTransfer:Zone:TZ_0-A2.W | 4.68 | 0.00 | 17-FEB-16:10 | 710.71 | 30-JAN-04:00 |
| Heating:EnergyTransfer:Zone:TZ_0-A2.W | 4.66 | 0.00 | 17-FEB-16:10 | 710.71 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer:Zone:TZ_0-A2.W | 4.66 | 0.00 | 17-FEB-16:10 | 710.71 | 30-JAN-04:00 |
| Cooling:EnergyTransfer:Zone:TZ_0-A2.W | 0.02 | 0.00 | 01-JAN-00:10 | 123.99 | 21-JUL-19:00 |
| General:Cooling:EnergyTransfer:Zone:TZ_0-A2.W | 0.02 | 0.00 | 01-JAN-00:10 | 123.99 | 21-JUL-19:00 |
| EnergyTransfer:Zone:TZ_0-H | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:TZ_0-H | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:TZ_0-H | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:TZ_0-H | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:TZ_0-H | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:TZ_1-A3.B1 | 14.40 | 0.00 | 01-MAR-14:20 | 1970.97 | 30-JAN-04:00 |
| Heating:EnergyTransfer:Zone:TZ_1-A3.B1 | 13.65 | 0.00 | 01-MAR-14:20 | 1970.97 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer:Zone:TZ_1-A3.B1 | 13.65 | 0.00 | 01-MAR-14:20 | 1970.97 | 30-JAN-04:00 |
| Cooling:EnergyTransfer:Zone:TZ_1-A3.B1 | 0.75 | 0.00 | 01-JAN-00:10 | 627.54 | 25-JUL-13:00 |
| General:Cooling:EnergyTransfer:Zone:TZ_1-A3.B1 | 0.75 | 0.00 | 01-JAN-00:10 | 627.54 | 25-JUL-13:00 |
| EnergyTransfer:Zone:TZ_1-A3.B2 | 13.82 | 0.00 | 09-FEB-12:40 | 1903.58 | 30-JAN-04:00 |
| Heating:EnergyTransfer:Zone:TZ_1-A3.B2 | 12.67 | 0.00 | 09-FEB-12:40 | 1903.58 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer:Zone:TZ_1-A3.B2 | 12.67 | 0.00 | 09-FEB-12:40 | 1903.58 | 30-JAN-04:00 |
| Cooling:EnergyTransfer:Zone:TZ_1-A3.B2 | 1.14 | 0.00 | 01-JAN-00:10 | 852.18 | 23-JUL-13:40 |
| General:Cooling:EnergyTransfer:Zone:TZ_1-A3.B2 | 1.14 | 0.00 | 01-JAN-00:10 | 852.18 | 23-JUL-13:40 |
| EnergyTransfer:Zone:TZ_1-A3.LK | 42.39 | 0.00 | 17-FEB-13:20 | 6239.18 | 30-JAN-04:00 |
| Heating:EnergyTransfer:Zone:TZ_1-A3.LK | 38.60 | 0.00 | 17-FEB-13:20 | 6239.18 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer:Zone:TZ_1-A3.LK | 38.60 | 0.00 | 17-FEB-13:20 | 6239.18 | 30-JAN-04:00 |
| Cooling:EnergyTransfer:Zone:TZ_1-A3.LK | 3.79 | 0.00 | 01-JAN-00:10 | 2751.98 | 23-JUL-16:10 |
| General:Cooling:EnergyTransfer:Zone:TZ_1-A3.LK | 3.79 | 0.00 | 01-JAN-00:10 | 2751.98 | 23-JUL-16:10 |
| EnergyTransfer:Zone:TZ_1-A3.W1 | 5.65 | 0.00 | 17-FEB-14:50 | 817.89 | 30-JAN-04:00 |
| Heating:EnergyTransfer:Zone:TZ_1-A3.W1 | 5.17 | 0.00 | 17-FEB-14:50 | 817.89 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer:Zone:TZ_1-A3.W1 | 5.17 | 0.00 | 17-FEB-14:50 | 817.89 | 30-JAN-04:00 |
| Cooling:EnergyTransfer:Zone:TZ_1-A3.W1 | 0.48 | 0.00 | 01-JAN-00:10 | 343.51 | 25-JUL-11:40 |
| General:Cooling:EnergyTransfer:Zone:TZ_1-A3.W1 | 0.48 | 0.00 | 01-JAN-00:10 | 343.51 | 25-JUL-11:40 |
| EnergyTransfer:Zone:TZ_1-A3.W2 | 5.63 | 0.00 | 17-FEB-13:00 | 816.40 | 30-JAN-04:00 |
| Heating:EnergyTransfer:Zone:TZ_1-A3.W2 | 5.10 | 0.00 | 17-FEB-13:00 | 816.40 | 30-JAN-04:00 |
| General:Heating:EnergyTransfer:Zone:TZ_1-A3.W2 | 5.10 | 0.00 | 17-FEB-13:00 | 816.40 | 30-JAN-04:00 |
| Cooling:EnergyTransfer:Zone:TZ_1-A3.W2 | 0.53 | 0.00 | 01-JAN-00:10 | 359.87 | 25-JUL-13:00 |
| General:Cooling:EnergyTransfer:Zone:TZ_1-A3.W2 | 0.53 | 0.00 | 01-JAN-00:10 | 359.87 | 25-JUL-13:00 |
| EnergyTransfer:Zone:TZ_1-H | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:TZ_1-H | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:TZ_1-H | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:TZ_1-H | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:TZ_1-H | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| DistrictHeatingWater:Facility | 144.38 | 0.00 | 06-MAR-16:10 | 22048.54 | 30-JAN-04:00 |
| DistrictHeatingWater:HVAC | 144.38 | 0.00 | 06-MAR-16:10 | 22048.54 | 30-JAN-04:00 |
| Heating:DistrictHeatingWater | 144.38 | 0.00 | 06-MAR-16:10 | 22048.54 | 30-JAN-04:00 |
| General:Heating:DistrictHeatingWater | 144.38 | 0.00 | 06-MAR-16:10 | 22048.54 | 30-JAN-04:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| TZ_0-A1.B | 12.918 | -0.054 | 0.000 | 0.000 | 0.000 | 0.000 | 0.977 | 0.771 | 2.146 | 0.674 | 0.000 | 0.183 | 0.000 | 0.000 | -1.443 | 0.000 | -12.004 | -4.169 |
| TZ_0-A1.LK | 12.893 | -0.054 | 0.000 | 0.000 | 0.000 | 0.000 | 1.882 | 1.496 | 4.164 | 1.024 | 0.000 | 0.171 | 0.000 | 0.000 | -2.168 | 0.000 | -11.510 | -7.899 |
| TZ_0-A1.W | 4.751 | -0.016 | 0.000 | 0.000 | 0.000 | 0.000 | 0.547 | 0.434 | 1.207 | 0.753 | 0.000 | 0.064 | 0.000 | 0.000 | -0.709 | 0.000 | -4.587 | -2.444 |
| TZ_0-A2.B | 11.861 | -0.137 | 0.000 | 0.000 | 0.000 | 0.000 | 0.926 | 0.735 | 2.044 | 2.146 | 0.000 | 0.121 | 0.000 | 0.000 | -1.398 | 0.000 | -11.776 | -4.523 |
| TZ_0-A2.LK | 22.113 | -0.273 | 0.000 | 0.000 | 0.000 | 0.000 | 2.466 | 1.962 | 5.460 | 4.756 | 0.000 | 0.240 | 0.000 | 0.000 | -3.468 | 0.000 | -21.458 | -11.798 |
| TZ_0-A2.W | 4.662 | -0.022 | 0.000 | 0.000 | 0.000 | 0.000 | 0.546 | 0.434 | 1.207 | 0.748 | 0.000 | 0.058 | 0.000 | 0.000 | -0.712 | 0.000 | -4.602 | -2.319 |
| TZ_1-A3.B1 | 13.650 | -0.752 | 0.000 | 0.000 | 0.000 | 0.000 | 0.961 | 0.771 | 2.146 | 0.570 | 0.000 | 0.100 | 0.000 | 0.000 | -1.464 | 0.000 | -12.426 | -3.555 |
| TZ_1-A3.B2 | 12.673 | -1.145 | 0.000 | 0.000 | 0.000 | 0.000 | 0.911 | 0.735 | 2.044 | 2.032 | 0.000 | 0.097 | 0.000 | 0.000 | -1.413 | 0.000 | -12.211 | -3.723 |
| TZ_1-A3.LK | 38.596 | -3.795 | 0.000 | 0.000 | 0.000 | 0.000 | 4.269 | 3.458 | 9.624 | 5.232 | 0.000 | 0.248 | 0.000 | 0.000 | -5.584 | 0.000 | -34.197 | -17.852 |
| TZ_1-A3.W1 | 5.167 | -0.484 | 0.000 | 0.000 | 0.000 | 0.000 | 0.535 | 0.434 | 1.207 | 0.701 | 0.000 | 0.035 | 0.000 | 0.000 | -0.725 | 0.000 | -4.778 | -2.092 |
| TZ_1-A3.W2 | 5.098 | -0.532 | 0.000 | 0.000 | 0.000 | 0.000 | 0.534 | 0.434 | 1.207 | 0.697 | 0.000 | 0.035 | 0.000 | 0.000 | -0.728 | 0.000 | -4.795 | -1.951 |
| TZ_0-H | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 7.389 | 0.000 | 2.632 | 0.000 | 0.037 | 2.007 | 0.000 | -3.180 | 0.000 | -8.884 | 0.000 |
| TZ_1-H | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 7.389 | 0.000 | 1.439 | 0.000 | 0.000 | 1.550 | 0.000 | -1.080 | 0.000 | -9.298 | 0.000 |
| Total Facility | 144.381 | -7.263 | 0.000 | 0.000 | 0.000 | 0.000 | 14.554 | 26.441 | 32.459 | 23.402 | 0.000 | 1.389 | 3.557 | 0.000 | -24.071 | 0.000 | -152.526 | -62.323 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| TZ_0-A1.B | 21-JUL-18:00 | 0.00 | -314.86 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 61.73 | 103.43 | 59.30 | 0.00 | 245.10 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -182.97 |
| TZ_0-A1.LK | 24-JUL-18:10 | 0.00 | -380.51 | 0.00 | 0.00 | 0.00 | 0.00 | 54.84 | 119.79 | 200.69 | 141.43 | 0.00 | 210.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -346.24 |
| TZ_0-A1.W | 21-JUL-18:00 | 0.00 | -116.25 | 0.00 | 0.00 | 0.00 | 0.00 | 15.90 | 34.73 | 58.19 | 25.61 | 0.00 | 93.99 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -112.17 |
| TZ_0-A2.B | 21-JUL-18:00 | 0.00 | -337.11 | 0.00 | 0.00 | 0.00 | 0.00 | 26.92 | 58.81 | 98.53 | 50.55 | 0.00 | 237.89 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -135.59 |
| TZ_0-A2.LK | 24-JUL-18:10 | 0.00 | -812.54 | 0.00 | 0.00 | 0.00 | 0.00 | 71.91 | 157.09 | 263.18 | 439.57 | 0.00 | 384.58 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -503.78 |
| TZ_0-A2.W | 21-JUL-18:00 | 0.00 | -124.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.90 | 34.73 | 58.19 | 25.41 | 0.00 | 93.99 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -104.23 |
| TZ_1-A3.B1 | 25-JUL-12:00 | 0.00 | -627.39 | 0.00 | 0.00 | 0.00 | 0.00 | 8.12 | 8.86 | 71.37 | 129.26 | 0.00 | 140.31 | 269.47 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.B2 | 23-JUL-13:39 | 0.00 | -852.16 | 0.00 | 0.00 | 0.00 | 0.00 | 7.74 | 8.44 | 65.03 | 386.91 | 0.00 | 170.46 | 213.58 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.LK | 23-JUL-16:10 | 0.00 | -2752.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.71 | 146.62 | 371.10 | 962.00 | 0.00 | 477.61 | 750.96 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W1 | 25-JUL-11:39 | 0.00 | -343.48 | 0.00 | 0.00 | 0.00 | 0.00 | 4.57 | 4.99 | 40.73 | 105.47 | 0.00 | 36.95 | 150.77 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-A3.W2 | 25-JUL-12:00 | 0.00 | -359.85 | 0.00 | 0.00 | 0.00 | 0.00 | 4.57 | 4.99 | 40.15 | 65.03 | 0.00 | 48.66 | 196.46 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| TZ_0-H | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 24-JUL-18:10 | 0.00 | -6557.96 | 0.00 | 0.00 | 0.00 | 0.00 | 427.49 | 1402.38 | 1564.43 | 2401.75 | 0.00 | 2368.37 | 0.00 | 0.00 | 0.00 | 0.00 | -131.08 | -1475.36 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| TZ_0-A1.B | 30-JAN-03:00 | 1781.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.11 | 4.99 | 39.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -169.58 | 0.00 | -1441.12 | -262.70 |
| TZ_0-A1.LK | 30-JAN-03:00 | 2020.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.42 | 9.68 | 76.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -253.11 | 0.00 | -1452.71 | -492.29 |
| TZ_0-A1.W | 30-JAN-03:00 | 713.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.51 | 2.81 | 22.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -85.97 | 0.00 | -561.49 | -117.40 |
| TZ_0-A2.B | 30-JAN-03:00 | 1711.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.88 | 4.75 | 37.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -169.98 | 0.00 | -1397.83 | -230.80 |
| TZ_0-A2.LK | 30-JAN-03:00 | 3361.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.89 | 12.70 | 100.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -420.83 | 0.00 | -2610.41 | -563.31 |
| TZ_0-A2.W | 30-JAN-03:00 | 710.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.51 | 2.81 | 22.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -86.01 | 0.00 | -561.49 | -114.62 |
| TZ_1-A3.B1 | 30-JAN-03:00 | 1970.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.11 | 4.99 | 39.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -166.49 | 0.00 | -1442.03 | -453.82 |
| TZ_1-A3.B2 | 30-JAN-03:00 | 1903.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.88 | 4.75 | 37.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -166.72 | 0.00 | -1398.71 | -425.19 |
| TZ_1-A3.LK | 30-JAN-03:00 | 6239.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 211.31 | 22.38 | 176.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -653.82 | 0.00 | -4065.70 | -1929.51 |
| TZ_1-A3.W1 | 30-JAN-03:00 | 817.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.51 | 2.81 | 22.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -84.67 | 0.00 | -561.85 | -222.78 |
| TZ_1-A3.W2 | 30-JAN-03:00 | 816.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.51 | 2.81 | 22.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -84.70 | 0.00 | -561.85 | -221.27 |
| TZ_0-H | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TZ_1-H | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 30-JAN-03:00 | 22048.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 712.65 | 544.07 | 594.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2773.14 | 0.00 | -17651.29 | -3474.92 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Sec1.1A-General Information| Data | |
| Weather File | RUN PERIOD 1 ** MILAN - ITA IWEC Data WMO#=160660 |
| Total gross floor area [m2] | 338.00 |
| Principal Heating Source | District Heating Water |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| TZ_0-A1.B | 19.22 | 19.22 | 0.00 | 168.00 |
| TZ_0-A1.LK | 37.29 | 37.29 | 0.00 | 168.00 |
| TZ_0-A1.W | 10.81 | 10.81 | 0.00 | 168.00 |
| TZ_0-A2.B | 18.31 | 18.31 | 0.00 | 168.00 |
| TZ_0-A2.LK | 48.90 | 48.90 | 0.00 | 168.00 |
| TZ_0-A2.W | 10.81 | 10.81 | 0.00 | 168.00 |
| TZ_1-A3.B1 | 19.22 | 19.22 | 0.00 | 168.00 |
| TZ_1-A3.B2 | 18.31 | 18.31 | 0.00 | 168.00 |
| TZ_1-A3.LK | 86.19 | 86.19 | 0.00 | 168.00 |
| TZ_1-A3.W1 | 10.81 | 10.81 | 0.00 | 168.00 |
| TZ_1-A3.W2 | 10.81 | 10.81 | 0.00 | 168.00 |
| TZ_0-H | 23.66 | 0.00 | 23.66 | 0.00 |
| TZ_1-H | 23.66 | 0.00 | 23.66 | 0.00 |
| Totals | 338.00 | 290.68 | 47.32 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 0.00 |
| Number of hours not met | 0.00 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Water Use [GJ] | District Heating Water Demand [W] | District Heating Steam Use [GJ] | District Heating Steam Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.38 | 22048.54 | 0.00 | 0.00 |
| Cooling -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.80 | 9110.11 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- General | 26.44 | 1594.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- General | 32.46 | 1564.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 32.46 | 58.90 |
| Natural Gas | 0.00 | 0.00 |
| Additional | 0.00 | 154.18 |
| Total | 32.46 | 213.08 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 78.23 |
| Space Heating | 0.00 |
| Space Cooling | 0.00 |
| Fans (All) | 0.00 |
| Service Water Heating | 0.00 |
| Receptacle Equipment | 96.03 |
| Miscellaneous (All) | 174.26 |
| Subtotal | 174.26 |
| Natural Gas [MJ/m2] | |
| Space Heating | 0.00 |
| Service Water Heating | 0.00 |
| Miscellaneous (All) | 0.00 |
| Subtotal | 0.00 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 12.41 |
| Space Heating | 67.76 |
| Space Cooling | 4.60 |
| Fans (All) | 0.00 |
| Service Water Heating | 0.00 |
| Receptacle Equipment | 15.23 |
| Miscellaneous | -0.00 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| None |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HEATING SETPOINT | THERMOSTAT SETPOINT DUAL SETPOINT 1 | January | 20.00 | 365 | 20.00 | 365 |
| COOLING SETPOINT | THERMOSTAT SETPOINT DUAL SETPOINT 1 | July | 26.00 | 365 | 26.00 | 365 |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: BUILDING ENERGY PERFORMANCE - ELECTRICITY
For: Meter
Timestamp: 2024-09-12 18:15:00
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [] | COOLING:ELECTRICITY [] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | REFRIGERATION:ELECTRICITY [] | |
| January | 0.224565E+10 | 0.00 | 0.275678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.202833E+10 | 0.00 | 0.248999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.224565E+10 | 0.00 | 0.275678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.217321E+10 | 0.00 | 0.266785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.224565E+10 | 0.00 | 0.275678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.217321E+10 | 0.00 | 0.266785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.224565E+10 | 0.00 | 0.275678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.224565E+10 | 0.00 | 0.275678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.217321E+10 | 0.00 | 0.266785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.224565E+10 | 0.00 | 0.275678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.217321E+10 | 0.00 | 0.266785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.224565E+10 | 0.00 | 0.275678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.264408E+11 | 0.00 | 0.324588E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.202833E+10 | 0.00 | 0.248999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.224565E+10 | 0.00 | 0.275678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: BUILDING ENERGY PERFORMANCE - DISTRICT HEATING WATER
For: Meter
Timestamp: 2024-09-12 18:15:00
Custom Monthly Report| INTERIORLIGHTS:DISTRICTHEATINGWATER [] | EXTERIORLIGHTS:DISTRICTHEATINGWATER [] | INTERIOREQUIPMENT:DISTRICTHEATINGWATER [] | EXTERIOREQUIPMENT:DISTRICTHEATINGWATER [] | FANS:DISTRICTHEATINGWATER [] | PUMPS:DISTRICTHEATINGWATER [] | HEATING:DISTRICTHEATINGWATER [J] | COOLING:DISTRICTHEATINGWATER [] | HEATREJECTION:DISTRICTHEATINGWATER [] | HUMIDIFIER:DISTRICTHEATINGWATER [] | HEATRECOVERY:DISTRICTHEATINGWATER [] | WATERSYSTEMS:DISTRICTHEATINGWATER [] | COGENERATION:DISTRICTHEATINGWATER [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.312373E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.241887E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163467E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103462E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338604E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.967773E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26575377.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99210210.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.859973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189450E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144382E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26575377.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.312373E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: BUILDING ENERGY PERFORMANCE - DISTRICT COOLING
For: Meter
Timestamp: 2024-09-12 18:15:00
Custom Monthly Report| INTERIORLIGHTS:DISTRICTCOOLING [] | EXTERIORLIGHTS:DISTRICTCOOLING [] | INTERIOREQUIPMENT:DISTRICTCOOLING [] | EXTERIOREQUIPMENT:DISTRICTCOOLING [] | FANS:DISTRICTCOOLING [] | PUMPS:DISTRICTCOOLING [] | HEATING:DISTRICTCOOLING [] | COOLING:DISTRICTCOOLING [J] | HEATREJECTION:DISTRICTCOOLING [] | HUMIDIFIER:DISTRICTCOOLING [] | HEATRECOVERY:DISTRICTCOOLING [] | WATERSYSTEMS:DISTRICTCOOLING [] | COGENERATION:DISTRICTCOOLING [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 205507.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3355020.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.422799E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.417260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.262467E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.591483E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3596182.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.979831E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.417260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: BUILDING ENERGY PERFORMANCE - ELECTRICITY PEAK DEMAND
For: Meter
Timestamp: 2024-09-12 18:15:00
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY [] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [] | COOLING:ELECTRICITY [] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | REFRIGERATION:ELECTRICITY [] | |
| January | 3034.14 | 01-JAN-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 3034.14 | 01-FEB-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 3034.14 | 01-MAR-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 3034.14 | 01-APR-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 3034.14 | 01-MAY-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 3034.14 | 01-JUN-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 3034.14 | 01-JUL-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 3034.14 | 01-AUG-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 3034.14 | 01-SEP-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 3034.14 | 01-OCT-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 3034.14 | 01-NOV-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 3034.14 | 01-DEC-19:20 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
| Minimum of Months | 3034.14 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3034.14 | 1579.22 | 0.00 | 1454.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: BUILDING ENERGY PERFORMANCE - DISTRICT HEATING WATER PEAK DEMAND
For: Meter
Timestamp: 2024-09-12 18:15:00
Custom Monthly Report| DISTRICTHEATINGWATER:FACILITY {Maximum} [W] | DISTRICTHEATINGWATER:FACILITY {TIMESTAMP} | INTERIORLIGHTS:DISTRICTHEATINGWATER [] | EXTERIORLIGHTS:DISTRICTHEATINGWATER [] | INTERIOREQUIPMENT:DISTRICTHEATINGWATER [] | EXTERIOREQUIPMENT:DISTRICTHEATINGWATER [] | FANS:DISTRICTHEATINGWATER [] | PUMPS:DISTRICTHEATINGWATER [] | HEATING:DISTRICTHEATINGWATER {AT MAX/MIN} [W] | COOLING:DISTRICTHEATINGWATER [] | HEATREJECTION:DISTRICTHEATINGWATER [] | HUMIDIFIER:DISTRICTHEATINGWATER [] | HEATRECOVERY:DISTRICTHEATINGWATER [] | WATERSYSTEMS:DISTRICTHEATINGWATER [] | COGENERATION:DISTRICTHEATINGWATER [] | |
| January | 22048.54 | 30-JAN-03:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22048.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 18117.73 | 24-FEB-03:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18117.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 15679.92 | 01-MAR-05:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15679.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 14052.55 | 01-APR-05:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14052.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 8054.21 | 22-MAY-03:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8054.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 7747.35 | 13-JUN-03:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7747.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 1016.89 | 15-JUL-03:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1016.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 2386.39 | 13-AUG-04:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2386.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 7375.96 | 29-SEP-03:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7375.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 12158.94 | 31-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12158.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 15499.71 | 19-NOV-05:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15499.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 19707.85 | 29-DEC-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19707.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
| Minimum of Months | 1016.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1016.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 22048.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22048.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: BUILDING ENERGY PERFORMANCE - DISTRICT COOLING PEAK DEMAND
For: Meter
Timestamp: 2024-09-12 18:15:00
Custom Monthly Report| DISTRICTCOOLING:FACILITY {Maximum} [W] | DISTRICTCOOLING:FACILITY {TIMESTAMP} | INTERIORLIGHTS:DISTRICTCOOLING [] | EXTERIORLIGHTS:DISTRICTCOOLING [] | INTERIOREQUIPMENT:DISTRICTCOOLING [] | EXTERIOREQUIPMENT:DISTRICTCOOLING [] | FANS:DISTRICTCOOLING [] | PUMPS:DISTRICTCOOLING [] | HEATING:DISTRICTCOOLING [] | COOLING:DISTRICTCOOLING {AT MAX/MIN} [W] | HEATREJECTION:DISTRICTCOOLING [] | HUMIDIFIER:DISTRICTCOOLING [] | HEATRECOVERY:DISTRICTCOOLING [] | WATERSYSTEMS:DISTRICTCOOLING [] | COGENERATION:DISTRICTCOOLING [] | |
| January | 0.00 | 01-JAN-00:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 01-FEB-00:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 36.13 | 15-MAR-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 331.89 | 23-APR-16:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 331.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 2891.62 | 25-MAY-16:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2891.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 7881.15 | 26-JUN-17:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7881.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 9110.11 | 21-JUL-18:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9110.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 6747.23 | 06-AUG-16:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6747.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 4092.94 | 01-SEP-16:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4092.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 143.91 | 12-OCT-14:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 143.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 01-NOV-00:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 01-DEC-00:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 9110.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9110.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Life-Cycle Cost Report
For: Entire Facility
Timestamp: 2024-09-12 18:15:00
Life-Cycle Cost Parameters| Value | |
| Name | LIFE CYCLE COST PARAMETERS |
| Discounting Convention | EndOfYear |
| Inflation Approach | ConstantDollar |
| Real Discount Rate | 0.0300 |
| Nominal Discount Rate | -- N/A -- |
| Inflation | -- N/A -- |
| Base Date | January 2011 |
| Service Date | January 2011 |
| Length of Study Period in Years | 25 |
| Tax rate | 0.0000 |
| Depreciation Method | None |
| U.S. AVG COMMERCIAL-ELECTRICITY | U.S. AVG COMMERCIAL-DISTILLATE OIL | U.S. AVG COMMERCIAL-RESIDUAL OIL | U.S. AVG COMMERCIAL-NATURAL GAS | U.S. AVG COMMERCIAL-COAL | |
| Resource | Electricity | FuelOilNo1 | FuelOilNo2 | NaturalGas | Coal |
| Start Date | January 2011 | January 2011 | January 2011 | January 2011 | January 2011 |
| 1 | 0.983800 | 0.971400 | 0.846900 | 0.982300 | 0.997000 |
| 2 | 0.973000 | 0.973000 | 0.825700 | 0.955700 | 1.008900 |
| 3 | 0.963200 | 0.994200 | 0.868100 | 0.927900 | 1.008900 |
| 4 | 0.961100 | 1.016400 | 0.898800 | 0.925700 | 0.994100 |
| 5 | 0.957100 | 1.054100 | 0.928900 | 0.934600 | 0.994100 |
| 6 | 0.955300 | 1.092800 | 0.960400 | 0.941200 | 1.000000 |
| 7 | 0.953900 | 1.126700 | 0.989700 | 0.951200 | 1.003000 |
| 8 | 0.952100 | 1.158000 | 1.007500 | 0.964500 | 1.005900 |
| 9 | 0.954600 | 1.179200 | 1.031400 | 0.985600 | 1.008900 |
| 10 | 0.955000 | 1.196700 | 1.055400 | 1.006700 | 1.011900 |
| 11 | 0.955300 | 1.220000 | 1.086100 | 1.022200 | 1.014800 |
| 12 | 0.956400 | 1.233300 | 1.127800 | 1.041000 | 1.017800 |
| 13 | 0.957500 | 1.256600 | 1.149700 | 1.061000 | 1.020800 |
| 14 | 0.959600 | 1.270900 | 1.162000 | 1.078700 | 1.026700 |
| 15 | 0.961800 | 1.282600 | 1.174300 | 1.094200 | 1.029700 |
| 16 | 0.961400 | 1.298500 | 1.185200 | 1.109800 | 1.035600 |
| 17 | 0.961800 | 1.310200 | 1.194800 | 1.122000 | 1.041500 |
| 18 | 0.961800 | 1.325000 | 1.203700 | 1.130800 | 1.053400 |
| 19 | 0.959300 | 1.326100 | 1.207100 | 1.138600 | 1.056400 |
| 20 | 0.958900 | 1.328200 | 1.211900 | 1.148600 | 1.059300 |
| 21 | 0.960700 | 1.332400 | 1.213900 | 1.161900 | 1.065300 |
| 22 | 0.962500 | 1.335600 | 1.219400 | 1.176300 | 1.071200 |
| 23 | 0.965000 | 1.343100 | 1.227600 | 1.191800 | 1.074200 |
| 24 | 0.970800 | 1.351000 | 1.236500 | 1.211800 | 1.080100 |
| 25 | 0.975100 | 1.356800 | 1.242000 | 1.228400 | 1.083100 |
| DEFAULT COST | |
| Nonrecurring | |
| January 2011 | 0.00 |
| January 2012 | 0.00 |
| January 2013 | 0.00 |
| January 2014 | 0.00 |
| January 2015 | 0.00 |
| January 2016 | 0.00 |
| January 2017 | 0.00 |
| January 2018 | 0.00 |
| January 2019 | 0.00 |
| January 2020 | 0.00 |
| January 2021 | 0.00 |
| January 2022 | 0.00 |
| January 2023 | 0.00 |
| January 2024 | 0.00 |
| January 2025 | 0.00 |
| January 2026 | 0.00 |
| January 2027 | 0.00 |
| January 2028 | 0.00 |
| January 2029 | 0.00 |
| January 2030 | 0.00 |
| January 2031 | 0.00 |
| January 2032 | 0.00 |
| January 2033 | 0.00 |
| January 2034 | 0.00 |
| January 2035 | 0.00 |
| Total | |
| January 2011 | 0.00 |
| January 2012 | 0.00 |
| January 2013 | 0.00 |
| January 2014 | 0.00 |
| January 2015 | 0.00 |
| January 2016 | 0.00 |
| January 2017 | 0.00 |
| January 2018 | 0.00 |
| January 2019 | 0.00 |
| January 2020 | 0.00 |
| January 2021 | 0.00 |
| January 2022 | 0.00 |
| January 2023 | 0.00 |
| January 2024 | 0.00 |
| January 2025 | 0.00 |
| January 2026 | 0.00 |
| January 2027 | 0.00 |
| January 2028 | 0.00 |
| January 2029 | 0.00 |
| January 2030 | 0.00 |
| January 2031 | 0.00 |
| January 2032 | 0.00 |
| January 2033 | 0.00 |
| January 2034 | 0.00 |
| January 2035 | 0.00 |
| Total | |
| January 2011 | 0.00 |
| January 2012 | 0.00 |
| January 2013 | 0.00 |
| January 2014 | 0.00 |
| January 2015 | 0.00 |
| January 2016 | 0.00 |
| January 2017 | 0.00 |
| January 2018 | 0.00 |
| January 2019 | 0.00 |
| January 2020 | 0.00 |
| January 2021 | 0.00 |
| January 2022 | 0.00 |
| January 2023 | 0.00 |
| January 2024 | 0.00 |
| January 2025 | 0.00 |
| January 2026 | 0.00 |
| January 2027 | 0.00 |
| January 2028 | 0.00 |
| January 2029 | 0.00 |
| January 2030 | 0.00 |
| January 2031 | 0.00 |
| January 2032 | 0.00 |
| January 2033 | 0.00 |
| January 2034 | 0.00 |
| January 2035 | 0.00 |
| Construction | Salvage | OtherCapital | Total | |
| January 2011 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2012 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2013 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2014 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2015 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2016 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2017 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2018 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2019 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2020 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2021 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2022 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2023 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2024 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2025 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2026 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2027 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2028 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2029 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2030 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2031 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2032 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2033 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2034 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2035 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maintenance | Repair | Operation | Replacement | MinorOverhaul | MajorOverhaul | OtherOperational | Water | Energy | Total | |
| January 2011 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2012 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2013 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2014 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2015 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2016 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2017 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2018 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2019 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2020 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2021 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2022 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2023 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2024 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2025 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2026 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2027 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2028 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2029 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2030 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2031 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2032 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2033 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2034 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2035 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maintenance | Repair | Operation | Replacement | MinorOverhaul | MajorOverhaul | OtherOperational | Water | Energy | Total | |
| January 2011 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2012 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2013 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2014 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2015 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2016 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2017 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2018 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2019 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2020 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2021 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2022 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2023 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2024 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2025 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2026 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2027 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2028 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2029 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2030 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2031 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2032 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2033 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2034 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2035 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January | February | March | April | May | June | July | August | September | October | November | December | |
| 2011 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2012 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2013 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2014 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2015 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2016 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2017 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2018 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2019 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2020 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2021 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2022 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2023 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2024 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2025 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2026 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2027 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2028 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2029 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2030 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2031 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2032 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2033 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2034 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2035 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Category | Kind | Cost | Present Value | Present Value Factor | |
| DEFAULT COST | Construction | Nonrecurring | 0.00 | 0.00 | - |
| TOTAL | 0.00 |
| Present Value | |
| Maintenance | 0.00 |
| Repair | 0.00 |
| Operation | 0.00 |
| Replacement | 0.00 |
| Minor Overhaul | 0.00 |
| Major Overhaul | 0.00 |
| Other Operational | 0.00 |
| Water | 0.00 |
| Energy | 0.00 |
| Total Operation | 0.00 |
| Construction | 0.00 |
| Salvage | 0.00 |
| Other Capital | 0.00 |
| Total Capital | 0.00 |
| Total Energy | 0.00 |
| Grand Total | 0.00 |
| Total Cost (Without Escalation) | Total Cost (With Escalation) | Present Value of Costs | |
| January 2011 | 0.00 | 0.00 | 0.00 |
| January 2012 | 0.00 | 0.00 | 0.00 |
| January 2013 | 0.00 | 0.00 | 0.00 |
| January 2014 | 0.00 | 0.00 | 0.00 |
| January 2015 | 0.00 | 0.00 | 0.00 |
| January 2016 | 0.00 | 0.00 | 0.00 |
| January 2017 | 0.00 | 0.00 | 0.00 |
| January 2018 | 0.00 | 0.00 | 0.00 |
| January 2019 | 0.00 | 0.00 | 0.00 |
| January 2020 | 0.00 | 0.00 | 0.00 |
| January 2021 | 0.00 | 0.00 | 0.00 |
| January 2022 | 0.00 | 0.00 | 0.00 |
| January 2023 | 0.00 | 0.00 | 0.00 |
| January 2024 | 0.00 | 0.00 | 0.00 |
| January 2025 | 0.00 | 0.00 | 0.00 |
| January 2026 | 0.00 | 0.00 | 0.00 |
| January 2027 | 0.00 | 0.00 | 0.00 |
| January 2028 | 0.00 | 0.00 | 0.00 |
| January 2029 | 0.00 | 0.00 | 0.00 |
| January 2030 | 0.00 | 0.00 | 0.00 |
| January 2031 | 0.00 | 0.00 | 0.00 |
| January 2032 | 0.00 | 0.00 | 0.00 |
| January 2033 | 0.00 | 0.00 | 0.00 |
| January 2034 | 0.00 | 0.00 | 0.00 |
| January 2035 | 0.00 | 0.00 | 0.00 |
| TOTAL | 0.00 |