Table of Contents

Program Version:EnergyPlus, Version 24.1.0-9d7789a3ac, YMD=2024.09.12 18:15

Tabular Output Report in Format: HTML

Building: Building 1

Environment: RUN PERIOD 1 ** MILAN - ITA IWEC Data WMO#=160660

Simulation Timestamp: 2024-09-12 18:15:00


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 213.08 630.41 733.04
Net Site Energy 213.08 630.41 733.04
Total Source Energy 718.58 2125.97 2472.06
Net Source Energy 718.58 2125.97 2472.06


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating Water 3.613
District Heating Steam 1.200
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil No 1 1.050
Fuel Oil No 2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 338.00
Net Conditioned Building Area 290.68
Unconditioned Building Area 47.32


End Uses

Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating Water [GJ] District Heating Steam [GJ] Water [m3]
Heating 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 144.38 0.00 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9.80 0.00 0.00 0.00
Interior Lighting 26.44 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 32.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                             
Total End Uses 58.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9.80 144.38 0.00 0.00
Note: District heating water appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating Water [GJ] District Heating Steam [GJ] Water [m3]
Heating General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 144.38 0.00 0.00
Cooling General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9.80 0.00 0.00 0.00
Interior Lighting General 26.44 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment General 32.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Space Type

Space Type Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating Water [GJ] District Heating Steam [GJ] Water [m3]
Heating Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 144.38 0.00 0.00
Cooling Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9.80 0.00 0.00 0.00
Interior Lighting MIDRISEAPARTMENT APARTMENT 11.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  MIDRISEAPARTMENT CORRIDOR 14.78 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MIDRISEAPARTMENT APARTMENT 32.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Water Intensity [MJ/m2] District Heating Steam Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 90.96 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 33.71 496.70 0.00 0.00
Other 111.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 202.63 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 33.71 496.70 0.00 0.00


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Water Intensity [MJ/m2] District Heating Steam Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 78.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00  
HVAC 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.99 427.16 0.00  
Other 96.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00  
Total 174.26 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.99 427.16 0.00  


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.000 0.00
High Temperature Geothermal* 0.000 0.00
Photovoltaic Power 0.000 0.00
Wind Power 0.000 0.00
Power Conversion 0.000 0.00
Net Decrease in On-Site Storage 0.000 0.00
Total On-Site Electric Sources 0.000 0.00
     
Electricity Coming From Utility 58.900 100.00
Surplus Electricity Going To Utility 0.000 0.00
Net Electricity From Utility 58.900 100.00
     
Total On-Site and Utility Electric Sources 58.900 100.00
Total Electricity End Uses 58.900 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 -
Condensate Collection 0.00 -
Groundwater Well 0.00 -
Total On Site Water Sources 0.00 -
- - -
Initial Storage 0.00 -
Final Storage 0.00 -
Change in Storage 0.00 -
- - -
Water Supplied by Utility 0.00 -
- - -
Total On Site, Change in Storage, and Utility Water Sources 0.00 -
Total Water End Uses 0.00 -


Setpoint Not Met Criteria

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Comfort and Setpoint Not Met Summary

Facility [Hours]
Time Setpoint Not Met During Occupied Heating 0.00
Time Setpoint Not Met During Occupied Cooling 0.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 7123.67


Note 1: An asterisk (*) indicates that the feature is not yet implemented.

Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Adaptive Comfort Summary
Initialization Summary
Annual Heat Emissions Summary
Annual Thermal Resilience Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
Coil Sizing Details
System Summary
Outdoor Air Summary
Outdoor Air Details
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
LEED Summary
Annual CO2 Resilience Summary
Annual Visual Resilience Summary

BUILDING ENERGY PERFORMANCE - ELECTRICITY

| Meter |

BUILDING ENERGY PERFORMANCE - DISTRICT HEATING WATER

| Meter |

BUILDING ENERGY PERFORMANCE - DISTRICT COOLING

| Meter |

BUILDING ENERGY PERFORMANCE - ELECTRICITY PEAK DEMAND

| Meter |

BUILDING ENERGY PERFORMANCE - DISTRICT HEATING WATER PEAK DEMAND

| Meter |

BUILDING ENERGY PERFORMANCE - DISTRICT COOLING PEAK DEMAND

| Meter |

Life-Cycle Cost Report

| Entire Facility |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

General

Value
Program Version and Build EnergyPlus, Version 24.1.0-9d7789a3ac, YMD=2024.09.12 18:15
RunPeriod RUN PERIOD 1
Weather File MILAN - ITA IWEC Data WMO#=160660
Latitude [deg] 45.62
Longitude [deg] 8.73
Elevation [m] 211.00
Time Zone 1.00
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 280.80 70.20 70.20 70.20 70.20
Above Ground Wall Area [m2] 280.80 70.20 70.20 70.20 70.20
Window Opening Area [m2] 39.36 11.20 4.48 11.20 12.48
Gross Window-Wall Ratio [%] 14.02 15.95 6.38 15.95 17.78
Above Ground Window-Wall Ratio [%] 14.02 15.95 6.38 15.95 17.78


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 220.05 55.08 70.20 70.20 24.57
Above Ground Wall Area [m2] 220.05 55.08 70.20 70.20 24.57
Window Opening Area [m2] 31.36 11.20 4.48 11.20 4.48
Gross Window-Wall Ratio [%] 14.25 20.33 6.38 15.95 18.23
Above Ground Window-Wall Ratio [%] 14.25 20.33 6.38 15.95 18.23


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 169.00
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Above Ground Gross Wall Area [m2] Underground Gross Wall Area [m2] Window Glass Area [m2] Opening Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
TZ_0-A1.B 19.22 Yes Yes 51.89 1.00 22.68 0.00 2.24 2.24 3.8750 35.32 5.3820
TZ_0-A1.LK 37.29 Yes Yes 100.68 1.00 15.25 0.00 3.36 3.36 3.8750 35.32 5.3820
TZ_0-A1.W 10.81 Yes Yes 29.19 1.00 7.43 0.00 1.12 1.12 3.8750 35.32 5.3820
TZ_0-A2.B 18.31 Yes Yes 49.43 1.00 22.14 0.00 2.24 2.24 3.8750 35.32 5.3820
TZ_0-A2.LK 48.90 Yes Yes 132.03 1.00 35.10 0.00 5.60 5.60 3.8750 35.32 5.3820
TZ_0-A2.W 10.81 Yes Yes 29.19 1.00 7.43 0.00 1.12 1.12 3.8750 35.32 5.3820
TZ_0-H 23.66 No Yes 63.88 1.00 30.38 0.00 5.76 5.76 9.9028   0.0000
TZ_1-A3.B1 19.22 Yes Yes 51.89 1.00 22.68 0.00 2.24 2.24 3.8750 35.32 5.3820
TZ_1-A3.B2 18.31 Yes Yes 49.43 1.00 22.14 0.00 2.24 2.24 3.8750 35.32 5.3820
TZ_1-A3.LK 86.19 Yes Yes 232.71 1.00 50.36 0.00 8.96 8.96 3.8750 35.32 5.3820
TZ_1-A3.W1 10.81 Yes Yes 29.19 1.00 7.43 0.00 1.12 1.12 3.8750 35.32 5.3820
TZ_1-A3.W2 10.81 Yes Yes 29.19 1.00 7.43 0.00 1.12 1.12 3.8750 35.32 5.3820
TZ_1-H 23.66 No Yes 63.88 1.00 30.38 0.00 2.24 2.24 9.9028   0.0000
Total 338.00     912.60   280.80 0.00 39.36 39.36 4.7189 41.07 4.6285
Conditioned Total 290.68     784.84   220.05 0.00 31.36 31.36 3.8750 35.32 5.3820
Unconditioned Total 47.32     127.76   60.75 0.00 8.00 8.00 9.9028   0.0000
Not Part of Total 0.00     0.00   0.00 0.00 0.00 0.00      


Space Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Multipliers Zone Name Space Type Radiant/Solar Enclosure Name Lighting [W/m2] People [m2 per person] Plug and Process [W/m2] Tags
0-A1.B 19.22 Yes Yes 1.00 TZ_0-A1.B MIDRISEAPARTMENT APARTMENT 0-A1.B 3.8750 35.32 5.3820  
0-A1.LK 37.29 Yes Yes 1.00 TZ_0-A1.LK MIDRISEAPARTMENT APARTMENT 0-A1.LK 3.8750 35.32 5.3820  
0-A1.W 10.81 Yes Yes 1.00 TZ_0-A1.W MIDRISEAPARTMENT APARTMENT 0-A1.W 3.8750 35.32 5.3820  
0-A2.B 18.31 Yes Yes 1.00 TZ_0-A2.B MIDRISEAPARTMENT APARTMENT 0-A2.B 3.8750 35.32 5.3820  
0-A2.LK 48.90 Yes Yes 1.00 TZ_0-A2.LK MIDRISEAPARTMENT APARTMENT 0-A2.LK 3.8750 35.32 5.3820  
0-A2.W 10.81 Yes Yes 1.00 TZ_0-A2.W MIDRISEAPARTMENT APARTMENT 0-A2.W 3.8750 35.32 5.3820  
0-H 23.66 No Yes 1.00 TZ_0-H MIDRISEAPARTMENT CORRIDOR 0-H 9.9028 0.00 0.0000  
1-A3.B1 19.22 Yes Yes 1.00 TZ_1-A3.B1 MIDRISEAPARTMENT APARTMENT 1-A3.B1 3.8750 35.32 5.3820  
1-A3.B2 18.31 Yes Yes 1.00 TZ_1-A3.B2 MIDRISEAPARTMENT APARTMENT 1-A3.B2 3.8750 35.32 5.3820  
1-A3.LK 86.19 Yes Yes 1.00 TZ_1-A3.LK MIDRISEAPARTMENT APARTMENT 1-A3.LK 3.8750 35.32 5.3820  
1-A3.W1 10.81 Yes Yes 1.00 TZ_1-A3.W1 MIDRISEAPARTMENT APARTMENT 1-A3.W1 3.8750 35.32 5.3820  
1-A3.W2 10.81 Yes Yes 1.00 TZ_1-A3.W2 MIDRISEAPARTMENT APARTMENT 1-A3.W2 3.8750 35.32 5.3820  
1-H 23.66 No Yes 1.00 TZ_1-H MIDRISEAPARTMENT CORRIDOR 1-H 9.9028 0.00 0.0000  
Total 338.00             4.7189 41.07 4.6285  
Conditioned Total 290.68             3.8750 35.32 5.3820  
Unconditioned Total 47.32             9.9028 0.00 0.0000  
Not Part of Total 0.00             0.0000 0.00 0.0000  


Space Type Summary

Total Area [m2] Conditioned Area [m2] Unconditioned Area [m2] Not Part of Total Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
MIDRISEAPARTMENT APARTMENT 290.68 290.68 0.00 0.00 3.8750 35.32 5.3820
MIDRISEAPARTMENT CORRIDOR 47.32 0.00 47.32 0.00 9.9028 0.00 0.0000
Total 338.00 290.68 47.32 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

End Uses

Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] District Heating Water [W] District Heating Steam [W] Water [m3/s]
Time of Peak 01-JAN-19:20 - - - - - - - - - 21-JUL-18:20 30-JAN-03:10 - -
Heating 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 22048.54 0.00 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9110.11 0.00 0.00 0.00
Interior Lighting 1579.22 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                             
Total End Uses 3034.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9110.11 22048.54 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] District Heating Water [W] District Heating Steam [W] Water [m3/s]
Heating General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 22048.54 0.00 0.00
Cooling General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9110.11 0.00 0.00 0.00
Interior Lighting General 1579.22 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment General 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Gasoline [GJ] Source Diesel [GJ] Source Coal [GJ] Source Fuel Oil No 1 [GJ] Source Fuel Oil No 2 [GJ] Source Propane [GJ] Source Other Fuel 1 [GJ] Source Other Fuel 2 [GJ] Source District Cooling [GJ] Source District Heating Water [GJ] Source District Heating Steam [GJ]
Heating 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 521.70 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10.34 0.00 0.00
Interior Lighting 83.74 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 102.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total Source Energy End Use Components 186.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10.34 521.70 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating Water [MJ/m2] Source District Heating Steam [MJ/m2]
Heating 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1794.76 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 35.58 0.00 0.00
Interior Lighting 288.08 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 353.64 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total Source Energy End Use Components 641.72 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 35.58 1794.76 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating Water [MJ/m2] Source District Heating Steam [MJ/m2]
Heating 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1543.49 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 30.60 0.00 0.00
Interior Lighting 247.75 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 304.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total Source Energy End Use Components 551.88 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 30.60 1543.49 0.00



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00


Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
FACE 23 FACE 24 |
FACE 18 FACE 19 |
FACE 39 FACE 40 |
FACE 77 FACE 78 |
FACE 44 FACE 45 |
FACE 54 FACE 55 |
FACE 65 FACE 66 |
FACE 7 FACE 8 |
FACE 110 FACE 111 |
FACE 150 FACE 151 |
FACE 104 FACE 105 |
FACE 89 FACE 90 |
FACE 94 FACE 95 |
FACE 126 FACE 127 |
FACE 138 FACE 139 |
FACE 84 FACE 85 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: Initialization Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Version

Version ID
1 24.1


Timesteps per Hour

#TimeSteps Minutes per TimeStep {minutes}
1 6 10


System Convergence Limits

Minimum System TimeStep {minutes} Max HVAC Iterations Minimum Plant Iterations Maximum Plant Iterations
1 1 20 2 8


Simulation Control

Do Zone Sizing Do System Sizing Do Plant Sizing Do Design Days Do Weather Simulation Do HVAC Sizing Simulation
1 No No No Yes Yes No


Performance Precision Tradeoffs

Use Coil Direct Simulation Zone Radiant Exchange Algorithm Override Mode Number of Timestep In Hour Force Euler Method Minimum Number of Warmup Days Force Suppress All Begin Environment Resets Minimum System Timestep MaxZoneTempDiff MaxAllowedDelTemp
1 No ScriptF Normal 6 No 1 No 1.0 0.300 2.0000E-003


Output Reporting Tolerances

Tolerance for Time Heating Setpoint Not Met Tolerance for Zone Cooling Setpoint Not Met Time
1 0.200 0.200


Site:GroundTemperature:BuildingSurface

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00


Site:GroundTemperature:FCfactorMethod

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 2.39 1.46 3.10 5.66 12.35 17.52 21.00 22.06 20.26 16.25 10.89 5.91


Site:GroundTemperature:Shallow

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00


Site:GroundTemperature:Deep

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00


Site:GroundReflectance

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:SnowModifier

Normal Daylighting {dimensionless}
1 1.000 1.000


Site:GroundReflectance:Snow

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:Snow:Daylighting

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Environment:Weather Station

Wind Sensor Height Above Ground {m} Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Sensor Height Above Ground {m} Wind Speed Modifier Coefficient-Internal Temperature Modifier Coefficient-Internal
1 10.000 0.140 270.000 1.500 1.586 9.750E-003


Site:Location

Location Name Latitude {N+/S- Deg} Longitude {E+/W- Deg} Time Zone Number {GMT+/-} Elevation {m} Standard Pressure at Elevation {Pa} Standard RhoAir at Elevation
1 MILAN - ITA IWEC Data WMO#=160660 45.62 8.73 1.00 211.00 98816 1.1745


Site Water Mains Temperature Information

Calculation Method{} Water Mains Temperature Schedule Name{} Annual Average Outdoor Air Temperature{C} Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} Fixed Default Water Mains Temperature{C}
1 FixedDefault NA NA NA 10.0


Building Information

Building Name North Axis {deg} Terrain Loads Convergence Tolerance Value Temperature Convergence Tolerance Value Solar Distribution Maximum Number of Warmup Days Minimum Number of Warmup Days
1 Building 1 0.000 Suburbs 4.00000E-002 0.40000 FullExterior 25 1


Inside Convection Algorithm

Algorithm {Simple
TARP
CeilingDiffuser
AdaptiveConvectionAlgorithm}
1 TARP


Outside Convection Algorithm

Algorithm {SimpleCombined
TARP
MoWitt
DOE-2
AdaptiveConvectionAlgorithm}
1 DOE-2


Sky Radiance Distribution

Value {Anisotropic}
1 Anisotropic


Zone Air Solution Algorithm

Algorithm {ThirdOrderBackwardDifference
AnalyticalSolution
EulerMethod}
Space Heat Balance Sizing

Space Heat Balance Simulation

1 ThirdOrderBackwardDifference No No


Zone Air Carbon Dioxide Balance Simulation

Simulation {Yes/No} Carbon Dioxide Concentration
1 No N/A


Zone Air Generic Contaminant Balance Simulation

Simulation {Yes/No} Generic Contaminant Concentration
1 No N/A


Zone Air Mass Flow Balance Simulation

Enforce Mass Balance



Adjust Zone Mixing and Return {AdjustMixingOnly
AdjustReturnOnly
AdjustMixingThenReturn
AdjustReturnThenMixing
None}
Adjust Zone Infiltration {AddInfiltration
AdjustInfiltration
None}

Infiltration Zones {MixingSourceZonesOnly
AllZones}


1 No N/A N/A N/A


HVACSystemRootFindingAlgorithm

Value {RegulaFalsi
Bisection
BisectionThenRegulaFalsi
RegulaFalsiThenBisection}
1 RegulaFalsi


Environment:Site Atmospheric Variation

Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Gradient Coefficient {K/m}
1 0.220 370.000 6.500000E-003


Surface Geometry

Starting Corner Vertex Input Direction Coordinate System Daylight Reference Point Coordinate System Rectangular (Simple) Surface Coordinate System
1 UpperLeftCorner Counterclockwise RelativeCoordinateSystem RelativeCoordinateSystem RelativeToZoneOrigin


Surface Heat Transfer Algorithm

Value {CTF - ConductionTransferFunction
EMPD - MoisturePenetrationDepthConductionTransferFunction
CondFD - ConductionFiniteDifference
HAMT - CombinedHeatAndMoistureFiniteElement} - Description
Inside Surface Max Temperature Limit{C}


Surface Convection Coefficient Lower Limit {W/m2-K}


Surface Convection Coefficient Upper Limit {W/m2-K}


1 CTF - ConductionTransferFunction 200 0.10 1000.0


Shading Summary

Number of Fixed Detached Shades Number of Building Detached Shades Number of Attached Shades
1 0 0 0


Zone Summary

Number of Zones Number of Zone Surfaces Number of SubSurfaces
1 13 153 38


Zone Information

Zone Name North Axis {deg} Origin X-Coordinate {m} Origin Y-Coordinate {m} Origin Z-Coordinate {m} Centroid X-Coordinate {m} Centroid Y-Coordinate {m} Centroid Z-Coordinate {m} Type Zone Multiplier Zone List Multiplier Minimum X {m} Maximum X {m} Minimum Y {m} Maximum Y {m} Minimum Z {m} Maximum Z {m} Ceiling Height {m} Volume {m3} Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} Floor Area {m2} Exterior Gross Wall Area {m2} Exterior Net Wall Area {m2} Exterior Window Area {m2} Number of Surfaces Number of SubSurfaces Number of Shading SubSurfaces Part of Total Building Area
1 TZ_0-A1.B 0.0 0.00 0.00 0.00 10.56 10.46 1.35 1 1 1 8.45 13.00 8.15 13.00 0.00 2.70 2.70 51.89 TARP DOE-2 19.22 22.68 20.44 2.24 8 2 0 Yes
2 TZ_0-A1.LK 0.0 0.00 0.00 0.00 5.63 9.70 1.35 1 1 1 2.80 8.45 6.40 13.00 0.00 2.70 2.70 100.68 TARP DOE-2 37.29 15.26 11.90 3.36 7 3 0 Yes
3 TZ_0-A1.W 0.0 0.00 0.00 0.00 10.73 7.74 1.35 1 1 1 8.45 13.00 6.40 9.15 0.00 2.70 2.70 29.19 TARP DOE-2 10.81 7.43 6.31 1.12 9 3 0 Yes
4 TZ_0-A2.B 0.0 0.00 0.00 0.00 10.55 2.42 1.35 1 1 1 8.45 13.00 0.00 4.65 0.00 2.70 2.70 49.43 TARP DOE-2 18.31 22.14 19.90 2.24 9 2 0 Yes
5 TZ_0-A2.LK 0.0 0.00 0.00 0.00 4.04 3.37 1.35 1 1 1 0.00 8.45 0.00 6.40 0.00 2.70 2.70 132.03 TARP DOE-2 48.90 35.10 29.50 5.60 10 4 0 Yes
6 TZ_0-A2.W 0.0 0.00 0.00 0.00 10.73 5.06 1.35 1 1 1 8.45 13.00 3.65 6.40 0.00 2.70 2.70 29.19 TARP DOE-2 10.81 7.43 6.31 1.12 9 3 0 Yes
7 TZ_0-H 0.0 0.00 0.00 0.00 1.40 8.78 1.35 1 1 1 0.00 2.80 4.55 13.00 0.00 2.70 2.70 63.88 TARP DOE-2 23.66 30.38 24.62 5.76 7 3 0 Yes
8 TZ_1-A3.B1 0.0 0.00 0.00 0.00 10.56 10.46 4.05 1 1 1 8.45 13.00 8.15 13.00 2.70 5.40 2.70 51.89 TARP DOE-2 19.22 22.68 20.44 2.24 9 2 0 Yes
9 TZ_1-A3.B2 0.0 0.00 0.00 0.00 10.55 2.42 4.05 1 1 1 8.45 13.00 0.00 4.65 2.70 5.40 2.70 49.43 TARP DOE-2 18.31 22.14 19.90 2.24 9 2 0 Yes
10 TZ_1-A3.LK 0.0 0.00 0.00 0.00 4.41 6.01 4.05 1 1 1 0.00 8.45 0.00 13.00 2.70 5.40 2.70 232.71 TARP DOE-2 86.19 50.36 41.40 8.96 14 6 0 Yes
11 TZ_1-A3.W1 0.0 0.00 0.00 0.00 10.73 7.74 4.05 1 1 1 8.45 13.00 6.40 9.15 2.70 5.40 2.70 29.19 TARP DOE-2 10.81 7.43 6.31 1.12 9 3 0 Yes
12 TZ_1-A3.W2 0.0 0.00 0.00 0.00 10.73 5.06 4.05 1 1 1 8.45 13.00 3.65 6.40 2.70 5.40 2.70 29.19 TARP DOE-2 10.81 7.43 6.31 1.12 9 3 0 Yes
13 TZ_1-H 0.0 0.00 0.00 0.00 1.40 8.78 4.05 1 1 1 0.00 2.80 4.55 13.00 2.70 5.40 2.70 63.88 TARP DOE-2 23.66 30.38 28.14 2.24 6 2 0 Yes


Zone Internal Gains Nominal

Zone Name Floor Area {m2} # Occupants Area per Occupant {m2/person} Occupant per Area {person/m2} Interior Lighting {W/m2} Electric Load {W/m2} Gas Load {W/m2} Other Load {W/m2} Hot Water Eq {W/m2} Steam Equipment {W/m2} Sum Loads per Area {W/m2} Outdoor Controlled Baseboard Heat
1 TZ_0-A1.B 19.22 0.5 35.324 2.831E-002 3.875 5.382 0.000 0.000 0.000 0.000 9.257 No
2 TZ_0-A1.LK 37.29 1.1 35.324 2.831E-002 3.875 5.382 0.000 0.000 0.000 0.000 9.257 No
3 TZ_0-A1.W 10.81 0.3 35.324 2.831E-002 3.875 5.382 0.000 0.000 0.000 0.000 9.257 No
4 TZ_0-A2.B 18.31 0.5 35.324 2.831E-002 3.875 5.382 0.000 0.000 0.000 0.000 9.257 No
5 TZ_0-A2.LK 48.90 1.4 35.324 2.831E-002 3.875 5.382 0.000 0.000 0.000 0.000 9.257 No
6 TZ_0-A2.W 10.81 0.3 35.324 2.831E-002 3.875 5.382 0.000 0.000 0.000 0.000 9.257 No
7 TZ_0-H 23.66 0.0 N/A 0.000 9.903 0.000 0.000 0.000 0.000 0.000 9.903 No
8 TZ_1-A3.B1 19.22 0.5 35.324 2.831E-002 3.875 5.382 0.000 0.000 0.000 0.000 9.257 No
9 TZ_1-A3.B2 18.31 0.5 35.324 2.831E-002 3.875 5.382 0.000 0.000 0.000 0.000 9.257 No
10 TZ_1-A3.LK 86.19 2.4 35.324 2.831E-002 3.875 5.382 0.000 0.000 0.000 0.000 9.257 No
11 TZ_1-A3.W1 10.81 0.3 35.324 2.831E-002 3.875 5.382 0.000 0.000 0.000 0.000 9.257 No
12 TZ_1-A3.W2 10.81 0.3 35.324 2.831E-002 3.875 5.382 0.000 0.000 0.000 0.000 9.257 No
13 TZ_1-H 23.66 0.0 N/A 0.000 9.903 0.000 0.000 0.000 0.000 0.000 9.903 No


People Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Number of People {} People/Floor Area {person/m2} Floor Area per person {m2/person} Fraction Radiant Fraction Convected Sensible Fraction Calculation Activity level ASHRAE 55 Warnings Carbon Dioxide Generation Rate Nominal Minimum Number of People Nominal Maximum Number of People
1 1-A3.B1 MIDRISEAPARTMENT APARTMENT PEOPLE MIDRISEAPARTMENT APARTMENT OCC TZ_1-A3.B1 19.22 0.5 0.5 2.831E-002 35.324 0.300 0.700 AutoCalculate MIDRISEAPARTMENT ACTIVITY No 3.8200E-008 0 1
2 0-A2.B MIDRISEAPARTMENT APARTMENT PEOPLE MIDRISEAPARTMENT APARTMENT OCC TZ_0-A2.B 18.31 0.5 0.5 2.831E-002 35.324 0.300 0.700 AutoCalculate MIDRISEAPARTMENT ACTIVITY No 3.8200E-008 0 1
3 0-A1.LK MIDRISEAPARTMENT APARTMENT PEOPLE MIDRISEAPARTMENT APARTMENT OCC TZ_0-A1.LK 37.29 1.1 1.1 2.831E-002 35.324 0.300 0.700 AutoCalculate MIDRISEAPARTMENT ACTIVITY No 3.8200E-008 0 1
4 0-A2.LK MIDRISEAPARTMENT APARTMENT PEOPLE MIDRISEAPARTMENT APARTMENT OCC TZ_0-A2.LK 48.90 1.4 1.4 2.831E-002 35.324 0.300 0.700 AutoCalculate MIDRISEAPARTMENT ACTIVITY No 3.8200E-008 0 1
5 1-A3.W1 MIDRISEAPARTMENT APARTMENT PEOPLE MIDRISEAPARTMENT APARTMENT OCC TZ_1-A3.W1 10.81 0.3 0.3 2.831E-002 35.324 0.300 0.700 AutoCalculate MIDRISEAPARTMENT ACTIVITY No 3.8200E-008 8E-002 0
6 0-A1.B MIDRISEAPARTMENT APARTMENT PEOPLE MIDRISEAPARTMENT APARTMENT OCC TZ_0-A1.B 19.22 0.5 0.5 2.831E-002 35.324 0.300 0.700 AutoCalculate MIDRISEAPARTMENT ACTIVITY No 3.8200E-008 0 1
7 0-A1.W MIDRISEAPARTMENT APARTMENT PEOPLE MIDRISEAPARTMENT APARTMENT OCC TZ_0-A1.W 10.81 0.3 0.3 2.831E-002 35.324 0.300 0.700 AutoCalculate MIDRISEAPARTMENT ACTIVITY No 3.8200E-008 8E-002 0
8 0-A2.W MIDRISEAPARTMENT APARTMENT PEOPLE MIDRISEAPARTMENT APARTMENT OCC TZ_0-A2.W 10.81 0.3 0.3 2.831E-002 35.324 0.300 0.700 AutoCalculate MIDRISEAPARTMENT ACTIVITY No 3.8200E-008 8E-002 0
9 1-A3.B2 MIDRISEAPARTMENT APARTMENT PEOPLE MIDRISEAPARTMENT APARTMENT OCC TZ_1-A3.B2 18.31 0.5 0.5 2.831E-002 35.324 0.300 0.700 AutoCalculate MIDRISEAPARTMENT ACTIVITY No 3.8200E-008 0 1
10 1-A3.LK MIDRISEAPARTMENT APARTMENT PEOPLE MIDRISEAPARTMENT APARTMENT OCC TZ_1-A3.LK 86.19 2.4 2.4 2.831E-002 35.324 0.300 0.700 AutoCalculate MIDRISEAPARTMENT ACTIVITY No 3.8200E-008 1 2
11 1-A3.W2 MIDRISEAPARTMENT APARTMENT PEOPLE MIDRISEAPARTMENT APARTMENT OCC TZ_1-A3.W2 10.81 0.3 0.3 2.831E-002 35.324 0.300 0.700 AutoCalculate MIDRISEAPARTMENT ACTIVITY No 3.8200E-008 8E-002 0


Lights Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Lighting Level {W} Lights/Floor Area {W/m2} Lights per person {W/person} Fraction Return Air Fraction Radiant Fraction Short Wave Fraction Convected Fraction Replaceable End-Use Category Nominal Minimum Lighting Level {W} Nominal Maximum Lighting Level {W}
1 1-A3.B1 MIDRISEAPARTMENT APARTMENT LIGHTS MIDRISEAPARTMENT APARTMENT LIGHT TZ_1-A3.B1 19.22 0.5 74.468 3.875 136.882 0.000 0.000 0.000 1.000 0.000 General 4.989 74.468
2 0-A2.B MIDRISEAPARTMENT APARTMENT LIGHTS MIDRISEAPARTMENT APARTMENT LIGHT TZ_0-A2.B 18.31 0.5 70.942 3.875 136.882 0.000 0.000 0.000 1.000 0.000 General 4.753 70.942
3 0-A1.LK MIDRISEAPARTMENT APARTMENT LIGHTS MIDRISEAPARTMENT APARTMENT LIGHT TZ_0-A1.LK 37.29 1.1 144.499 3.875 136.882 0.000 0.000 0.000 1.000 0.000 General 9.681 144.499
4 0-A2.LK MIDRISEAPARTMENT APARTMENT LIGHTS MIDRISEAPARTMENT APARTMENT LIGHT TZ_0-A2.LK 48.90 1.4 189.488 3.875 136.882 0.000 0.000 0.000 1.000 0.000 General 12.696 189.488
5 1-A3.W1 MIDRISEAPARTMENT APARTMENT LIGHTS MIDRISEAPARTMENT APARTMENT LIGHT TZ_1-A3.W1 10.81 0.3 41.899 3.875 136.882 0.000 0.000 0.000 1.000 0.000 General 2.807 41.899
6 0-A1.B MIDRISEAPARTMENT APARTMENT LIGHTS MIDRISEAPARTMENT APARTMENT LIGHT TZ_0-A1.B 19.22 0.5 74.468 3.875 136.882 0.000 0.000 0.000 1.000 0.000 General 4.989 74.468
7 0-A1.W MIDRISEAPARTMENT APARTMENT LIGHTS MIDRISEAPARTMENT APARTMENT LIGHT TZ_0-A1.W 10.81 0.3 41.899 3.875 136.882 0.000 0.000 0.000 1.000 0.000 General 2.807 41.899
8 0-A2.W MIDRISEAPARTMENT APARTMENT LIGHTS MIDRISEAPARTMENT APARTMENT LIGHT TZ_0-A2.W 10.81 0.3 41.899 3.875 136.882 0.000 0.000 0.000 1.000 0.000 General 2.807 41.899
9 1-A3.B2 MIDRISEAPARTMENT APARTMENT LIGHTS MIDRISEAPARTMENT APARTMENT LIGHT TZ_1-A3.B2 18.31 0.5 70.942 3.875 136.882 0.000 0.000 0.000 1.000 0.000 General 4.753 70.942
10 1-A3.LK MIDRISEAPARTMENT APARTMENT LIGHTS MIDRISEAPARTMENT APARTMENT LIGHT TZ_1-A3.LK 86.19 2.4 333.987 3.875 136.882 0.000 0.000 0.000 1.000 0.000 General 22.377 333.987
11 1-A3.W2 MIDRISEAPARTMENT APARTMENT LIGHTS MIDRISEAPARTMENT APARTMENT LIGHT TZ_1-A3.W2 10.81 0.3 41.899 3.875 136.882 0.000 0.000 0.000 1.000 0.000 General 2.807 41.899
12 0-H MIDRISEAPARTMENT CORRIDOR LIGHTS MIDRISEAPARTMENT CORRIDOR LIGHT TZ_0-H 23.66 0.0 234.300 9.903 N/A 0.000 0.000 0.000 1.000 0.000 General 234.300 234.300
13 1-H MIDRISEAPARTMENT CORRIDOR LIGHTS MIDRISEAPARTMENT CORRIDOR LIGHT TZ_1-H 23.66 0.0 234.300 9.903 N/A 0.000 0.000 0.000 1.000 0.000 General 234.300 234.300


ElectricEquipment Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Equipment Level {W} Equipment/Floor Area {W/m2} Equipment per person {W/person} Fraction Latent Fraction Radiant Fraction Lost Fraction Convected End-Use SubCategory Nominal Minimum Equipment Level {W} Nominal Maximum Equipment Level {W}
1 1-A3.B1 MIDRISEAPARTMENT APARTMENT ELEC EQUIP APARTMENTMIDRISE EQP_APT_SCH TZ_1-A3.B1 19.22 0.5 103.428 5.382 190.114 0.000 0.500 0.000 0.500 General 39.303 103.428
2 0-A2.B MIDRISEAPARTMENT APARTMENT ELEC EQUIP APARTMENTMIDRISE EQP_APT_SCH TZ_0-A2.B 18.31 0.5 98.530 5.382 190.114 0.000 0.500 0.000 0.500 General 37.441 98.530
3 0-A1.LK MIDRISEAPARTMENT APARTMENT ELEC EQUIP APARTMENTMIDRISE EQP_APT_SCH TZ_0-A1.LK 37.29 1.1 200.693 5.382 190.114 0.000 0.500 0.000 0.500 General 76.263 200.693
4 0-A2.LK MIDRISEAPARTMENT APARTMENT ELEC EQUIP APARTMENTMIDRISE EQP_APT_SCH TZ_0-A2.LK 48.90 1.4 263.178 5.382 190.114 0.000 0.500 0.000 0.500 General 100.007 263.178
5 1-A3.W1 MIDRISEAPARTMENT APARTMENT ELEC EQUIP APARTMENTMIDRISE EQP_APT_SCH TZ_1-A3.W1 10.81 0.3 58.192 5.382 190.114 0.000 0.500 0.000 0.500 General 22.113 58.192
6 0-A1.B MIDRISEAPARTMENT APARTMENT ELEC EQUIP APARTMENTMIDRISE EQP_APT_SCH TZ_0-A1.B 19.22 0.5 103.428 5.382 190.114 0.000 0.500 0.000 0.500 General 39.303 103.428
7 0-A1.W MIDRISEAPARTMENT APARTMENT ELEC EQUIP APARTMENTMIDRISE EQP_APT_SCH TZ_0-A1.W 10.81 0.3 58.192 5.382 190.114 0.000 0.500 0.000 0.500 General 22.113 58.192
8 0-A2.W MIDRISEAPARTMENT APARTMENT ELEC EQUIP APARTMENTMIDRISE EQP_APT_SCH TZ_0-A2.W 10.81 0.3 58.192 5.382 190.114 0.000 0.500 0.000 0.500 General 22.113 58.192
9 1-A3.B2 MIDRISEAPARTMENT APARTMENT ELEC EQUIP APARTMENTMIDRISE EQP_APT_SCH TZ_1-A3.B2 18.31 0.5 98.530 5.382 190.114 0.000 0.500 0.000 0.500 General 37.441 98.530
10 1-A3.LK MIDRISEAPARTMENT APARTMENT ELEC EQUIP APARTMENTMIDRISE EQP_APT_SCH TZ_1-A3.LK 86.19 2.4 463.871 5.382 190.114 0.000 0.500 0.000 0.500 General 176.271 463.871
11 1-A3.W2 MIDRISEAPARTMENT APARTMENT ELEC EQUIP APARTMENTMIDRISE EQP_APT_SCH TZ_1-A3.W2 10.81 0.3 58.192 5.382 190.114 0.000 0.500 0.000 0.500 General 22.113 58.192


Shadowing/Sun Position Calculations Annual Simulations

Shading Calculation Method Shading Calculation Update Frequency Method Shading Calculation Update Frequency {days} Maximum Figures in Shadow Overlap Calculations {} Polygon Clipping Algorithm Pixel Counting Resolution Sky Diffuse Modeling Algorithm Output External Shading Calculation Results Disable Self-Shading Within Shading Zone Groups Disable Self-Shading From Shading Zone Groups to Other Zones
1 PolygonClipping Periodic 20 15000 SutherlandHodgman 512 SimpleSkyDiffuseModeling No No No


ZoneInfiltration Airflow Stats Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Design Volume Flow Rate {m3/s} Volume Flow Rate/Floor Area {m3/s-m2} Volume Flow Rate/Exterior Surface Area {m3/s-m2} ACH - Air Changes per Hour Equation A - Constant Term Coefficient {} Equation B - Temperature Term Coefficient {1/C} Equation C - Velocity Term Coefficient {s/m} Equation D - Velocity Squared Term Coefficient {s2/m2}
1 1-A3.B1 MIDRISEAPARTMENT APARTMENT INFILTRATION MIDRISEAPARTMENT INFIL TZ_1-A3.B1 19.22 0.5 2.569E-002 1.337E-003 6.132E-004 1.783 1.000 0.000 0.000 0.000
2 0-A2.B MIDRISEAPARTMENT APARTMENT INFILTRATION MIDRISEAPARTMENT INFIL TZ_0-A2.B 18.31 0.5 2.508E-002 1.370E-003 1.133E-003 1.827 1.000 0.000 0.000 0.000
3 0-A1.LK MIDRISEAPARTMENT APARTMENT INFILTRATION MIDRISEAPARTMENT INFIL TZ_0-A1.LK 37.29 1.1 1.728E-002 4.634E-004 1.133E-003 0.618 1.000 0.000 0.000 0.000
4 0-A2.LK MIDRISEAPARTMENT APARTMENT INFILTRATION MIDRISEAPARTMENT INFIL TZ_0-A2.LK 48.90 1.4 3.976E-002 8.131E-004 1.133E-003 1.084 1.000 0.000 0.000 0.000
5 1-A3.W1 MIDRISEAPARTMENT APARTMENT INFILTRATION MIDRISEAPARTMENT INFIL TZ_1-A3.W1 10.81 0.3 8.411E-003 7.779E-004 4.612E-004 1.037 1.000 0.000 0.000 0.000
6 0-A1.B MIDRISEAPARTMENT APARTMENT INFILTRATION MIDRISEAPARTMENT INFIL TZ_0-A1.B 19.22 0.5 2.569E-002 1.337E-003 1.133E-003 1.783 1.000 0.000 0.000 0.000
7 0-A1.W MIDRISEAPARTMENT APARTMENT INFILTRATION MIDRISEAPARTMENT INFIL TZ_0-A1.W 10.81 0.3 8.411E-003 7.779E-004 1.133E-003 1.037 1.000 0.000 0.000 0.000
8 0-A2.W MIDRISEAPARTMENT APARTMENT INFILTRATION MIDRISEAPARTMENT INFIL TZ_0-A2.W 10.81 0.3 8.411E-003 7.779E-004 1.133E-003 1.037 1.000 0.000 0.000 0.000
9 1-A3.B2 MIDRISEAPARTMENT APARTMENT INFILTRATION MIDRISEAPARTMENT INFIL TZ_1-A3.B2 18.31 0.5 2.508E-002 1.370E-003 6.201E-004 1.827 1.000 0.000 0.000 0.000
10 1-A3.LK MIDRISEAPARTMENT APARTMENT INFILTRATION MIDRISEAPARTMENT INFIL TZ_1-A3.LK 86.19 2.4 5.704E-002 6.618E-004 4.178E-004 0.882 1.000 0.000 0.000 0.000
11 1-A3.W2 MIDRISEAPARTMENT APARTMENT INFILTRATION MIDRISEAPARTMENT INFIL TZ_1-A3.W2 10.81 0.3 8.411E-003 7.779E-004 4.612E-004 1.037 1.000 0.000 0.000 0.000
12 0-H MIDRISEAPARTMENT CORRIDOR INFILTRATION MIDRISEAPARTMENT INFIL TZ_0-H 23.66 0.0 3.441E-002 1.454E-003 1.133E-003 1.939 1.000 0.000 0.000 0.000
13 1-H MIDRISEAPARTMENT CORRIDOR INFILTRATION MIDRISEAPARTMENT INFIL TZ_1-H 23.66 0.0 3.441E-002 1.454E-003 6.368E-004 1.939 1.000 0.000 0.000 0.000


ZoneVentilation Airflow Stats Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Design Volume Flow Rate {m3/s} Volume Flow Rate/Floor Area {m3/s-m2} Volume Flow Rate/person Area {m3/s-person} ACH - Air Changes per Hour Fan Type {Exhaust;Intake;Natural} Fan Pressure Rise {Pa} Fan Efficiency {} Equation A - Constant Term Coefficient {} Equation B - Temperature Term Coefficient {1/C} Equation C - Velocity Term Coefficient {s/m} Equation D - Velocity Squared Term Coefficient {s2/m2} Minimum Indoor Temperature{C}/Schedule Maximum Indoor Temperature{C}/Schedule Delta Temperature{C}/Schedule Minimum Outdoor Temperature{C}/Schedule Maximum Outdoor Temperature{C}/Schedule Maximum WindSpeed{m/s}
1 TZ_0-A1.B VENTILATION PER PERSON MIDRISEAPARTMENT APARTMENT OCC TZ_0-A1.B 19.22 0.5 9.243E-003 4.810E-004 1.699E-002 0.641 Natural 0.000 1.0 1.000 0.000 0.000 0.000 -100.00 100.00 -100.00 -100.00 100.00 40.00
2 TZ_0-A1.LK VENTILATION PER PERSON MIDRISEAPARTMENT APARTMENT OCC TZ_0-A1.LK 37.29 1.1 1.794E-002 4.810E-004 1.699E-002 0.641 Natural 0.000 1.0 1.000 0.000 0.000 0.000 -100.00 100.00 -100.00 -100.00 100.00 40.00
3 TZ_0-A1.W VENTILATION PER PERSON MIDRISEAPARTMENT APARTMENT OCC TZ_0-A1.W 10.81 0.3 5.201E-003 4.810E-004 1.699E-002 0.641 Natural 0.000 1.0 1.000 0.000 0.000 0.000 -100.00 100.00 -100.00 -100.00 100.00 40.00
4 TZ_0-A2.B VENTILATION PER PERSON MIDRISEAPARTMENT APARTMENT OCC TZ_0-A2.B 18.31 0.5 8.805E-003 4.810E-004 1.699E-002 0.641 Natural 0.000 1.0 1.000 0.000 0.000 0.000 -100.00 100.00 -100.00 -100.00 100.00 40.00
5 TZ_0-A2.LK VENTILATION PER PERSON MIDRISEAPARTMENT APARTMENT OCC TZ_0-A2.LK 48.90 1.4 2.352E-002 4.810E-004 1.699E-002 0.641 Natural 0.000 1.0 1.000 0.000 0.000 0.000 -100.00 100.00 -100.00 -100.00 100.00 40.00
6 TZ_0-A2.W VENTILATION PER PERSON MIDRISEAPARTMENT APARTMENT OCC TZ_0-A2.W 10.81 0.3 5.201E-003 4.810E-004 1.699E-002 0.641 Natural 0.000 1.0 1.000 0.000 0.000 0.000 -100.00 100.00 -100.00 -100.00 100.00 40.00
7 TZ_1-A3.B1 VENTILATION PER PERSON MIDRISEAPARTMENT APARTMENT OCC TZ_1-A3.B1 19.22 0.5 9.243E-003 4.810E-004 1.699E-002 0.641 Natural 0.000 1.0 1.000 0.000 0.000 0.000 -100.00 100.00 -100.00 -100.00 100.00 40.00
8 TZ_1-A3.B2 VENTILATION PER PERSON MIDRISEAPARTMENT APARTMENT OCC TZ_1-A3.B2 18.31 0.5 8.805E-003 4.810E-004 1.699E-002 0.641 Natural 0.000 1.0 1.000 0.000 0.000 0.000 -100.00 100.00 -100.00 -100.00 100.00 40.00
9 TZ_1-A3.LK VENTILATION PER PERSON MIDRISEAPARTMENT APARTMENT OCC TZ_1-A3.LK 86.19 2.4 4.146E-002 4.810E-004 1.699E-002 0.641 Natural 0.000 1.0 1.000 0.000 0.000 0.000 -100.00 100.00 -100.00 -100.00 100.00 40.00
10 TZ_1-A3.W1 VENTILATION PER PERSON MIDRISEAPARTMENT APARTMENT OCC TZ_1-A3.W1 10.81 0.3 5.201E-003 4.810E-004 1.699E-002 0.641 Natural 0.000 1.0 1.000 0.000 0.000 0.000 -100.00 100.00 -100.00 -100.00 100.00 40.00
11 TZ_1-A3.W2 VENTILATION PER PERSON MIDRISEAPARTMENT APARTMENT OCC TZ_1-A3.W2 10.81 0.3 5.201E-003 4.810E-004 1.699E-002 0.641 Natural 0.000 1.0 1.000 0.000 0.000 0.000 -100.00 100.00 -100.00 -100.00 100.00 40.00


AirFlow Model

Simple
1 Simple


RoomAir Model

Zone Name Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined
1 TZ_0-A1.B Mixing/Well-Stirred
2 TZ_0-A1.LK Mixing/Well-Stirred
3 TZ_0-A1.W Mixing/Well-Stirred
4 TZ_0-A2.B Mixing/Well-Stirred
5 TZ_0-A2.LK Mixing/Well-Stirred
6 TZ_0-A2.W Mixing/Well-Stirred
7 TZ_0-H Mixing/Well-Stirred
8 TZ_1-A3.B1 Mixing/Well-Stirred
9 TZ_1-A3.B2 Mixing/Well-Stirred
10 TZ_1-A3.LK Mixing/Well-Stirred
11 TZ_1-A3.W1 Mixing/Well-Stirred
12 TZ_1-A3.W2 Mixing/Well-Stirred
13 TZ_1-H Mixing/Well-Stirred


AirflowNetwork Model:Control

No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation
1 NoMultizoneOrDistribution


Zone Volume Capacitance Multiplier

Sensible Heat Capacity Multiplier Moisture Capacity Multiplier Carbon Dioxide Capacity Multiplier Generic Contaminant Capacity Multiplier
1 1.000 1.000 1.000 1.000


Environment

Environment Name Environment Type Start Date End Date Start DayOfWeek Duration {#days} Source:Start DayOfWeek Use Daylight Saving Use Holidays Apply Weekend Holiday Rule Use Rain Values Use Snow Values Sky Temperature Model
1 RUN PERIOD 1 WeatherFileRunPeriod 01/01/2006 12/31/2006 Sunday 365 Use RunPeriod Specified Day No No No Yes Yes Clark and Allen


Environment:Daylight Saving

Daylight Saving Indicator Source Start Date End Date
1 No RunPeriod Object    


Environment:WarmupDays

NumberofWarmupDays
1 3


Tabular Report

Style Unit Conversion
1 HTML None


Warmup Convergence Information

Zone Name Environment Type/Name Average Warmup Temperature Difference {deltaC} Std Dev Warmup Temperature Difference {deltaC} Max Temperature Pass/Fail Convergence Min Temperature Pass/Fail Convergence Average Warmup Load Difference {W} Std Dev Warmup Load Difference {W} Heating Load Pass/Fail Convergence Cooling Load Pass/Fail Convergence
1 TZ_0-A1.B RunPeriod: RUN PERIOD 1 2.4671622769E-015 2.3038593314E-015 Pass Pass 9.3256524140E-003 1.1639398930E-002 Pass Pass
2 TZ_0-A1.LK RunPeriod: RUN PERIOD 1 2.1957744265E-015 2.2153688555E-015 Pass Pass 1.2292895773E-002 1.9691712731E-002 Pass Pass
3 TZ_0-A1.W RunPeriod: RUN PERIOD 1 2.4918338997E-015 2.1381914915E-015 Pass Pass 1.1016289456E-002 1.5942180206E-002 Pass Pass
4 TZ_0-A2.B RunPeriod: RUN PERIOD 1 3.0839528462E-015 2.3775816422E-015 Pass Pass 1.2324202153E-002 1.3191382588E-002 Pass Pass
5 TZ_0-A2.LK RunPeriod: RUN PERIOD 1 2.7385501274E-015 2.7043294872E-015 Pass Pass 1.3538925531E-002 1.6126911657E-002 Pass Pass
6 TZ_0-A2.W RunPeriod: RUN PERIOD 1 2.5165055225E-015 2.4368770162E-015 Pass Pass 1.1849928890E-002 1.6113985281E-002 Pass Pass
7 TZ_0-H RunPeriod: RUN PERIOD 1 4.6649055635E-002 3.8469743304E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
8 TZ_1-A3.B1 RunPeriod: RUN PERIOD 1 2.6151920136E-015 2.4408702627E-015 Pass Pass 1.0835408551E-002 1.1619431411E-002 Pass Pass
9 TZ_1-A3.B2 RunPeriod: RUN PERIOD 1 2.6645352591E-015 2.4592546852E-015 Pass Pass 1.4474684870E-002 1.4944859816E-002 Pass Pass
10 TZ_1-A3.LK RunPeriod: RUN PERIOD 1 1.9737298216E-015 2.0841315914E-015 Pass Pass 1.5729701182E-002 1.7034593825E-002 Pass Pass
11 TZ_1-A3.W1 RunPeriod: RUN PERIOD 1 2.7632217502E-015 2.3848668173E-015 Pass Pass 1.3149491815E-002 1.5186955181E-002 Pass Pass
12 TZ_1-A3.W2 RunPeriod: RUN PERIOD 1 2.9605947323E-015 2.4770112673E-015 Pass Pass 1.4123446494E-002 1.5655607723E-002 Pass Pass
13 TZ_1-H RunPeriod: RUN PERIOD 1 5.0526935180E-002 4.0963744290E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass



Table of Contents

Report: Annual Heat Emissions Report

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Annual Heat Emissions Summary

Envelope Convection Zone Exfiltration Zone Exhaust Air HVAC Relief Air HVAC Reject Heat Total
Heat Emissions [GJ] 353.99 155.29 0.00 0.00 0.00 509.28



Table of Contents

Report: Annual Thermal Resilience Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Heat Index Hours

Safe (≤ 26.7°C) [hr] Caution (> 26.7°C, ≤ 32.2°C) [hr] Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] Danger (> 39.4°C, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
TZ_0-A1.B 8755.67 4.33 0.00 0.00 0.00
TZ_0-A1.LK 8757.67 2.33 0.00 0.00 0.00
TZ_0-A1.W 8757.00 3.00 0.00 0.00 0.00
TZ_0-A2.B 8756.83 3.17 0.00 0.00 0.00
TZ_0-A2.LK 8758.83 1.17 0.00 0.00 0.00
TZ_0-A2.W 8755.33 4.67 0.00 0.00 0.00
TZ_0-H 8235.83 513.83 10.33 0.00 0.00
TZ_1-A3.B1 8760.00 0.00 0.00 0.00 0.00
TZ_1-A3.B2 8760.00 0.00 0.00 0.00 0.00
TZ_1-A3.LK 8760.00 0.00 0.00 0.00 0.00
TZ_1-A3.W1 8760.00 0.00 0.00 0.00 0.00
TZ_1-A3.W2 8760.00 0.00 0.00 0.00 0.00
TZ_1-H 7565.17 1034.33 160.50 0.00 0.00
Min 7565.17 0.00 0.00 0.00 0.00
Max 8760.00 1034.33 160.50 0.00 0.00
Average 8626.33 120.53 13.14 0.00 0.00
Sum 112142.33 1566.83 170.83 0.00 0.00


Heat Index OccupantHours

Safe (≤ 26.7°C) [hr] Caution (> 26.7°C, ≤ 32.2°C) [hr] Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] Danger (> 39.4°C, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
TZ_0-A1.B 3259.42 1.12 0.00 0.00 0.00
TZ_0-A1.LK 6324.86 1.94 0.00 0.00 0.00
TZ_0-A1.W 1834.03 0.47 0.00 0.00 0.00
TZ_0-A2.B 3105.29 0.85 0.00 0.00 0.00
TZ_0-A2.LK 8295.63 0.98 0.00 0.00 0.00
TZ_0-A2.W 1833.83 0.68 0.00 0.00 0.00
TZ_0-H 0.00 0.00 0.00 0.00 0.00
TZ_1-A3.B1 3260.53 0.00 0.00 0.00 0.00
TZ_1-A3.B2 3106.14 0.00 0.00 0.00 0.00
TZ_1-A3.LK 14623.41 0.00 0.00 0.00 0.00
TZ_1-A3.W1 1834.50 0.00 0.00 0.00 0.00
TZ_1-A3.W2 1834.50 0.00 0.00 0.00 0.00
TZ_1-H 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 14623.41 1.94 0.00 0.00 0.00
Average 3793.24 0.46 0.00 0.00 0.00
Sum 49312.14 6.03 0.00 0.00 0.00


Heat Index OccupiedHours

Safe (≤ 26.7°C) [hr] Caution (> 26.7°C, ≤ 32.2°C) [hr] Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] Danger (> 39.4°C, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
TZ_0-A1.B 8755.67 4.33 0.00 0.00 0.00
TZ_0-A1.LK 8757.67 2.33 0.00 0.00 0.00
TZ_0-A1.W 8757.00 3.00 0.00 0.00 0.00
TZ_0-A2.B 8756.83 3.17 0.00 0.00 0.00
TZ_0-A2.LK 8758.83 1.17 0.00 0.00 0.00
TZ_0-A2.W 8755.33 4.67 0.00 0.00 0.00
TZ_0-H 0.00 0.00 0.00 0.00 0.00
TZ_1-A3.B1 8760.00 0.00 0.00 0.00 0.00
TZ_1-A3.B2 8760.00 0.00 0.00 0.00 0.00
TZ_1-A3.LK 8760.00 0.00 0.00 0.00 0.00
TZ_1-A3.W1 8760.00 0.00 0.00 0.00 0.00
TZ_1-A3.W2 8760.00 0.00 0.00 0.00 0.00
TZ_1-H 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 8760.00 4.67 0.00 0.00 0.00
Average 7410.87 1.44 0.00 0.00 0.00
Sum 96341.33 18.67 0.00 0.00 0.00


Humidex Hours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
TZ_0-A1.B 7930.00 830.00 0.00 0.00 0.00
TZ_0-A1.LK 7828.50 931.50 0.00 0.00 0.00
TZ_0-A1.W 7861.17 898.83 0.00 0.00 0.00
TZ_0-A2.B 7824.67 935.33 0.00 0.00 0.00
TZ_0-A2.LK 7796.00 964.00 0.00 0.00 0.00
TZ_0-A2.W 7823.83 936.17 0.00 0.00 0.00
TZ_0-H 7514.33 1244.67 1.00 0.00 0.00
TZ_1-A3.B1 7682.83 1077.17 0.00 0.00 0.00
TZ_1-A3.B2 7702.17 1057.83 0.00 0.00 0.00
TZ_1-A3.LK 7643.67 1116.33 0.00 0.00 0.00
TZ_1-A3.W1 7644.00 1116.00 0.00 0.00 0.00
TZ_1-A3.W2 7653.67 1106.33 0.00 0.00 0.00
TZ_1-H 7041.33 1677.33 41.33 0.00 0.00
Min 7041.33 830.00 0.00 0.00 0.00
Max 7930.00 1677.33 41.33 0.00 0.00
Average 7688.17 1068.58 3.26 0.00 0.00
Sum 99946.17 13891.50 42.33 0.00 0.00


Humidex OccupantHours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
TZ_0-A1.B 2978.23 282.31 0.00 0.00 0.00
TZ_0-A1.LK 5666.55 660.25 0.00 0.00 0.00
TZ_0-A1.W 1660.48 174.03 0.00 0.00 0.00
TZ_0-A2.B 2812.10 294.04 0.00 0.00 0.00
TZ_0-A2.LK 7455.36 841.25 0.00 0.00 0.00
TZ_0-A2.W 1653.94 180.56 0.00 0.00 0.00
TZ_0-H 0.00 0.00 0.00 0.00 0.00
TZ_1-A3.B1 2897.65 362.89 0.00 0.00 0.00
TZ_1-A3.B2 2759.55 346.59 0.00 0.00 0.00
TZ_1-A3.LK 12859.06 1764.36 0.00 0.00 0.00
TZ_1-A3.W1 1608.34 226.16 0.00 0.00 0.00
TZ_1-A3.W2 1608.16 226.35 0.00 0.00 0.00
TZ_1-H 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 12859.06 1764.36 0.00 0.00 0.00
Average 3381.49 412.21 0.00 0.00 0.00
Sum 43959.40 5358.77 0.00 0.00 0.00


Humidex OccupiedHours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
TZ_0-A1.B 7930.00 830.00 0.00 0.00 0.00
TZ_0-A1.LK 7828.50 931.50 0.00 0.00 0.00
TZ_0-A1.W 7861.17 898.83 0.00 0.00 0.00
TZ_0-A2.B 7824.67 935.33 0.00 0.00 0.00
TZ_0-A2.LK 7796.00 964.00 0.00 0.00 0.00
TZ_0-A2.W 7823.83 936.17 0.00 0.00 0.00
TZ_0-H 0.00 0.00 0.00 0.00 0.00
TZ_1-A3.B1 7682.83 1077.17 0.00 0.00 0.00
TZ_1-A3.B2 7702.17 1057.83 0.00 0.00 0.00
TZ_1-A3.LK 7643.67 1116.33 0.00 0.00 0.00
TZ_1-A3.W1 7644.00 1116.00 0.00 0.00 0.00
TZ_1-A3.W2 7653.67 1106.33 0.00 0.00 0.00
TZ_1-H 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 7930.00 1116.33 0.00 0.00 0.00
Average 6568.50 843.81 0.00 0.00 0.00
Sum 85390.50 10969.50 0.00 0.00 0.00


Hours of Safety for Cold Events

Hours of Safety [hr] End Time of the Safety Duration Safe Temperature Exceedance Hours [hr] Safe Temperature Exceedance OccupantHours [hr] Safe Temperature Exceedance OccupiedHours [hr]
TZ_0-A1.B 8760.00 - 0.00 0.00 0.00
TZ_0-A1.LK 8760.00 - 0.00 0.00 0.00
TZ_0-A1.W 8760.00 - 0.00 0.00 0.00
TZ_0-A2.B 8760.00 - 0.00 0.00 0.00
TZ_0-A2.LK 8760.00 - 0.00 0.00 0.00
TZ_0-A2.W 8760.00 - 0.00 0.00 0.00
TZ_0-H 0.00 - 0.00 0.00 0.00
TZ_1-A3.B1 8760.00 - 0.00 0.00 0.00
TZ_1-A3.B2 8760.00 - 0.00 0.00 0.00
TZ_1-A3.LK 8760.00 - 0.00 0.00 0.00
TZ_1-A3.W1 8760.00 - 0.00 0.00 0.00
TZ_1-A3.W2 8760.00 - 0.00 0.00 0.00
TZ_1-H 0.00 - 0.00 0.00 0.00
Min 0.00 - 0.00 0.00 0.00
Max 8760.00 - 0.00 0.00 0.00
Average 7412.31 - 0.00 0.00 0.00
Sum 96360.00 - 0.00 0.00 0.00


Hours of Safety for Heat Events

Hours of Safety [hr] End Time of the Safety Duration Safe Temperature Exceedance Hours [hr] Safe Temperature Exceedance OccupantHours [hr] Safe Temperature Exceedance OccupiedHours [hr]
TZ_0-A1.B 8760.00 - 0.00 0.00 0.00
TZ_0-A1.LK 8760.00 - 0.00 0.00 0.00
TZ_0-A1.W 8760.00 - 0.00 0.00 0.00
TZ_0-A2.B 8760.00 - 0.00 0.00 0.00
TZ_0-A2.LK 8760.00 - 0.00 0.00 0.00
TZ_0-A2.W 8760.00 - 0.00 0.00 0.00
TZ_0-H 0.00 - 0.00 0.00 0.00
TZ_1-A3.B1 8760.00 - 0.00 0.00 0.00
TZ_1-A3.B2 8760.00 - 0.00 0.00 0.00
TZ_1-A3.LK 8760.00 - 0.00 0.00 0.00
TZ_1-A3.W1 8760.00 - 0.00 0.00 0.00
TZ_1-A3.W2 8760.00 - 0.00 0.00 0.00
TZ_1-H 0.00 - 0.00 0.00 0.00
Min 0.00 - 0.00 0.00 0.00
Max 8760.00 - 0.00 0.00 0.00
Average 7412.31 - 0.00 0.00 0.00
Sum 96360.00 - 0.00 0.00 0.00


Unmet Degree-Hours

Cooling Setpoint Unmet Degree-Hours [°C·hr] Cooling Setpoint Unmet Occupant-Weighted Degree-Hours [°C·hr] Cooling Setpoint Unmet Occupied Degree-Hours [°C·hr] Heating Setpoint Unmet Degree-Hours [°C·hr] Heating Setpoint Unmet Occupant-Weighted Degree-Hours [°C·hr] Heating Setpoint Unmet Occupied Degree-Hours [°C·hr]
TZ_0-A1.B 0.00 0.00 0.00 0.00 0.00 0.00
TZ_0-A1.LK 0.00 0.00 0.00 0.00 0.00 0.00
TZ_0-A1.W 0.00 0.00 0.00 0.00 0.00 0.00
TZ_0-A2.B 0.00 0.00 0.00 0.00 0.00 0.00
TZ_0-A2.LK 0.00 0.00 0.00 0.00 0.00 0.00
TZ_0-A2.W 0.00 0.00 0.00 0.00 0.00 0.00
TZ_0-H 0.00 0.00 0.00 0.00 0.00 0.00
TZ_1-A3.B1 0.00 0.00 0.00 0.00 0.00 0.00
TZ_1-A3.B2 0.00 0.00 0.00 0.00 0.00 0.00
TZ_1-A3.LK 0.00 0.00 0.00 0.00 0.00 0.00
TZ_1-A3.W1 0.00 0.00 0.00 0.00 0.00 0.00
TZ_1-A3.W2 0.00 0.00 0.00 0.00 0.00 0.00
TZ_1-H 0.00 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00 0.00
Max 0.00 0.00 0.00 0.00 0.00 0.00
Average 0.00 0.00 0.00 0.00 0.00 0.00
Sum 0.00 0.00 0.00 0.00 0.00 0.00


Discomfort-weighted Exceedance OccupantHours

Very-cold Exceedance OccupantHours [hr] Cool Exceedance OccupantHours [hr] Warm Exceedance OccupantHours [hr] Very-hot Exceedance OccupantHours [hr]
TZ_0-A1.B 0.00 0.00 0.00 0.00
TZ_0-A1.LK 0.00 0.00 0.00 0.00
TZ_0-A1.W 0.00 0.00 0.00 0.00
TZ_0-A2.B 0.00 0.00 0.00 0.00
TZ_0-A2.LK 0.00 0.00 0.00 0.00
TZ_0-A2.W 0.00 0.00 0.00 0.00
TZ_0-H 0.00 0.00 0.00 0.00
TZ_1-A3.B1 0.00 0.00 0.00 0.00
TZ_1-A3.B2 0.00 0.00 0.00 0.00
TZ_1-A3.LK 0.00 0.00 0.00 0.00
TZ_1-A3.W1 0.00 0.00 0.00 0.00
TZ_1-A3.W2 0.00 0.00 0.00 0.00
TZ_1-H 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 0.00 0.00 0.00
Average 0.00 0.00 0.00 0.00
Sum 0.00 0.00 0.00 0.00


Discomfort-weighted Exceedance OccupiedHours

Very-cold Exceedance OccupantHours [hr] Cool Exceedance OccupantHours [hr] Warm Exceedance OccupantHours [hr] Very-hot Exceedance OccupantHours [hr]
TZ_0-A1.B 0.00 0.00 0.00 0.00
TZ_0-A1.LK 0.00 0.00 0.00 0.00
TZ_0-A1.W 0.00 0.00 0.00 0.00
TZ_0-A2.B 0.00 0.00 0.00 0.00
TZ_0-A2.LK 0.00 0.00 0.00 0.00
TZ_0-A2.W 0.00 0.00 0.00 0.00
TZ_0-H 0.00 0.00 0.00 0.00
TZ_1-A3.B1 0.00 0.00 0.00 0.00
TZ_1-A3.B2 0.00 0.00 0.00 0.00
TZ_1-A3.LK 0.00 0.00 0.00 0.00
TZ_1-A3.W1 0.00 0.00 0.00 0.00
TZ_1-A3.W2 0.00 0.00 0.00 0.00
TZ_1-H 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 0.00 0.00 0.00
Average 0.00 0.00 0.00 0.00
Sum 0.00 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
None            


Monthly Precipitation Summary

Monthly Total Precipitation from .epw [mm] Monthly Total Hours of Rain from .epw Monthly Total Precipitation in Site:Precipitation [mm] Monthly Total Roof Irrigation Depth [mm] Monthly Total Rain Collection Volume [m3]
Jan 70.00 68      
Feb 44.00 44      
Mar 52.00 47      
Apr 102.00 95      
May 96.00 90      
Jun 46.00 46      
Jul 24.00 24      
Aug 42.00 42      
Sep 12.00 12      
Oct 60.00 58      
Nov 98.00 89      
Dec 14.00 14      


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
FACE 23 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 12.29 10.05 0.00 90.00 N
FACE 25 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 10.39 10.39 90.00 90.00 E
FACE 20 TYPICAL INSULATED CARPETED 6IN SLAB FLOOR 0.30 2.250 3.540 19.22 19.22 180.00 180.00  
FACE 18 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 15.25 11.89 0.00 90.00 N
FACE 10 TYPICAL INSULATED CARPETED 6IN SLAB FLOOR 0.30 2.250 3.540 37.29 37.29 270.00 180.00  
FACE 39 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 7.43 6.31 90.00 90.00 E
FACE 30 TYPICAL INSULATED CARPETED 6IN SLAB FLOOR 0.30 2.250 3.540 10.81 10.81 90.00 180.00  
FACE 76 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 9.86 9.86 90.00 90.00 E
FACE 77 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 12.29 10.05 180.00 90.00 S
FACE 68 TYPICAL INSULATED CARPETED 6IN SLAB FLOOR 0.30 2.250 3.540 18.31 18.31 90.00 180.00  
FACE 44 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 12.29 10.04 270.00 90.00 W
FACE 54 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 22.82 19.46 180.00 90.00 S
FACE 42 TYPICAL INSULATED CARPETED 6IN SLAB FLOOR 0.30 2.250 3.540 48.90 48.90 180.00 180.00  
FACE 65 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 7.43 6.31 90.00 90.00 E
FACE 56 TYPICAL INSULATED CARPETED 6IN SLAB FLOOR 0.30 2.250 3.540 10.81 10.81 0.00 180.00  
FACE 7 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 22.82 17.06 270.00 90.00 W
FACE 9 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 7.56 7.56 0.00 90.00 N
FACE 0 TYPICAL INSULATED CARPETED 6IN SLAB FLOOR 0.30 2.250 3.540 23.66 23.66 270.00 180.00  
FACE 110 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 12.29 10.05 0.00 90.00 N
FACE 112 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 10.39 10.39 90.00 90.00 E
FACE 107 TYPICAL IEAD ROOF R-17.24 10 0.30 0.329 0.345 19.22 19.22 180.00 0.00  
FACE 149 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 9.86 9.86 90.00 90.00 E
FACE 150 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 12.29 10.05 180.00 90.00 S
FACE 142 TYPICAL IEAD ROOF R-17.24 10 0.30 0.329 0.345 18.31 18.31 0.00 0.00  
FACE 104 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 22.82 19.46 180.00 90.00 S
FACE 89 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 12.29 10.05 270.00 90.00 W
FACE 94 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 15.25 11.89 0.00 90.00 N
FACE 88 TYPICAL IEAD ROOF R-17.24 10 0.30 0.329 0.345 86.19 86.19 90.00 0.00  
FACE 126 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 7.43 6.31 90.00 90.00 E
FACE 118 TYPICAL IEAD ROOF R-17.24 10 0.30 0.329 0.345 10.81 10.81 0.00 0.00  
FACE 138 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 7.43 6.31 90.00 90.00 E
FACE 130 TYPICAL IEAD ROOF R-17.24 10 0.30 0.329 0.345 10.81 10.81 0.00 0.00  
FACE 84 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 22.82 20.58 270.00 90.00 W
FACE 86 TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.24 4 0.30 0.505 0.547 7.56 7.56 0.00 90.00 N
FACE 80 TYPICAL IEAD ROOF R-17.24 10 0.30 0.329 0.345 23.66 23.66 180.00 0.00  


Opaque Interior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
FACE 22 TYPICAL INTERIOR WALL 0.30 2.511 6.300 13.10 13.10 270.00 90.00 W
FACE 26 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 180.00 90.00 S
FACE 27 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 90.00 90.00 E
FACE 28 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 2.91 180.00 90.00 S
FACE 21 TYPICAL INTERIOR CEILING 0.30 1.887 3.839 19.22 19.22 180.00 0.00  
FACE 12 TYPICAL INTERIOR WALL 0.30 2.511 6.300 13.10 13.10 90.00 90.00 E
FACE 13 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.73 3.05 90.00 90.00 E
FACE 15 TYPICAL INTERIOR WALL 0.30 2.511 6.300 15.25 15.25 180.00 90.00 S
FACE 16 TYPICAL INTERIOR WALL 0.30 2.511 6.300 17.82 15.93 270.00 90.00 W
FACE 11 TYPICAL INTERIOR CEILING 0.30 1.887 3.839 37.29 37.29 0.00 0.00  
FACE 32 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 4.59 180.00 90.00 S
FACE 33 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.73 3.05 270.00 90.00 W
FACE 35 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 2.91 0.00 90.00 N
FACE 37 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 270.00 90.00 W
FACE 38 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 0.00 90.00 N
FACE 41 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 180.00 90.00 S
FACE 31 TYPICAL INTERIOR CEILING 0.30 1.887 3.839 10.81 10.81 0.00 0.00  
FACE 70 TYPICAL INTERIOR WALL 0.30 2.511 6.300 9.86 9.86 270.00 90.00 W
FACE 71 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 270.00 90.00 W
FACE 72 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 2.91 0.00 90.00 N
FACE 74 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 90.00 90.00 E
FACE 75 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 0.00 90.00 N
FACE 69 TYPICAL INTERIOR CEILING 0.30 1.887 3.839 18.31 18.31 0.00 0.00  
FACE 46 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.56 7.56 0.00 90.00 N
FACE 47 TYPICAL INTERIOR WALL 0.30 2.511 6.300 5.00 3.11 270.00 90.00 W
FACE 49 TYPICAL INTERIOR WALL 0.30 2.511 6.300 15.25 15.25 0.00 90.00 N
FACE 50 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.73 3.05 90.00 90.00 E
FACE 52 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 90.00 90.00 E
FACE 53 TYPICAL INTERIOR WALL 0.30 2.511 6.300 9.86 9.86 90.00 90.00 E
FACE 43 TYPICAL INTERIOR CEILING 0.30 1.887 3.839 48.90 48.90 0.00 0.00  
FACE 58 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 270.00 90.00 W
FACE 59 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 2.91 180.00 90.00 S
FACE 61 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.73 3.05 270.00 90.00 W
FACE 63 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 4.59 0.00 90.00 N
FACE 64 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 0.00 90.00 N
FACE 67 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 180.00 90.00 S
FACE 57 TYPICAL INTERIOR CEILING 0.30 1.887 3.839 10.81 10.81 0.00 0.00  
FACE 2 TYPICAL INTERIOR WALL 0.30 2.511 6.300 17.82 15.93 90.00 90.00 E
FACE 4 TYPICAL INTERIOR WALL 0.30 2.511 6.300 5.00 3.11 90.00 90.00 E
FACE 6 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.56 7.56 180.00 90.00 S
FACE 1 TYPICAL INTERIOR CEILING 0.30 1.887 3.839 23.66 23.66 0.00 0.00  
FACE 108 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 270.00 90.00 W
FACE 109 TYPICAL INTERIOR WALL 0.30 2.511 6.300 10.39 10.39 270.00 90.00 W
FACE 113 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 180.00 90.00 S
FACE 114 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 90.00 90.00 E
FACE 115 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 2.91 180.00 90.00 S
FACE 106 TYPICAL INTERIOR FLOOR 0.30 1.887 3.839 19.22 19.22 0.00 180.00  
FACE 143 TYPICAL INTERIOR WALL 0.30 2.511 6.300 9.86 9.86 270.00 90.00 W
FACE 144 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 270.00 90.00 W
FACE 145 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 2.91 0.00 90.00 N
FACE 147 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 90.00 90.00 E
FACE 148 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 0.00 90.00 N
FACE 141 TYPICAL INTERIOR FLOOR 0.30 1.887 3.839 18.31 18.31 180.00 180.00  
FACE 100 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.73 3.05 90.00 90.00 E
FACE 102 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 90.00 90.00 E
FACE 103 TYPICAL INTERIOR WALL 0.30 2.511 6.300 9.86 9.86 90.00 90.00 E
FACE 91 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.56 7.56 0.00 90.00 N
FACE 92 TYPICAL INTERIOR WALL 0.30 2.511 6.300 22.82 20.93 270.00 90.00 W
FACE 96 TYPICAL INTERIOR WALL 0.30 2.511 6.300 10.39 10.39 90.00 90.00 E
FACE 97 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 90.00 90.00 E
FACE 98 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.73 3.05 90.00 90.00 E
FACE 87 TYPICAL INTERIOR FLOOR 0.30 1.887 3.839 37.29 37.29 0.00 180.00  
SURFACE 1 TYPICAL INTERIOR FLOOR 0.30 1.887 3.839 48.90 48.90 0.00 180.00  
FACE 119 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 4.59 180.00 90.00 S
FACE 120 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.73 3.05 270.00 90.00 W
FACE 122 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 2.91 0.00 90.00 N
FACE 124 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 270.00 90.00 W
FACE 125 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 0.00 90.00 N
FACE 128 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 180.00 90.00 S
FACE 117 TYPICAL INTERIOR FLOOR 0.30 1.887 3.839 10.81 10.81 0.00 180.00  
FACE 131 TYPICAL INTERIOR WALL 0.30 2.511 6.300 2.70 2.70 270.00 90.00 W
FACE 132 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 2.91 180.00 90.00 S
FACE 134 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.73 3.05 270.00 90.00 W
FACE 136 TYPICAL INTERIOR WALL 0.30 2.511 6.300 4.59 4.59 0.00 90.00 N
FACE 137 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 0.00 90.00 N
FACE 140 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.69 7.69 180.00 90.00 S
FACE 129 TYPICAL INTERIOR FLOOR 0.30 1.887 3.839 10.81 10.81 0.00 180.00  
FACE 81 TYPICAL INTERIOR WALL 0.30 2.511 6.300 22.82 20.93 90.00 90.00 E
FACE 83 TYPICAL INTERIOR WALL 0.30 2.511 6.300 7.56 7.56 180.00 90.00 S
FACE 79 TYPICAL INTERIOR FLOOR 0.30 1.887 3.839 23.66 23.66 0.00 180.00  


Exterior Fenestration

Construction Frame and Divider Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
FACE 24 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   2.24 0.00 0.00 2.24 2.24 3.354 0.361 0.271             No FACE 23 0.00 90.00 N
FACE 19 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   3.36 0.00 0.00 3.36 3.36 3.354 0.361 0.271             No FACE 18 0.00 90.00 N
FACE 40 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   1.12 0.00 0.00 1.12 1.12 3.354 0.361 0.271             No FACE 39 90.00 90.00 E
FACE 78 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   2.24 0.00 0.00 2.24 2.24 3.354 0.361 0.271             No FACE 77 180.00 90.00 S
FACE 45 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   2.24 0.00 0.00 2.24 2.24 3.354 0.361 0.271             No FACE 44 270.00 90.00 W
FACE 55 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   3.36 0.00 0.00 3.36 3.36 3.354 0.361 0.271             No FACE 54 180.00 90.00 S
FACE 66 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   1.12 0.00 0.00 1.12 1.12 3.354 0.361 0.271             No FACE 65 90.00 90.00 E
FACE 8 U 0.88 SHGC 0.16 SGL REF-A-L CLR 6MM   5.76 0.00 0.00 5.76 5.76 4.440 0.202 0.080             No FACE 7 270.00 90.00 W
FACE 111 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   2.24 0.00 0.00 2.24 2.24 3.354 0.361 0.271             No FACE 110 0.00 90.00 N
FACE 151 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   2.24 0.00 0.00 2.24 2.24 3.354 0.361 0.271             No FACE 150 180.00 90.00 S
FACE 105 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   3.36 0.00 0.00 3.36 3.36 3.354 0.361 0.271             No FACE 104 180.00 90.00 S
FACE 90 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   2.24 0.00 0.00 2.24 2.24 3.354 0.361 0.271             No FACE 89 270.00 90.00 W
FACE 95 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   3.36 0.00 0.00 3.36 3.36 3.354 0.361 0.271             No FACE 94 0.00 90.00 N
FACE 127 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   1.12 0.00 0.00 1.12 1.12 3.354 0.361 0.271             No FACE 126 90.00 90.00 E
FACE 139 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   1.12 0.00 0.00 1.12 1.12 3.354 0.361 0.271             No FACE 138 90.00 90.00 E
FACE 85 U 0.59 SHGC 0.36 SIMPLE GLAZING WINDOW U-0.59 SHGC 0.36 23   2.24 0.00 0.00 2.24 2.24 3.354 0.361 0.271             No FACE 84 270.00 90.00 W
Total or Average             39.36 3.513 0.338 0.243                      
North Total or Average             11.20 3.354 0.361 0.271                      
Non-North Total or Average             28.16 3.577 0.329 0.232                      


Exterior Fenestration Shaded State

Frame and Divider Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance
None                


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          


Interior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
FACE 29 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 28
FACE 14 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 13
FACE 17 TYPICAL INTERIOR DOOR 2.446 5.906 1.89 FACE 16
FACE 34 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 33
FACE 36 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 35
FACE 73 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 72
FACE 48 TYPICAL INTERIOR DOOR 2.446 5.906 1.89 FACE 47
FACE 51 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 50
FACE 60 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 59
FACE 62 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 61
FACE 3 TYPICAL INTERIOR DOOR 2.446 5.906 1.89 FACE 2
FACE 5 TYPICAL INTERIOR DOOR 2.446 5.906 1.89 FACE 4
FACE 116 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 115
FACE 146 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 145
FACE 101 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 100
FACE 93 TYPICAL INTERIOR DOOR 2.446 5.906 1.89 FACE 92
FACE 99 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 98
FACE 121 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 120
FACE 123 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 122
FACE 133 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 132
FACE 135 TYPICAL INTERIOR DOOR 2.446 5.906 1.68 FACE 134
FACE 82 TYPICAL INTERIOR DOOR 2.446 5.906 1.89 FACE 81



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
FACE 24 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
FACE 19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
FACE 40 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
FACE 78 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
FACE 45 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
FACE 55 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
FACE 66 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
FACE 8 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
FACE 111 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
FACE 151 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
FACE 105 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
FACE 90 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
FACE 95 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
FACE 127 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
FACE 139 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
FACE 85 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Interior Lighting

Zone Name Space Name Space Type Lighting Power Density [W/m2] Space Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
1-A3.B1 MIDRISEAPARTMENT APARTMENT LIGHTS TZ_1-A3.B1 1-A3.B1 MIDRISEAPARTMENT APARTMENT 3.8750 19.22 74.47 General MIDRISEAPARTMENT APARTMENT LIGHT 55.16 168.00 55.16 0.0000 Y 0.77
0-A2.B MIDRISEAPARTMENT APARTMENT LIGHTS TZ_0-A2.B 0-A2.B MIDRISEAPARTMENT APARTMENT 3.8750 18.31 70.94 General MIDRISEAPARTMENT APARTMENT LIGHT 55.16 168.00 55.16 0.0000 Y 0.73
0-A1.LK MIDRISEAPARTMENT APARTMENT LIGHTS TZ_0-A1.LK 0-A1.LK MIDRISEAPARTMENT APARTMENT 3.8750 37.29 144.50 General MIDRISEAPARTMENT APARTMENT LIGHT 55.16 168.00 55.16 0.0000 Y 1.50
0-A2.LK MIDRISEAPARTMENT APARTMENT LIGHTS TZ_0-A2.LK 0-A2.LK MIDRISEAPARTMENT APARTMENT 3.8750 48.90 189.49 General MIDRISEAPARTMENT APARTMENT LIGHT 55.16 168.00 55.16 0.0000 Y 1.96
1-A3.W1 MIDRISEAPARTMENT APARTMENT LIGHTS TZ_1-A3.W1 1-A3.W1 MIDRISEAPARTMENT APARTMENT 3.8750 10.81 41.90 General MIDRISEAPARTMENT APARTMENT LIGHT 55.16 168.00 55.16 0.0000 Y 0.43
0-A1.B MIDRISEAPARTMENT APARTMENT LIGHTS TZ_0-A1.B 0-A1.B MIDRISEAPARTMENT APARTMENT 3.8750 19.22 74.47 General MIDRISEAPARTMENT APARTMENT LIGHT 55.16 168.00 55.16 0.0000 Y 0.77
0-A1.W MIDRISEAPARTMENT APARTMENT LIGHTS TZ_0-A1.W 0-A1.W MIDRISEAPARTMENT APARTMENT 3.8750 10.81 41.90 General MIDRISEAPARTMENT APARTMENT LIGHT 55.16 168.00 55.16 0.0000 Y 0.43
0-A2.W MIDRISEAPARTMENT APARTMENT LIGHTS TZ_0-A2.W 0-A2.W MIDRISEAPARTMENT APARTMENT 3.8750 10.81 41.90 General MIDRISEAPARTMENT APARTMENT LIGHT 55.16 168.00 55.16 0.0000 Y 0.43
1-A3.B2 MIDRISEAPARTMENT APARTMENT LIGHTS TZ_1-A3.B2 1-A3.B2 MIDRISEAPARTMENT APARTMENT 3.8750 18.31 70.94 General MIDRISEAPARTMENT APARTMENT LIGHT 55.16 168.00 55.16 0.0000 Y 0.73
1-A3.LK MIDRISEAPARTMENT APARTMENT LIGHTS TZ_1-A3.LK 1-A3.LK MIDRISEAPARTMENT APARTMENT 3.8750 86.19 333.99 General MIDRISEAPARTMENT APARTMENT LIGHT 55.16 168.00 55.16 0.0000 Y 3.46
1-A3.W2 MIDRISEAPARTMENT APARTMENT LIGHTS TZ_1-A3.W2 1-A3.W2 MIDRISEAPARTMENT APARTMENT 3.8750 10.81 41.90 General MIDRISEAPARTMENT APARTMENT LIGHT 55.16 168.00 55.16 0.0000 Y 0.43
0-H MIDRISEAPARTMENT CORRIDOR LIGHTS TZ_0-H 0-H MIDRISEAPARTMENT CORRIDOR 9.9028 23.66 234.30 General MIDRISEAPARTMENT CORRIDOR LIGHT 168.00 168.00 168.00 0.0000 N 7.39
1-H MIDRISEAPARTMENT CORRIDOR LIGHTS TZ_1-H 1-H MIDRISEAPARTMENT CORRIDOR 9.9028 23.66 234.30 General MIDRISEAPARTMENT CORRIDOR LIGHT 168.00 168.00 168.00 0.0000 N 7.39
Interior Lighting Total       4.7189 338.00 1594.99               26.44


Daylighting

Zone Control Name Daylighting Method Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None              


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
Exterior Lighting Total 0.00           0.00



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Central Plant

Type Reference Capacity [W] Reference Efficiency [W/W] Rated Capacity [W] Rated Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None              


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
None                  


DX Cooling Coil Standard Ratings 2017

Cooling Coil Type #1 Standard Rated Net Cooling Capacity [W] #2 Standard Rated Net COP [W/W] #2 EER [Btu/W-h] #2 SEER User [Btu/W-h] #2,3 SEER Standard [Btu/W-h] #2,3 IEER [Btu/W-h] #2
None              


DX Cooling Coil Standard Ratings 2023

Cooling Coil Type #1 Standard Rated Net Cooling Capacity [W] #2 Standard Rated Net COP [W/W] #2,4 EER [Btu/W-h] #2,4 SEER User [Btu/W-h] #2,3 SEER Standard [Btu/W-h] #2,3 IEER [Btu/W-h] #2
None              


DX Cooling Coil ASHRAE 127 Standard Ratings Report

DX Cooling Coil Type Rated Net Cooling Capacity Test A [W] Rated Electric Power Test A [W] Rated Net Cooling Capacity Test B [W] Rated Electric Power Test B [W] Rated Net Cooling Capacity Test C [W] Rated Electric Power Test C [W] Rated Net Cooling Capacity Test D [W] Rated Electric Power Test D [W]
None                  


Water-to-Air Heat Pumps at Rated Temperatures Report

Coil Type Rated Total Capacity [W] Rated Sensible Capacity [W] Rated Power[W] Rated COP [W/W] Rated Air Dry-bulb Temperature [C] Rated Air Wet-bulb Temperature [C] Rated Water Temperature [C] Design Day used for Sizing
None                  


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number Minimum Outdoor Dry-Bulb Temperature for Compressor Operation Airloop Name
None              


DX Heating Coils [ HSPF2 ]

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF2 [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W] Used as Supplementary Heat Airloop Name Plantloop Name
None              


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electricity Rate [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction Fan Energy Index End Use Subcategory Design Day Name for Fan Sizing Peak Date/Time for Fan Sizing Peak Purpose Is Autosized Motor Efficiency Motor Heat to Zone Fraction Airloop Name
None                                


Pumps

Type Control Head [pa] Water Flow [m3/s] Electricity Rate [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W] End Use Subcategory Is Autosized Plantloop Name Plantloop Branch Name
None                      


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
None            


Chillers

Type Reference Capacity[W] TypeReference Efficiency [W/W] Rated Capacity [W] Rated Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h] Minimum Part Load Ratio Fuel Type Rated Entering Condenser Temperature [C] Rated Leaving Evaporator Temperature [C] Reference Entering Condenser Temperature [C] Reference Leaving Evaporator Temperature [C] Design Size Reference Chilled Water Flow Rate [kg/s] Design Size Reference Condenser Fluid Flow Rate [kg/s] Plantloop Name Plantloop Branch Name Condenser Loop Name Condenser Loop Branch Name Heat Recovery Plantloop Name Heat Recovery Plantloop Branch Name Recovery Relative Capacity Fraction
None                                            


Boilers

Type Reference Capacity [W] Reference Efficiency[W/W] Rated Capacity [W] Rated Efficiency [W/W] Minimum Part Load Ratio Fuel Type Parasitic Electric Load [W] Plantloop Name Plantloop Branch Name
None                    


Cooling Towers and Fluid Coolers

Type Fluid Type Range [C] Approach [C] Design Fan Power [W] Design Inlet Air Wet-Bulb Temperature [C] Design Water Flow Rate [m3/s] Leaving Water Setpoint Temperature [C] Condenser Loop Name Condenser Loop Branch Name
None                    


PlantLoop or CondenserLoop

Type Provides Heating Provides Cooling Maximum Loop Flow Rate [m3/s] Minimum Loop Flow Rate [m3/s]
None          


Air Terminals

Zone Name Minimum Flow [m3/s] Minimum Outdoor Flow [m3/s] Supply Cooling Setpoint [C] Supply Heating Setpoint [C] Heating Capacity [W] Cooling Capacity [W]
None              


Air Heat Recovery

Name Input object type Plate/Rotary Sensible Effectiveness at 100% Heating Air Flow Sensible Effectiveness at 100% Cooling Air Flow Latent Effectiveness at 100% Heating Air Flow Latent Effectiveness at 100% Cooling Air Flow Exhaust Airflow [kg/s] Outdoor Airflow [kg/s]
None                  



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Space Sensible Cooling

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
None                            
The Design Load is the space sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Cooling

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
None                            
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

Space Sensible Heating

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
None                            
The Design Load is the space sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Heating

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
None                            
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s] Adjusted cooling [m3/s] Adjusted heating [m3/s] Adjusted main [m3/s] Calculated Heating Air Flow Ratio [] User Heating Air Flow Ratio []
None                  


Plant Loop Coincident Design Fluid Flow Rate Adjustments

Previous Design Volume Flow Rate [m3/s] Algorithm Volume Flow Rate [m3/s] Coincident Design Volume Flow Rate [m3/s] Coincident Size Adjusted Peak Sizing Period Name Peak Day into Period {TIMESTAMP}[day] Peak Hour Of Day {TIMESTAMP}[hr] Peak Step Start Minute {TIMESTAMP}[min]
None                


Coil Sizing Summary

Coil Type HVAC Type HVAC Name Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Flow Percentage at Ideal Loads Peak [%] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W]
None                                                                



Table of Contents

Report: Coil Sizing Details

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Coils

Coil Type Coil Location HVAC Type HVAC Name Zone Name(s) System Sizing Method Concurrence System Sizing Method Capacity System Sizing Method Air Flow Autosized Coil Capacity? Autosized Coil Airflow? Autosized Coil Water Flow? OA Pretreated prior to coil inlet? Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Terminal Unit Reheat Coil Multiplier DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio Moist Air Heat Capacity [J/kg-K] Dry Air Heat Capacity [J/kg-K] Standard Air Density Adjusted for Elevation [kg/m3] Supply Fan Name for Coil Supply Fan Type for Coil Supply Fan Maximum Air Volume Flow Rate [m3/s] Supply Fan Maximum Air Mass Flow Rate [kg/s] Plant Name for Coil Plant Fluid Specific Heat Capacity [J/kg-K] Plant Fluid Density [kg/m3] Plant Maximum Fluid Mass Flow Rate [kg/s] Plant Design Fluid Return Temperature [C] Plant Design Fluid Supply Temperature [C] Plant Design Fluid Temperature Difference [deltaC] Plant Design Capacity [W] Coil Capacity Percentage of Plant Design Capacity [%] Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Total Ideal Loads Peak Date/Time at Total Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Peak Load Type to Size On Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] Supply Fan Air Heat Gain at Ideal Loads Peak [W] Coil and Fan Net Total Capacity at Ideal Loads Peak [W] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] Outdoor Air Flow Percentage at Ideal Loads Peak [%] System Return Air Drybulb at Ideal Loads Peak [C] System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W] Coil Air Mass Flow Rate at Rating Conditions [kg/s] Coil Entering Air Drybulb at Rating Conditions [C] Coil Entering Air Wetbulb at Rating Conditions [C] Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] Coil Leaving Air Drybulb at Rating Conditions [C] Coil Leaving Air Wetbulb at Rating Conditions [C] Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K]
None                                                                                                                                                                            


Coil Connections

Coil Name Coil Type Coil Location HVAC Type HVAC Name Zone Name(s) Supply Fan Name for HVAC Supply Fan Type for HVAC Airloop Name Plant Name for Coil Plant Loop Name
None                      



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Outdoor Air Per Zone [m3/s] Outdoor Air ACH [ach] Outdoor Air Method Outdoor Air Schedule Name Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule Name
None                    


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
TZ_0-A1.B 6936.17 8463.33 6720.67
TZ_0-A1.LK 6858.83 8506.83 6676.83
TZ_0-A1.W 6769.67 8435.50 6547.50
TZ_0-A2.B 6809.67 8201.67 6373.33
TZ_0-A2.LK 6839.50 8272.50 6463.67
TZ_0-A2.W 6724.00 8370.00 6445.67
TZ_1-A3.B1 7268.33 7788.17 6382.83
TZ_1-A3.B2 7161.33 7765.00 6278.50
TZ_1-A3.LK 7242.33 7722.00 6313.50
TZ_1-A3.W1 7162.50 7540.83 6048.50
TZ_1-A3.W2 7142.00 7501.67 5998.50
TZ_0-H 0.00 0.00 0.00
TZ_1-H 0.00 0.00 0.00
Facility 7930.33 8632.83 7123.67
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
TZ_0-A1.B 0.00 0.00 0.00 0.00
TZ_0-A1.LK 0.00 0.00 0.00 0.00
TZ_0-A1.W 0.00 0.00 0.00 0.00
TZ_0-A2.B 0.00 0.00 0.00 0.00
TZ_0-A2.LK 0.00 0.00 0.00 0.00
TZ_0-A2.W 0.00 0.00 0.00 0.00
TZ_1-A3.B1 0.00 0.00 0.00 0.00
TZ_1-A3.B2 0.00 0.00 0.00 0.00
TZ_1-A3.LK 0.00 0.00 0.00 0.00
TZ_1-A3.W1 0.00 0.00 0.00 0.00
TZ_1-A3.W2 0.00 0.00 0.00 0.00
TZ_0-H 0.00 0.00 0.00 0.00
TZ_1-H 0.00 0.00 0.00 0.00
Facility 0.00 0.00 0.00 0.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
TZ_0-A1.B 0.37 0.54 51.89 0.000 1.841 0.000 0.455
TZ_0-A1.LK 0.72 1.06 100.68 0.000 0.639 0.000 0.455
TZ_0-A1.W 0.21 0.31 29.19 0.000 1.072 0.000 0.455
TZ_0-A2.B 0.35 0.52 49.43 0.000 1.888 0.000 0.455
TZ_0-A2.LK 0.95 1.38 132.03 0.000 1.121 0.000 0.455
TZ_0-A2.W 0.21 0.31 29.19 0.000 1.072 0.000 0.455
TZ_1-A3.B1 0.37 0.54 51.89 0.000 1.844 0.000 0.456
TZ_1-A3.B2 0.35 0.52 49.43 0.000 1.890 0.000 0.456
TZ_1-A3.LK 1.67 2.44 232.71 0.000 0.913 0.000 0.456
TZ_1-A3.W1 0.21 0.31 29.19 0.000 1.074 0.000 0.456
TZ_1-A3.W2 0.21 0.31 29.19 0.000 1.074 0.000 0.456
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
TZ_0-A1.B 0.37 0.54 51.89 0.000 0.098 0.000 0.011
TZ_0-A1.LK 0.72 1.06 100.68 0.000 0.034 0.000 0.011
TZ_0-A1.W 0.21 0.31 29.19 0.000 0.057 0.000 0.011
TZ_0-A2.B 0.35 0.52 49.43 0.000 0.101 0.000 0.011
TZ_0-A2.LK 0.95 1.38 132.03 0.000 0.060 0.000 0.011
TZ_0-A2.W 0.21 0.31 29.19 0.000 0.057 0.000 0.011
TZ_1-A3.B1 0.37 0.54 51.89 0.000 0.099 0.000 0.011
TZ_1-A3.B2 0.35 0.52 49.43 0.000 0.102 0.000 0.011
TZ_1-A3.LK 1.67 2.44 232.71 0.000 0.049 0.000 0.011
TZ_1-A3.W1 0.21 0.31 29.19 0.000 0.058 0.000 0.011
TZ_1-A3.W2 0.21 0.31 29.19 0.000 0.058 0.000 0.011
Values shown for a single zone without multipliers


Table of Contents

Report: Outdoor Air Details

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Mechanical Ventilation Parameters by Zone

AirLoop Name Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Zone Area [m2] Design Zone Outdoor Airflow - Voz [m3/s] Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s]
TZ_0-A1.B   0.37 0.54 51.89 19.22   0.000
TZ_0-A1.LK   0.72 1.06 100.68 37.29   0.000
TZ_0-A1.W   0.21 0.31 29.19 10.81   0.000
TZ_0-A2.B   0.35 0.52 49.43 18.31   0.000
TZ_0-A2.LK   0.95 1.38 132.03 48.90   0.000
TZ_0-A2.W   0.21 0.31 29.19 10.81   0.000
TZ_1-A3.B1   0.37 0.54 51.89 19.22   0.000
TZ_1-A3.B2   0.35 0.52 49.43 18.31   0.000
TZ_1-A3.LK   1.67 2.44 232.71 86.19   0.000
TZ_1-A3.W1   0.21 0.31 29.19 10.81   0.000
TZ_1-A3.W2   0.21 0.31 29.19 10.81   0.000
Total Facility   5.63 8.23 784.84 290.68 0.0000 0.000


Total Outdoor Air by Zone

Mechanical Ventilation [m3] Natural Ventilation [m3] Total Ventilation [m3] Infiltration [m3] Total Ventilation and Infiltration [m3] Dynamic Target Ventilation - Voz-dyn [m3] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr] Time Above Zero When Unoccupied [hr]
TZ_0-A1.B 0.00 204463.23 204463.23 826857.22 1031320.44 0.00 0.00 0.00 8760.00 0.00
TZ_0-A1.LK 0.00 396744.30 396744.30 556159.91 952904.22 0.00 0.00 0.00 8760.00 0.00
TZ_0-A1.W 0.00 115038.83 115038.83 270697.30 385736.13 0.00 0.00 0.00 8760.00 0.00
TZ_0-A2.B 0.00 194781.34 194781.34 807170.14 1001951.49 0.00 0.00 0.00 8760.00 0.00
TZ_0-A2.LK 0.00 520268.07 520268.07 1279659.98 1799928.05 0.00 0.00 0.00 8760.00 0.00
TZ_0-A2.W 0.00 115038.83 115038.83 270697.30 385736.13 0.00 0.00 0.00 8760.00 0.00
TZ_1-A3.B1 0.00 204475.90 204475.90 826908.26 1031384.16 0.00 0.00 0.00 8760.00 0.00
TZ_1-A3.B2 0.00 194793.42 194793.42 807219.96 1002013.39 0.00 0.00 0.00 8760.00 0.00
TZ_1-A3.LK 0.00 917069.23 917069.23 1835933.21 2753002.44 0.00 0.00 0.00 8760.00 0.00
TZ_1-A3.W1 0.00 115045.96 115045.96 270714.01 385759.97 0.00 0.00 0.00 8760.00 0.00
TZ_1-A3.W2 0.00 115045.96 115045.96 270714.01 385759.97 0.00 0.00 0.00 8760.00 0.00
Total Facility 0.00 3092765.07 3092765.07 8022731.32 11115496.39 0.00 0.00 0.00 8760.00 0.00


Average Outdoor Air During Occupancy by Zone - Flow Rates

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Infiltration [m3/s] Total Ventilation and Infiltration [m3/s] Dynamic Target Ventilation - Voz-dyn [m3/s] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr]
TZ_0-A1.B 0.0000 0.0065 0.0065 0.0262 0.0327 0.0000 0.00 0.00 8760.00
TZ_0-A1.LK 0.0000 0.0126 0.0126 0.0176 0.0302 0.0000 0.00 0.00 8760.00
TZ_0-A1.W 0.0000 0.0036 0.0036 0.0086 0.0122 0.0000 0.00 0.00 8760.00
TZ_0-A2.B 0.0000 0.0062 0.0062 0.0256 0.0318 0.0000 0.00 0.00 8760.00
TZ_0-A2.LK 0.0000 0.0165 0.0165 0.0406 0.0571 0.0000 0.00 0.00 8760.00
TZ_0-A2.W 0.0000 0.0036 0.0036 0.0086 0.0122 0.0000 0.00 0.00 8760.00
TZ_1-A3.B1 0.0000 0.0065 0.0065 0.0262 0.0327 0.0000 0.00 0.00 8760.00
TZ_1-A3.B2 0.0000 0.0062 0.0062 0.0256 0.0318 0.0000 0.00 0.00 8760.00
TZ_1-A3.LK 0.0000 0.0291 0.0291 0.0582 0.0873 0.0000 0.00 0.00 8760.00
TZ_1-A3.W1 0.0000 0.0036 0.0036 0.0086 0.0122 0.0000 0.00 0.00 8760.00
TZ_1-A3.W2 0.0000 0.0036 0.0036 0.0086 0.0122 0.0000 0.00 0.00 8760.00
Total Facility 0.0000 0.0981 0.0981 0.2544 0.3525 0.0000 0.00 0.00 8760.00


Total Outdoor Air by AirLoop

Mechanical Ventilation [m3] Natural Ventilation [m3] Total Ventilation [m3] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr] Time Above Zero When Unoccupied [hr]
None                


Average Outdoor Air During Occupancy by AirLoop

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr]
None              


Outdoor Air Controller Limiting Factors by AirLoop

No Limiting Factor [hr] Limits and Scheduled Limits [hr] Economizer [hr] Exhaust Flow [hr] Mixed Air Flow [hr] High Humidity [hr] Demand Controlled Ventilation [hr] Night Ventilation [hr] Demand Limiting [hr] Energy Management System [hr]
None                    


Average Outdoor Air for Limiting Factors During Occupancy

No Limiting Factor [m3/s] Limits and Scheduled Limits [m3/s] Economizer [m3/s] Exhaust Flow [m3/s] Mixed Air Flow [m3/s] High Humidity [m3/s] Demand Controlled Ventilation [m3/s] Night Ventilation [m3/s] Demand Limiting [m3/s] Energy Management System [m3/s]
None                    



Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Surfaces by Class

Total Outdoors
Wall 88 22
Floor 14 7
Roof 13 6
Internal Mass 0 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 16 16
Door 22 0
Glass Door 1 1
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 0
Conditioned Zones 11
Unconditioned Zones 2
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 435
Defaulted Fields 659
Fields with Defaults 1355
Autosized Fields 0
Autosizable Fields 44
Autocalculated Fields 385
Autocalculatable Fields 385



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Electricity Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
Electricity:Facility 58.90 1138.55 01-JAN-03:10 3034.14 01-JAN-19:10
Electricity:Building 58.90 1138.55 01-JAN-03:10 3034.14 01-JAN-19:10
Electricity:Zone:TZ_1-A3.B1 2.92 44.29 01-JAN-03:10 169.61 01-JAN-19:10
Electricity:SpaceType:MIDRISEAPARTMENT APARTMENT 44.12 669.95 01-JAN-03:10 2565.53 01-JAN-19:10
InteriorLights:Electricity 26.44 544.07 01-JAN-00:10 1594.99 01-JAN-20:10
InteriorLights:Electricity:Zone:TZ_1-A3.B1 0.77 4.99 01-JAN-00:10 74.47 01-JAN-20:10
InteriorLights:Electricity:SpaceType:MIDRISEAPARTMENT APARTMENT 11.66 75.47 01-JAN-00:10 1126.39 01-JAN-20:10
General:InteriorLights:Electricity 26.44 544.07 01-JAN-00:10 1594.99 01-JAN-20:10
General:InteriorLights:Electricity:Zone:TZ_1-A3.B1 0.77 4.99 01-JAN-00:10 74.47 01-JAN-20:10
General:InteriorLights:Electricity:SpaceType:MIDRISEAPARTMENT APARTMENT 11.66 75.47 01-JAN-00:10 1126.39 01-JAN-20:10
Electricity:Zone:TZ_0-A2.B 2.78 42.19 01-JAN-03:10 161.58 01-JAN-19:10
InteriorLights:Electricity:Zone:TZ_0-A2.B 0.73 4.75 01-JAN-00:10 70.94 01-JAN-20:10
General:InteriorLights:Electricity:Zone:TZ_0-A2.B 0.73 4.75 01-JAN-00:10 70.94 01-JAN-20:10
Electricity:Zone:TZ_0-A1.LK 5.66 85.94 01-JAN-03:10 329.12 01-JAN-19:10
InteriorLights:Electricity:Zone:TZ_0-A1.LK 1.50 9.68 01-JAN-00:10 144.50 01-JAN-20:10
General:InteriorLights:Electricity:Zone:TZ_0-A1.LK 1.50 9.68 01-JAN-00:10 144.50 01-JAN-20:10
Electricity:Zone:TZ_0-A2.LK 7.42 112.70 01-JAN-03:10 431.59 01-JAN-19:10
InteriorLights:Electricity:Zone:TZ_0-A2.LK 1.96 12.70 01-JAN-00:10 189.49 01-JAN-20:10
General:InteriorLights:Electricity:Zone:TZ_0-A2.LK 1.96 12.70 01-JAN-00:10 189.49 01-JAN-20:10
Electricity:Zone:TZ_1-A3.W1 1.64 24.92 01-JAN-03:10 95.43 01-JAN-19:10
InteriorLights:Electricity:Zone:TZ_1-A3.W1 0.43 2.81 01-JAN-00:10 41.90 01-JAN-20:10
General:InteriorLights:Electricity:Zone:TZ_1-A3.W1 0.43 2.81 01-JAN-00:10 41.90 01-JAN-20:10
Electricity:Zone:TZ_0-A1.B 2.92 44.29 01-JAN-03:10 169.61 01-JAN-19:10
InteriorLights:Electricity:Zone:TZ_0-A1.B 0.77 4.99 01-JAN-00:10 74.47 01-JAN-20:10
General:InteriorLights:Electricity:Zone:TZ_0-A1.B 0.77 4.99 01-JAN-00:10 74.47 01-JAN-20:10
Electricity:Zone:TZ_0-A1.W 1.64 24.92 01-JAN-03:10 95.43 01-JAN-19:10
InteriorLights:Electricity:Zone:TZ_0-A1.W 0.43 2.81 01-JAN-00:10 41.90 01-JAN-20:10
General:InteriorLights:Electricity:Zone:TZ_0-A1.W 0.43 2.81 01-JAN-00:10 41.90 01-JAN-20:10
Electricity:Zone:TZ_0-A2.W 1.64 24.92 01-JAN-03:10 95.43 01-JAN-19:10
InteriorLights:Electricity:Zone:TZ_0-A2.W 0.43 2.81 01-JAN-00:10 41.90 01-JAN-20:10
General:InteriorLights:Electricity:Zone:TZ_0-A2.W 0.43 2.81 01-JAN-00:10 41.90 01-JAN-20:10
Electricity:Zone:TZ_1-A3.B2 2.78 42.19 01-JAN-03:10 161.58 01-JAN-19:10
InteriorLights:Electricity:Zone:TZ_1-A3.B2 0.73 4.75 01-JAN-00:10 70.94 01-JAN-20:10
General:InteriorLights:Electricity:Zone:TZ_1-A3.B2 0.73 4.75 01-JAN-00:10 70.94 01-JAN-20:10
Electricity:Zone:TZ_1-A3.LK 13.08 198.65 01-JAN-03:10 760.71 01-JAN-19:10
InteriorLights:Electricity:Zone:TZ_1-A3.LK 3.46 22.38 01-JAN-00:10 333.99 01-JAN-20:10
General:InteriorLights:Electricity:Zone:TZ_1-A3.LK 3.46 22.38 01-JAN-00:10 333.99 01-JAN-20:10
Electricity:Zone:TZ_1-A3.W2 1.64 24.92 01-JAN-03:10 95.43 01-JAN-19:10
InteriorLights:Electricity:Zone:TZ_1-A3.W2 0.43 2.81 01-JAN-00:10 41.90 01-JAN-20:10
General:InteriorLights:Electricity:Zone:TZ_1-A3.W2 0.43 2.81 01-JAN-00:10 41.90 01-JAN-20:10
Electricity:Zone:TZ_0-H 7.39 234.30 01-JAN-00:10 234.30 01-JAN-00:10
Electricity:SpaceType:MIDRISEAPARTMENT CORRIDOR 14.78 468.60 01-JAN-00:10 468.60 01-JAN-00:10
InteriorLights:Electricity:Zone:TZ_0-H 7.39 234.30 01-JAN-00:10 234.30 01-JAN-00:10
InteriorLights:Electricity:SpaceType:MIDRISEAPARTMENT CORRIDOR 14.78 468.60 01-JAN-00:10 468.60 01-JAN-00:10
General:InteriorLights:Electricity:Zone:TZ_0-H 7.39 234.30 01-JAN-00:10 234.30 01-JAN-00:10
General:InteriorLights:Electricity:SpaceType:MIDRISEAPARTMENT CORRIDOR 14.78 468.60 01-JAN-00:10 468.60 01-JAN-00:10
Electricity:Zone:TZ_1-H 7.39 234.30 01-JAN-00:10 234.30 01-JAN-00:10
InteriorLights:Electricity:Zone:TZ_1-H 7.39 234.30 01-JAN-00:10 234.30 01-JAN-00:10
General:InteriorLights:Electricity:Zone:TZ_1-H 7.39 234.30 01-JAN-00:10 234.30 01-JAN-00:10
InteriorEquipment:Electricity 32.46 594.48 01-JAN-03:10 1564.43 01-JAN-17:10
InteriorEquipment:Electricity:Zone:TZ_1-A3.B1 2.15 39.30 01-JAN-03:10 103.43 01-JAN-17:10
InteriorEquipment:Electricity:SpaceType:MIDRISEAPARTMENT APARTMENT 32.46 594.48 01-JAN-03:10 1564.43 01-JAN-17:10
General:InteriorEquipment:Electricity 32.46 594.48 01-JAN-03:10 1564.43 01-JAN-17:10
General:InteriorEquipment:Electricity:Zone:TZ_1-A3.B1 2.15 39.30 01-JAN-03:10 103.43 01-JAN-17:10
General:InteriorEquipment:Electricity:SpaceType:MIDRISEAPARTMENT APARTMENT 32.46 594.48 01-JAN-03:10 1564.43 01-JAN-17:10
InteriorEquipment:Electricity:Zone:TZ_0-A2.B 2.04 37.44 01-JAN-03:10 98.53 01-JAN-17:10
General:InteriorEquipment:Electricity:Zone:TZ_0-A2.B 2.04 37.44 01-JAN-03:10 98.53 01-JAN-17:10
InteriorEquipment:Electricity:Zone:TZ_0-A1.LK 4.16 76.26 01-JAN-03:10 200.69 01-JAN-17:10
General:InteriorEquipment:Electricity:Zone:TZ_0-A1.LK 4.16 76.26 01-JAN-03:10 200.69 01-JAN-17:10
InteriorEquipment:Electricity:Zone:TZ_0-A2.LK 5.46 100.01 01-JAN-03:10 263.18 01-JAN-17:10
General:InteriorEquipment:Electricity:Zone:TZ_0-A2.LK 5.46 100.01 01-JAN-03:10 263.18 01-JAN-17:10
InteriorEquipment:Electricity:Zone:TZ_1-A3.W1 1.21 22.11 01-JAN-03:10 58.19 01-JAN-17:10
General:InteriorEquipment:Electricity:Zone:TZ_1-A3.W1 1.21 22.11 01-JAN-03:10 58.19 01-JAN-17:10
InteriorEquipment:Electricity:Zone:TZ_0-A1.B 2.15 39.30 01-JAN-03:10 103.43 01-JAN-17:10
General:InteriorEquipment:Electricity:Zone:TZ_0-A1.B 2.15 39.30 01-JAN-03:10 103.43 01-JAN-17:10
InteriorEquipment:Electricity:Zone:TZ_0-A1.W 1.21 22.11 01-JAN-03:10 58.19 01-JAN-17:10
General:InteriorEquipment:Electricity:Zone:TZ_0-A1.W 1.21 22.11 01-JAN-03:10 58.19 01-JAN-17:10
InteriorEquipment:Electricity:Zone:TZ_0-A2.W 1.21 22.11 01-JAN-03:10 58.19 01-JAN-17:10
General:InteriorEquipment:Electricity:Zone:TZ_0-A2.W 1.21 22.11 01-JAN-03:10 58.19 01-JAN-17:10
InteriorEquipment:Electricity:Zone:TZ_1-A3.B2 2.04 37.44 01-JAN-03:10 98.53 01-JAN-17:10
General:InteriorEquipment:Electricity:Zone:TZ_1-A3.B2 2.04 37.44 01-JAN-03:10 98.53 01-JAN-17:10
InteriorEquipment:Electricity:Zone:TZ_1-A3.LK 9.62 176.27 01-JAN-03:10 463.87 01-JAN-17:10
General:InteriorEquipment:Electricity:Zone:TZ_1-A3.LK 9.62 176.27 01-JAN-03:10 463.87 01-JAN-17:10
InteriorEquipment:Electricity:Zone:TZ_1-A3.W2 1.21 22.11 01-JAN-03:10 58.19 01-JAN-17:10
General:InteriorEquipment:Electricity:Zone:TZ_1-A3.W2 1.21 22.11 01-JAN-03:10 58.19 01-JAN-17:10
Fans:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:TZ_0-A1.B 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:TZ_0-A1.B 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:TZ_0-A1.LK 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:TZ_0-A1.LK 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:TZ_0-A1.W 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:TZ_0-A1.W 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:TZ_0-A2.B 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:TZ_0-A2.B 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:TZ_0-A2.LK 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:TZ_0-A2.LK 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:TZ_0-A2.W 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:TZ_0-A2.W 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:TZ_1-A3.B1 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:TZ_1-A3.B1 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:TZ_1-A3.B2 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:TZ_1-A3.B2 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:TZ_1-A3.LK 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:TZ_1-A3.LK 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:TZ_1-A3.W1 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:TZ_1-A3.W1 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:TZ_1-A3.W2 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:TZ_1-A3.W2 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricityPurchased:Facility 58.90 1138.55 01-JAN-03:10 3034.14 01-JAN-19:10
ElectricityPurchased:Plant 58.90 1138.55 01-JAN-03:10 3034.14 01-JAN-19:10
Cogeneration:ElectricityPurchased 58.90 1138.55 01-JAN-03:10 3034.14 01-JAN-19:10
General:Cogeneration:ElectricityPurchased 58.90 1138.55 01-JAN-03:10 3034.14 01-JAN-19:10
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricityNet:Facility 58.90 1138.55 01-JAN-03:10 3034.14 01-JAN-19:10
ElectricityNet:Plant 58.90 1138.55 01-JAN-03:10 3034.14 01-JAN-19:10
Cogeneration:ElectricityNet 58.90 1138.55 01-JAN-03:10 3034.14 01-JAN-19:10
General:Cogeneration:ElectricityNet 58.90 1138.55 01-JAN-03:10 3034.14 01-JAN-19:10
Values shown are for all completed run periods - including any simulations run during sizing periods

Annual and Peak Values - Natural Gas

Natural Gas Annual Value [GJ] Natural Gas Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Natural Gas Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
None          
Values shown are for all completed run periods - including any simulations run during sizing periods

Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Cooling Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
DistrictCooling:Facility 9.80 0.00 01-JAN-00:10 9110.11 21-JUL-18:10
DistrictCooling:HVAC 9.80 0.00 01-JAN-00:10 9110.11 21-JUL-18:10
Cooling:DistrictCooling 9.80 0.00 01-JAN-00:10 9110.11 21-JUL-18:10
General:Cooling:DistrictCooling 9.80 0.00 01-JAN-00:10 9110.11 21-JUL-18:10
Values shown are for all completed run periods - including any simulations run during sizing periods

Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
None          
Values shown are for all completed run periods - including any simulations run during sizing periods

Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [kg/s] Timestamp of Maximum {TIMESTAMP}
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10
Values shown are for all completed run periods - including any simulations run during sizing periods

Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
None          
Values shown are for all completed run periods - including any simulations run during sizing periods

Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum {TIMESTAMP} Maximum Value [L] Timestamp of Maximum {TIMESTAMP}
None          
Values shown are for all completed run periods - including any simulations run during sizing periods

Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
EnergyTransfer:Facility 151.64 0.00 06-MAR-16:10 22048.54 30-JAN-04:00
EnergyTransfer:Building 151.64 0.00 06-MAR-16:10 22048.54 30-JAN-04:00
EnergyTransfer:Zone:TZ_0-A1.B 12.97 0.00 06-MAR-16:10 1782.02 30-JAN-04:00
Heating:EnergyTransfer 144.38 0.00 06-MAR-16:10 22048.54 30-JAN-04:00
Heating:EnergyTransfer:Zone:TZ_0-A1.B 12.92 0.00 06-MAR-16:10 1782.02 30-JAN-04:00
General:Heating:EnergyTransfer 144.38 0.00 06-MAR-16:10 22048.54 30-JAN-04:00
General:Heating:EnergyTransfer:Zone:TZ_0-A1.B 12.92 0.00 06-MAR-16:10 1782.02 30-JAN-04:00
Cooling:EnergyTransfer 7.26 0.00 01-JAN-00:10 6557.56 24-JUL-18:10
Cooling:EnergyTransfer:Zone:TZ_0-A1.B 0.05 0.00 01-JAN-00:10 314.82 21-JUL-19:00
General:Cooling:EnergyTransfer 7.26 0.00 01-JAN-00:10 6557.56 24-JUL-18:10
General:Cooling:EnergyTransfer:Zone:TZ_0-A1.B 0.05 0.00 01-JAN-00:10 314.82 21-JUL-19:00
EnergyTransfer:Zone:TZ_0-A1.LK 12.95 0.00 06-MAR-15:10 2020.78 30-JAN-04:00
Heating:EnergyTransfer:Zone:TZ_0-A1.LK 12.89 0.00 06-MAR-15:10 2020.78 30-JAN-04:00
General:Heating:EnergyTransfer:Zone:TZ_0-A1.LK 12.89 0.00 06-MAR-15:10 2020.78 30-JAN-04:00
Cooling:EnergyTransfer:Zone:TZ_0-A1.LK 0.05 0.00 01-JAN-00:10 380.54 24-JUL-18:10
General:Cooling:EnergyTransfer:Zone:TZ_0-A1.LK 0.05 0.00 01-JAN-00:10 380.54 24-JUL-18:10
EnergyTransfer:Zone:TZ_0-A1.W 4.77 0.00 06-MAR-14:50 713.45 30-JAN-04:00
Heating:EnergyTransfer:Zone:TZ_0-A1.W 4.75 0.00 06-MAR-14:50 713.45 30-JAN-04:00
General:Heating:EnergyTransfer:Zone:TZ_0-A1.W 4.75 0.00 06-MAR-14:50 713.45 30-JAN-04:00
Cooling:EnergyTransfer:Zone:TZ_0-A1.W 0.02 0.00 01-JAN-00:10 116.24 21-JUL-19:00
General:Cooling:EnergyTransfer:Zone:TZ_0-A1.W 0.02 0.00 01-JAN-00:10 116.24 21-JUL-19:00
EnergyTransfer:Zone:TZ_0-A2.B 12.00 0.00 17-FEB-13:20 1711.55 30-JAN-04:00
Heating:EnergyTransfer:Zone:TZ_0-A2.B 11.86 0.00 17-FEB-13:20 1711.55 30-JAN-04:00
General:Heating:EnergyTransfer:Zone:TZ_0-A2.B 11.86 0.00 17-FEB-13:20 1711.55 30-JAN-04:00
Cooling:EnergyTransfer:Zone:TZ_0-A2.B 0.14 0.00 01-JAN-00:10 337.07 21-JUL-19:00
General:Cooling:EnergyTransfer:Zone:TZ_0-A2.B 0.14 0.00 01-JAN-00:10 337.07 21-JUL-19:00
EnergyTransfer:Zone:TZ_0-A2.LK 22.39 0.00 17-FEB-14:30 3362.02 30-JAN-04:00
Heating:EnergyTransfer:Zone:TZ_0-A2.LK 22.11 0.00 17-FEB-14:30 3362.02 30-JAN-04:00
General:Heating:EnergyTransfer:Zone:TZ_0-A2.LK 22.11 0.00 17-FEB-14:30 3362.02 30-JAN-04:00
Cooling:EnergyTransfer:Zone:TZ_0-A2.LK 0.27 0.00 01-JAN-00:10 812.50 24-JUL-18:10
General:Cooling:EnergyTransfer:Zone:TZ_0-A2.LK 0.27 0.00 01-JAN-00:10 812.50 24-JUL-18:10
EnergyTransfer:Zone:TZ_0-A2.W 4.68 0.00 17-FEB-16:10 710.71 30-JAN-04:00
Heating:EnergyTransfer:Zone:TZ_0-A2.W 4.66 0.00 17-FEB-16:10 710.71 30-JAN-04:00
General:Heating:EnergyTransfer:Zone:TZ_0-A2.W 4.66 0.00 17-FEB-16:10 710.71 30-JAN-04:00
Cooling:EnergyTransfer:Zone:TZ_0-A2.W 0.02 0.00 01-JAN-00:10 123.99 21-JUL-19:00
General:Cooling:EnergyTransfer:Zone:TZ_0-A2.W 0.02 0.00 01-JAN-00:10 123.99 21-JUL-19:00
EnergyTransfer:Zone:TZ_0-H 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Heating:EnergyTransfer:Zone:TZ_0-H 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:TZ_0-H 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:TZ_0-H 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cooling:EnergyTransfer:Zone:TZ_0-H 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
EnergyTransfer:Zone:TZ_1-A3.B1 14.40 0.00 01-MAR-14:20 1970.97 30-JAN-04:00
Heating:EnergyTransfer:Zone:TZ_1-A3.B1 13.65 0.00 01-MAR-14:20 1970.97 30-JAN-04:00
General:Heating:EnergyTransfer:Zone:TZ_1-A3.B1 13.65 0.00 01-MAR-14:20 1970.97 30-JAN-04:00
Cooling:EnergyTransfer:Zone:TZ_1-A3.B1 0.75 0.00 01-JAN-00:10 627.54 25-JUL-13:00
General:Cooling:EnergyTransfer:Zone:TZ_1-A3.B1 0.75 0.00 01-JAN-00:10 627.54 25-JUL-13:00
EnergyTransfer:Zone:TZ_1-A3.B2 13.82 0.00 09-FEB-12:40 1903.58 30-JAN-04:00
Heating:EnergyTransfer:Zone:TZ_1-A3.B2 12.67 0.00 09-FEB-12:40 1903.58 30-JAN-04:00
General:Heating:EnergyTransfer:Zone:TZ_1-A3.B2 12.67 0.00 09-FEB-12:40 1903.58 30-JAN-04:00
Cooling:EnergyTransfer:Zone:TZ_1-A3.B2 1.14 0.00 01-JAN-00:10 852.18 23-JUL-13:40
General:Cooling:EnergyTransfer:Zone:TZ_1-A3.B2 1.14 0.00 01-JAN-00:10 852.18 23-JUL-13:40
EnergyTransfer:Zone:TZ_1-A3.LK 42.39 0.00 17-FEB-13:20 6239.18 30-JAN-04:00
Heating:EnergyTransfer:Zone:TZ_1-A3.LK 38.60 0.00 17-FEB-13:20 6239.18 30-JAN-04:00
General:Heating:EnergyTransfer:Zone:TZ_1-A3.LK 38.60 0.00 17-FEB-13:20 6239.18 30-JAN-04:00
Cooling:EnergyTransfer:Zone:TZ_1-A3.LK 3.79 0.00 01-JAN-00:10 2751.98 23-JUL-16:10
General:Cooling:EnergyTransfer:Zone:TZ_1-A3.LK 3.79 0.00 01-JAN-00:10 2751.98 23-JUL-16:10
EnergyTransfer:Zone:TZ_1-A3.W1 5.65 0.00 17-FEB-14:50 817.89 30-JAN-04:00
Heating:EnergyTransfer:Zone:TZ_1-A3.W1 5.17 0.00 17-FEB-14:50 817.89 30-JAN-04:00
General:Heating:EnergyTransfer:Zone:TZ_1-A3.W1 5.17 0.00 17-FEB-14:50 817.89 30-JAN-04:00
Cooling:EnergyTransfer:Zone:TZ_1-A3.W1 0.48 0.00 01-JAN-00:10 343.51 25-JUL-11:40
General:Cooling:EnergyTransfer:Zone:TZ_1-A3.W1 0.48 0.00 01-JAN-00:10 343.51 25-JUL-11:40
EnergyTransfer:Zone:TZ_1-A3.W2 5.63 0.00 17-FEB-13:00 816.40 30-JAN-04:00
Heating:EnergyTransfer:Zone:TZ_1-A3.W2 5.10 0.00 17-FEB-13:00 816.40 30-JAN-04:00
General:Heating:EnergyTransfer:Zone:TZ_1-A3.W2 5.10 0.00 17-FEB-13:00 816.40 30-JAN-04:00
Cooling:EnergyTransfer:Zone:TZ_1-A3.W2 0.53 0.00 01-JAN-00:10 359.87 25-JUL-13:00
General:Cooling:EnergyTransfer:Zone:TZ_1-A3.W2 0.53 0.00 01-JAN-00:10 359.87 25-JUL-13:00
EnergyTransfer:Zone:TZ_1-H 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Heating:EnergyTransfer:Zone:TZ_1-H 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:TZ_1-H 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:TZ_1-H 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cooling:EnergyTransfer:Zone:TZ_1-H 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
DistrictHeatingWater:Facility 144.38 0.00 06-MAR-16:10 22048.54 30-JAN-04:00
DistrictHeatingWater:HVAC 144.38 0.00 06-MAR-16:10 22048.54 30-JAN-04:00
Heating:DistrictHeatingWater 144.38 0.00 06-MAR-16:10 22048.54 30-JAN-04:00
General:Heating:DistrictHeatingWater 144.38 0.00 06-MAR-16:10 22048.54 30-JAN-04:00
Values shown are for all completed run periods - including any simulations run during sizing periods


Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Annual Building Sensible Heat Gain Components

HVAC Zone Eq & Other Sensible Air Heating [GJ] HVAC Zone Eq & Other Sensible Air Cooling [GJ] HVAC Terminal Unit Sensible Air Heating [GJ] HVAC Terminal Unit Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
TZ_0-A1.B 12.918 -0.054 0.000 0.000 0.000 0.000 0.977 0.771 2.146 0.674 0.000 0.183 0.000 0.000 -1.443 0.000 -12.004 -4.169
TZ_0-A1.LK 12.893 -0.054 0.000 0.000 0.000 0.000 1.882 1.496 4.164 1.024 0.000 0.171 0.000 0.000 -2.168 0.000 -11.510 -7.899
TZ_0-A1.W 4.751 -0.016 0.000 0.000 0.000 0.000 0.547 0.434 1.207 0.753 0.000 0.064 0.000 0.000 -0.709 0.000 -4.587 -2.444
TZ_0-A2.B 11.861 -0.137 0.000 0.000 0.000 0.000 0.926 0.735 2.044 2.146 0.000 0.121 0.000 0.000 -1.398 0.000 -11.776 -4.523
TZ_0-A2.LK 22.113 -0.273 0.000 0.000 0.000 0.000 2.466 1.962 5.460 4.756 0.000 0.240 0.000 0.000 -3.468 0.000 -21.458 -11.798
TZ_0-A2.W 4.662 -0.022 0.000 0.000 0.000 0.000 0.546 0.434 1.207 0.748 0.000 0.058 0.000 0.000 -0.712 0.000 -4.602 -2.319
TZ_1-A3.B1 13.650 -0.752 0.000 0.000 0.000 0.000 0.961 0.771 2.146 0.570 0.000 0.100 0.000 0.000 -1.464 0.000 -12.426 -3.555
TZ_1-A3.B2 12.673 -1.145 0.000 0.000 0.000 0.000 0.911 0.735 2.044 2.032 0.000 0.097 0.000 0.000 -1.413 0.000 -12.211 -3.723
TZ_1-A3.LK 38.596 -3.795 0.000 0.000 0.000 0.000 4.269 3.458 9.624 5.232 0.000 0.248 0.000 0.000 -5.584 0.000 -34.197 -17.852
TZ_1-A3.W1 5.167 -0.484 0.000 0.000 0.000 0.000 0.535 0.434 1.207 0.701 0.000 0.035 0.000 0.000 -0.725 0.000 -4.778 -2.092
TZ_1-A3.W2 5.098 -0.532 0.000 0.000 0.000 0.000 0.534 0.434 1.207 0.697 0.000 0.035 0.000 0.000 -0.728 0.000 -4.795 -1.951
TZ_0-H 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.389 0.000 2.632 0.000 0.037 2.007 0.000 -3.180 0.000 -8.884 0.000
TZ_1-H 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.389 0.000 1.439 0.000 0.000 1.550 0.000 -1.080 0.000 -9.298 0.000
Total Facility 144.381 -7.263 0.000 0.000 0.000 0.000 14.554 26.441 32.459 23.402 0.000 1.389 3.557 0.000 -24.071 0.000 -152.526 -62.323


Peak Cooling Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
TZ_0-A1.B 21-JUL-18:00 0.00 -314.86 0.00 0.00 0.00 0.00 28.26 61.73 103.43 59.30 0.00 245.10 0.00 0.00 -0.00 0.00 0.00 -182.97
TZ_0-A1.LK 24-JUL-18:10 0.00 -380.51 0.00 0.00 0.00 0.00 54.84 119.79 200.69 141.43 0.00 210.00 0.00 0.00 -0.00 0.00 0.00 -346.24
TZ_0-A1.W 21-JUL-18:00 0.00 -116.25 0.00 0.00 0.00 0.00 15.90 34.73 58.19 25.61 0.00 93.99 0.00 0.00 -0.00 0.00 0.00 -112.17
TZ_0-A2.B 21-JUL-18:00 0.00 -337.11 0.00 0.00 0.00 0.00 26.92 58.81 98.53 50.55 0.00 237.89 0.00 0.00 -0.00 0.00 0.00 -135.59
TZ_0-A2.LK 24-JUL-18:10 0.00 -812.54 0.00 0.00 0.00 0.00 71.91 157.09 263.18 439.57 0.00 384.58 0.00 0.00 -0.00 0.00 0.00 -503.78
TZ_0-A2.W 21-JUL-18:00 0.00 -124.00 0.00 0.00 0.00 0.00 15.90 34.73 58.19 25.41 0.00 93.99 0.00 0.00 -0.00 0.00 0.00 -104.23
TZ_1-A3.B1 25-JUL-12:00 0.00 -627.39 0.00 0.00 0.00 0.00 8.12 8.86 71.37 129.26 0.00 140.31 269.47 0.00 -0.00 0.00 0.00 0.00
TZ_1-A3.B2 23-JUL-13:39 0.00 -852.16 0.00 0.00 0.00 0.00 7.74 8.44 65.03 386.91 0.00 170.46 213.58 0.00 -0.00 0.00 0.00 0.00
TZ_1-A3.LK 23-JUL-16:10 0.00 -2752.00 0.00 0.00 0.00 0.00 43.71 146.62 371.10 962.00 0.00 477.61 750.96 0.00 -0.00 0.00 0.00 0.00
TZ_1-A3.W1 25-JUL-11:39 0.00 -343.48 0.00 0.00 0.00 0.00 4.57 4.99 40.73 105.47 0.00 36.95 150.77 0.00 -0.00 0.00 0.00 0.00
TZ_1-A3.W2 25-JUL-12:00 0.00 -359.85 0.00 0.00 0.00 0.00 4.57 4.99 40.15 65.03 0.00 48.66 196.46 0.00 -0.00 0.00 0.00 0.00
TZ_0-H - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TZ_1-H - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 24-JUL-18:10 0.00 -6557.96 0.00 0.00 0.00 0.00 427.49 1402.38 1564.43 2401.75 0.00 2368.37 0.00 0.00 0.00 0.00 -131.08 -1475.36


Peak Heating Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
TZ_0-A1.B 30-JAN-03:00 1781.99 0.00 0.00 0.00 0.00 0.00 47.11 4.99 39.30 0.00 0.00 0.00 0.00 0.00 -169.58 0.00 -1441.12 -262.70
TZ_0-A1.LK 30-JAN-03:00 2020.74 0.00 0.00 0.00 0.00 0.00 91.42 9.68 76.26 0.00 0.00 0.00 0.00 0.00 -253.11 0.00 -1452.71 -492.29
TZ_0-A1.W 30-JAN-03:00 713.44 0.00 0.00 0.00 0.00 0.00 26.51 2.81 22.11 0.00 0.00 0.00 0.00 0.00 -85.97 0.00 -561.49 -117.40
TZ_0-A2.B 30-JAN-03:00 1711.52 0.00 0.00 0.00 0.00 0.00 44.88 4.75 37.44 0.00 0.00 0.00 0.00 0.00 -169.98 0.00 -1397.83 -230.80
TZ_0-A2.LK 30-JAN-03:00 3361.97 0.00 0.00 0.00 0.00 0.00 119.89 12.70 100.01 0.00 0.00 0.00 0.00 0.00 -420.83 0.00 -2610.41 -563.31
TZ_0-A2.W 30-JAN-03:00 710.69 0.00 0.00 0.00 0.00 0.00 26.51 2.81 22.11 0.00 0.00 0.00 0.00 0.00 -86.01 0.00 -561.49 -114.62
TZ_1-A3.B1 30-JAN-03:00 1970.93 0.00 0.00 0.00 0.00 0.00 47.11 4.99 39.30 0.00 0.00 0.00 0.00 0.00 -166.49 0.00 -1442.03 -453.82
TZ_1-A3.B2 30-JAN-03:00 1903.55 0.00 0.00 0.00 0.00 0.00 44.88 4.75 37.44 0.00 0.00 0.00 0.00 0.00 -166.72 0.00 -1398.71 -425.19
TZ_1-A3.LK 30-JAN-03:00 6239.07 0.00 0.00 0.00 0.00 0.00 211.31 22.38 176.27 0.00 0.00 0.00 0.00 0.00 -653.82 0.00 -4065.70 -1929.51
TZ_1-A3.W1 30-JAN-03:00 817.87 0.00 0.00 0.00 0.00 0.00 26.51 2.81 22.11 0.00 0.00 0.00 0.00 0.00 -84.67 0.00 -561.85 -222.78
TZ_1-A3.W2 30-JAN-03:00 816.39 0.00 0.00 0.00 0.00 0.00 26.51 2.81 22.11 0.00 0.00 0.00 0.00 0.00 -84.70 0.00 -561.85 -221.27
TZ_0-H - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TZ_1-H - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 30-JAN-03:00 22048.15 0.00 0.00 0.00 0.00 0.00 712.65 544.07 594.48 0.00 0.00 0.00 0.00 0.00 -2773.14 0.00 -17651.29 -3474.92



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Sec1.1A-General Information

Data
Weather File RUN PERIOD 1 ** MILAN - ITA IWEC Data WMO#=160660
Total gross floor area [m2] 338.00
Principal Heating Source District Heating Water


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
TZ_0-A1.B 19.22 19.22 0.00 168.00
TZ_0-A1.LK 37.29 37.29 0.00 168.00
TZ_0-A1.W 10.81 10.81 0.00 168.00
TZ_0-A2.B 18.31 18.31 0.00 168.00
TZ_0-A2.LK 48.90 48.90 0.00 168.00
TZ_0-A2.W 10.81 10.81 0.00 168.00
TZ_1-A3.B1 19.22 19.22 0.00 168.00
TZ_1-A3.B2 18.31 18.31 0.00 168.00
TZ_1-A3.LK 86.19 86.19 0.00 168.00
TZ_1-A3.W1 10.81 10.81 0.00 168.00
TZ_1-A3.W2 10.81 10.81 0.00 168.00
TZ_0-H 23.66 0.00 23.66 0.00
TZ_1-H 23.66 0.00 23.66 0.00
Totals 338.00 290.68 47.32  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 0.00
Number of hours cooling loads not met 0.00
Number of hours not met 0.00


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electricity Energy Use [GJ] Electricity Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Gasoline Use [GJ] Gasoline Demand [W] Diesel Use [GJ] Diesel Demand [W] Coal Use [GJ] Coal Demand [W] Fuel Oil No 1 Use [GJ] Fuel Oil No 1 Demand [W] Fuel Oil No 2 Use [GJ] Fuel Oil No 2 Demand [W] Propane Use [GJ] Propane Demand [W] Other Fuel 1 Use [GJ] Other Fuel 1 Demand [W] Other Fuel 2 Use [GJ] Other Fuel 2 Demand [W] District Cooling Use [GJ] District Cooling Demand [W] District Heating Water Use [GJ] District Heating Water Demand [W] District Heating Steam Use [GJ] District Heating Steam Demand [W]
Heating -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 144.38 22048.54 0.00 0.00
Cooling -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9.80 9110.11 0.00 0.00 0.00 0.00
Interior Lighting -- General 26.44 1594.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- General 32.46 1564.43 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans -- Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 32.46 58.90
Natural Gas 0.00 0.00
Additional 0.00 154.18
Total 32.46 213.08


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting (All) 78.23
Space Heating 0.00
Space Cooling 0.00
Fans (All) 0.00
Service Water Heating 0.00
Receptacle Equipment 96.03
Miscellaneous (All) 174.26
Subtotal 174.26


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 0.00
Service Water Heating 0.00
Miscellaneous (All) 0.00
Subtotal 0.00


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Subtotal 0.00
Miscellaneous 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting (All) 12.41
Space Heating 67.76
Space Cooling 4.60
Fans (All) 0.00
Service Water Heating 0.00
Receptacle Equipment 15.23
Miscellaneous -0.00


Schedules-Equivalent Full Load Hours (Schedule Type=Fraction)

Equivalent Full Load Hours of Operation Per Year [hr] Hours > 1% [hr]
None    


Schedules-SetPoints (Schedule Type=Temperature)

First Object Used Month Assumed 11am First Wednesday [C] Days with Same 11am Value 11pm First Wednesday [C] Days with Same 11pm Value
HEATING SETPOINT THERMOSTAT SETPOINT DUAL SETPOINT 1 January 20.00 365 20.00 365
COOLING SETPOINT THERMOSTAT SETPOINT DUAL SETPOINT 1 July 26.00 365 26.00 365



Table of Contents

Report: Annual CO2 Resilience Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

CO2 Level Hours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      


CO2 Level OccupantHours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      


CO2 Level OccupiedHours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      



Table of Contents

Report: Annual Visual Resilience Summary

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Illuminance Level Hours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
None        


Illuminance Level OccupantHours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
None        


Illuminance Level OccupiedHours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
None        



Table of Contents

Report: BUILDING ENERGY PERFORMANCE - ELECTRICITY

For: Meter

Timestamp: 2024-09-12 18:15:00

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY [J] EXTERIORLIGHTS:ELECTRICITY [] INTERIOREQUIPMENT:ELECTRICITY [J] EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY [J] PUMPS:ELECTRICITY [] HEATING:ELECTRICITY [] COOLING:ELECTRICITY [] HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY [] WATERSYSTEMS:ELECTRICITY [] COGENERATION:ELECTRICITY [] REFRIGERATION:ELECTRICITY []
January 0.224565E+10 0.00 0.275678E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.202833E+10 0.00 0.248999E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.224565E+10 0.00 0.275678E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.217321E+10 0.00 0.266785E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.224565E+10 0.00 0.275678E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.217321E+10 0.00 0.266785E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.224565E+10 0.00 0.275678E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.224565E+10 0.00 0.275678E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.217321E+10 0.00 0.266785E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.224565E+10 0.00 0.275678E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.217321E+10 0.00 0.266785E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.224565E+10 0.00 0.275678E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                             
Annual Sum or Average 0.264408E+11 0.00 0.324588E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.202833E+10 0.00 0.248999E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.224565E+10 0.00 0.275678E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: BUILDING ENERGY PERFORMANCE - DISTRICT HEATING WATER

For: Meter

Timestamp: 2024-09-12 18:15:00

Custom Monthly Report

INTERIORLIGHTS:DISTRICTHEATINGWATER [] EXTERIORLIGHTS:DISTRICTHEATINGWATER [] INTERIOREQUIPMENT:DISTRICTHEATINGWATER [] EXTERIOREQUIPMENT:DISTRICTHEATINGWATER [] FANS:DISTRICTHEATINGWATER [] PUMPS:DISTRICTHEATINGWATER [] HEATING:DISTRICTHEATINGWATER [J] COOLING:DISTRICTHEATINGWATER [] HEATREJECTION:DISTRICTHEATINGWATER [] HUMIDIFIER:DISTRICTHEATINGWATER [] HEATRECOVERY:DISTRICTHEATINGWATER [] WATERSYSTEMS:DISTRICTHEATINGWATER [] COGENERATION:DISTRICTHEATINGWATER []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.312373E+11 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.241887E+11 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.163467E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.103462E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.338604E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.967773E+09 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 26575377.95 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 99210210.56 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.228458E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.859973E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.189450E+11 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.279540E+11 0.00 0.00 0.00 0.00 0.00 0.00
                           
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.144382E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 26575377.95 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.312373E+11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: BUILDING ENERGY PERFORMANCE - DISTRICT COOLING

For: Meter

Timestamp: 2024-09-12 18:15:00

Custom Monthly Report

INTERIORLIGHTS:DISTRICTCOOLING [] EXTERIORLIGHTS:DISTRICTCOOLING [] INTERIOREQUIPMENT:DISTRICTCOOLING [] EXTERIOREQUIPMENT:DISTRICTCOOLING [] FANS:DISTRICTCOOLING [] PUMPS:DISTRICTCOOLING [] HEATING:DISTRICTCOOLING [] COOLING:DISTRICTCOOLING [J] HEATREJECTION:DISTRICTCOOLING [] HUMIDIFIER:DISTRICTCOOLING [] HEATRECOVERY:DISTRICTCOOLING [] WATERSYSTEMS:DISTRICTCOOLING [] COGENERATION:DISTRICTCOOLING []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 205507.98 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3355020.40 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.422799E+09 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.197960E+10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.417260E+10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.262467E+10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.591483E+09 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3596182.28 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.979831E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.417260E+10 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: BUILDING ENERGY PERFORMANCE - ELECTRICITY PEAK DEMAND

For: Meter

Timestamp: 2024-09-12 18:15:00

Custom Monthly Report

ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY [] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY [] HEATING:ELECTRICITY [] COOLING:ELECTRICITY [] HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY [] WATERSYSTEMS:ELECTRICITY [] COGENERATION:ELECTRICITY [] REFRIGERATION:ELECTRICITY []
January 3034.14 01-JAN-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 3034.14 01-FEB-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 3034.14 01-MAR-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 3034.14 01-APR-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 3034.14 01-MAY-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 3034.14 01-JUN-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 3034.14 01-JUL-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 3034.14 01-AUG-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 3034.14 01-SEP-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 3034.14 01-OCT-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 3034.14 01-NOV-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 3034.14 01-DEC-19:20 1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                                 
Annual Sum or Average       0.00   0.00   0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 3034.14   1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3034.14   1579.22 0.00 1454.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: BUILDING ENERGY PERFORMANCE - DISTRICT HEATING WATER PEAK DEMAND

For: Meter

Timestamp: 2024-09-12 18:15:00

Custom Monthly Report

DISTRICTHEATINGWATER:FACILITY {Maximum} [W] DISTRICTHEATINGWATER:FACILITY {TIMESTAMP} INTERIORLIGHTS:DISTRICTHEATINGWATER [] EXTERIORLIGHTS:DISTRICTHEATINGWATER [] INTERIOREQUIPMENT:DISTRICTHEATINGWATER [] EXTERIOREQUIPMENT:DISTRICTHEATINGWATER [] FANS:DISTRICTHEATINGWATER [] PUMPS:DISTRICTHEATINGWATER [] HEATING:DISTRICTHEATINGWATER {AT MAX/MIN} [W] COOLING:DISTRICTHEATINGWATER [] HEATREJECTION:DISTRICTHEATINGWATER [] HUMIDIFIER:DISTRICTHEATINGWATER [] HEATRECOVERY:DISTRICTHEATINGWATER [] WATERSYSTEMS:DISTRICTHEATINGWATER [] COGENERATION:DISTRICTHEATINGWATER []
January 22048.54 30-JAN-03:10 0.00 0.00 0.00 0.00 0.00 0.00 22048.54 0.00 0.00 0.00 0.00 0.00 0.00
February 18117.73 24-FEB-03:10 0.00 0.00 0.00 0.00 0.00 0.00 18117.73 0.00 0.00 0.00 0.00 0.00 0.00
March 15679.92 01-MAR-05:10 0.00 0.00 0.00 0.00 0.00 0.00 15679.92 0.00 0.00 0.00 0.00 0.00 0.00
April 14052.55 01-APR-05:10 0.00 0.00 0.00 0.00 0.00 0.00 14052.55 0.00 0.00 0.00 0.00 0.00 0.00
May 8054.21 22-MAY-03:10 0.00 0.00 0.00 0.00 0.00 0.00 8054.21 0.00 0.00 0.00 0.00 0.00 0.00
June 7747.35 13-JUN-03:10 0.00 0.00 0.00 0.00 0.00 0.00 7747.35 0.00 0.00 0.00 0.00 0.00 0.00
July 1016.89 15-JUL-03:10 0.00 0.00 0.00 0.00 0.00 0.00 1016.89 0.00 0.00 0.00 0.00 0.00 0.00
August 2386.39 13-AUG-04:10 0.00 0.00 0.00 0.00 0.00 0.00 2386.39 0.00 0.00 0.00 0.00 0.00 0.00
September 7375.96 29-SEP-03:10 0.00 0.00 0.00 0.00 0.00 0.00 7375.96 0.00 0.00 0.00 0.00 0.00 0.00
October 12158.94 31-OCT-06:10 0.00 0.00 0.00 0.00 0.00 0.00 12158.94 0.00 0.00 0.00 0.00 0.00 0.00
November 15499.71 19-NOV-05:10 0.00 0.00 0.00 0.00 0.00 0.00 15499.71 0.00 0.00 0.00 0.00 0.00 0.00
December 19707.85 29-DEC-06:10 0.00 0.00 0.00 0.00 0.00 0.00 19707.85 0.00 0.00 0.00 0.00 0.00 0.00
                               
Annual Sum or Average     0.00 0.00 0.00 0.00 0.00 0.00   0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 1016.89   0.00 0.00 0.00 0.00 0.00 0.00 1016.89 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 22048.54   0.00 0.00 0.00 0.00 0.00 0.00 22048.54 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: BUILDING ENERGY PERFORMANCE - DISTRICT COOLING PEAK DEMAND

For: Meter

Timestamp: 2024-09-12 18:15:00

Custom Monthly Report

DISTRICTCOOLING:FACILITY {Maximum} [W] DISTRICTCOOLING:FACILITY {TIMESTAMP} INTERIORLIGHTS:DISTRICTCOOLING [] EXTERIORLIGHTS:DISTRICTCOOLING [] INTERIOREQUIPMENT:DISTRICTCOOLING [] EXTERIOREQUIPMENT:DISTRICTCOOLING [] FANS:DISTRICTCOOLING [] PUMPS:DISTRICTCOOLING [] HEATING:DISTRICTCOOLING [] COOLING:DISTRICTCOOLING {AT MAX/MIN} [W] HEATREJECTION:DISTRICTCOOLING [] HUMIDIFIER:DISTRICTCOOLING [] HEATRECOVERY:DISTRICTCOOLING [] WATERSYSTEMS:DISTRICTCOOLING [] COGENERATION:DISTRICTCOOLING []
January 0.00 01-JAN-00:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 01-FEB-00:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 36.13 15-MAR-15:30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 36.13 0.00 0.00 0.00 0.00 0.00
April 331.89 23-APR-16:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 331.89 0.00 0.00 0.00 0.00 0.00
May 2891.62 25-MAY-16:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2891.62 0.00 0.00 0.00 0.00 0.00
June 7881.15 26-JUN-17:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 7881.15 0.00 0.00 0.00 0.00 0.00
July 9110.11 21-JUL-18:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9110.11 0.00 0.00 0.00 0.00 0.00
August 6747.23 06-AUG-16:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 6747.23 0.00 0.00 0.00 0.00 0.00
September 4092.94 01-SEP-16:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4092.94 0.00 0.00 0.00 0.00 0.00
October 143.91 12-OCT-14:39 0.00 0.00 0.00 0.00 0.00 0.00 0.00 143.91 0.00 0.00 0.00 0.00 0.00
November 0.00 01-NOV-00:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 01-DEC-00:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                               
Annual Sum or Average     0.00 0.00 0.00 0.00 0.00 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00   0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 9110.11   0.00 0.00 0.00 0.00 0.00 0.00 0.00 9110.11 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Life-Cycle Cost Report

For: Entire Facility

Timestamp: 2024-09-12 18:15:00

Life-Cycle Cost Parameters

Value
Name LIFE CYCLE COST PARAMETERS
Discounting Convention EndOfYear
Inflation Approach ConstantDollar
Real Discount Rate 0.0300
Nominal Discount Rate -- N/A --
Inflation -- N/A --
Base Date January 2011
Service Date January 2011
Length of Study Period in Years 25
Tax rate 0.0000
Depreciation Method None


Use Price Escalation

U.S. AVG COMMERCIAL-ELECTRICITY U.S. AVG COMMERCIAL-DISTILLATE OIL U.S. AVG COMMERCIAL-RESIDUAL OIL U.S. AVG COMMERCIAL-NATURAL GAS U.S. AVG COMMERCIAL-COAL
Resource Electricity FuelOilNo1 FuelOilNo2 NaturalGas Coal
Start Date January 2011 January 2011 January 2011 January 2011 January 2011
1 0.983800 0.971400 0.846900 0.982300 0.997000
2 0.973000 0.973000 0.825700 0.955700 1.008900
3 0.963200 0.994200 0.868100 0.927900 1.008900
4 0.961100 1.016400 0.898800 0.925700 0.994100
5 0.957100 1.054100 0.928900 0.934600 0.994100
6 0.955300 1.092800 0.960400 0.941200 1.000000
7 0.953900 1.126700 0.989700 0.951200 1.003000
8 0.952100 1.158000 1.007500 0.964500 1.005900
9 0.954600 1.179200 1.031400 0.985600 1.008900
10 0.955000 1.196700 1.055400 1.006700 1.011900
11 0.955300 1.220000 1.086100 1.022200 1.014800
12 0.956400 1.233300 1.127800 1.041000 1.017800
13 0.957500 1.256600 1.149700 1.061000 1.020800
14 0.959600 1.270900 1.162000 1.078700 1.026700
15 0.961800 1.282600 1.174300 1.094200 1.029700
16 0.961400 1.298500 1.185200 1.109800 1.035600
17 0.961800 1.310200 1.194800 1.122000 1.041500
18 0.961800 1.325000 1.203700 1.130800 1.053400
19 0.959300 1.326100 1.207100 1.138600 1.056400
20 0.958900 1.328200 1.211900 1.148600 1.059300
21 0.960700 1.332400 1.213900 1.161900 1.065300
22 0.962500 1.335600 1.219400 1.176300 1.071200
23 0.965000 1.343100 1.227600 1.191800 1.074200
24 0.970800 1.351000 1.236500 1.211800 1.080100
25 0.975100 1.356800 1.242000 1.228400 1.083100


Cash Flow for Recurring and Nonrecurring Costs (Without Escalation)

DEFAULT COST
  Nonrecurring
January 2011 0.00
January 2012 0.00
January 2013 0.00
January 2014 0.00
January 2015 0.00
January 2016 0.00
January 2017 0.00
January 2018 0.00
January 2019 0.00
January 2020 0.00
January 2021 0.00
January 2022 0.00
January 2023 0.00
January 2024 0.00
January 2025 0.00
January 2026 0.00
January 2027 0.00
January 2028 0.00
January 2029 0.00
January 2030 0.00
January 2031 0.00
January 2032 0.00
January 2033 0.00
January 2034 0.00
January 2035 0.00


Energy and Water Cost Cash Flows (Without Escalation)

Total
January 2011 0.00
January 2012 0.00
January 2013 0.00
January 2014 0.00
January 2015 0.00
January 2016 0.00
January 2017 0.00
January 2018 0.00
January 2019 0.00
January 2020 0.00
January 2021 0.00
January 2022 0.00
January 2023 0.00
January 2024 0.00
January 2025 0.00
January 2026 0.00
January 2027 0.00
January 2028 0.00
January 2029 0.00
January 2030 0.00
January 2031 0.00
January 2032 0.00
January 2033 0.00
January 2034 0.00
January 2035 0.00


Energy and Water Cost Cash Flows (With Escalation)

Total
January 2011 0.00
January 2012 0.00
January 2013 0.00
January 2014 0.00
January 2015 0.00
January 2016 0.00
January 2017 0.00
January 2018 0.00
January 2019 0.00
January 2020 0.00
January 2021 0.00
January 2022 0.00
January 2023 0.00
January 2024 0.00
January 2025 0.00
January 2026 0.00
January 2027 0.00
January 2028 0.00
January 2029 0.00
January 2030 0.00
January 2031 0.00
January 2032 0.00
January 2033 0.00
January 2034 0.00
January 2035 0.00


Capital Cash Flow by Category (Without Escalation)

Construction Salvage OtherCapital Total
January 2011 0.00 0.00 0.00 0.00
January 2012 0.00 0.00 0.00 0.00
January 2013 0.00 0.00 0.00 0.00
January 2014 0.00 0.00 0.00 0.00
January 2015 0.00 0.00 0.00 0.00
January 2016 0.00 0.00 0.00 0.00
January 2017 0.00 0.00 0.00 0.00
January 2018 0.00 0.00 0.00 0.00
January 2019 0.00 0.00 0.00 0.00
January 2020 0.00 0.00 0.00 0.00
January 2021 0.00 0.00 0.00 0.00
January 2022 0.00 0.00 0.00 0.00
January 2023 0.00 0.00 0.00 0.00
January 2024 0.00 0.00 0.00 0.00
January 2025 0.00 0.00 0.00 0.00
January 2026 0.00 0.00 0.00 0.00
January 2027 0.00 0.00 0.00 0.00
January 2028 0.00 0.00 0.00 0.00
January 2029 0.00 0.00 0.00 0.00
January 2030 0.00 0.00 0.00 0.00
January 2031 0.00 0.00 0.00 0.00
January 2032 0.00 0.00 0.00 0.00
January 2033 0.00 0.00 0.00 0.00
January 2034 0.00 0.00 0.00 0.00
January 2035 0.00 0.00 0.00 0.00


Operating Cash Flow by Category (Without Escalation)

Maintenance Repair Operation Replacement MinorOverhaul MajorOverhaul OtherOperational Water Energy Total
January 2011 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2012 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2013 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2014 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2015 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2016 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2017 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2018 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2019 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2020 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2021 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2022 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2023 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2024 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2025 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2026 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2027 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2028 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2029 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2030 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2031 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2032 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2033 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2034 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2035 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Operating Cash Flow by Category (With Escalation)

Maintenance Repair Operation Replacement MinorOverhaul MajorOverhaul OtherOperational Water Energy Total
January 2011 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2012 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2013 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2014 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2015 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2016 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2017 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2018 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2019 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2020 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2021 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2022 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2023 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2024 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2025 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2026 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2027 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2028 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2029 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2030 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2031 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2032 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2033 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2034 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
January 2035 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Monthly Total Cash Flow (Without Escalation)

January February March April May June July August September October November December
2011 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2012 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2013 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2014 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2015 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2016 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2017 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2018 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2019 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2020 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2021 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2022 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2023 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2024 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2025 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2026 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2027 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2028 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2029 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2030 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2031 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2032 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2033 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2034 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2035 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Present Value for Recurring, Nonrecurring and Energy Costs (Before Tax)

Category Kind Cost Present Value Present Value Factor
DEFAULT COST Construction Nonrecurring 0.00 0.00 -
TOTAL       0.00  


Present Value by Category

Present Value
Maintenance 0.00
Repair 0.00
Operation 0.00
Replacement 0.00
Minor Overhaul 0.00
Major Overhaul 0.00
Other Operational 0.00
Water 0.00
Energy 0.00
Total Operation 0.00
Construction 0.00
Salvage 0.00
Other Capital 0.00
Total Capital 0.00
Total Energy 0.00
Grand Total 0.00


Present Value by Year

Total Cost (Without Escalation) Total Cost (With Escalation) Present Value of Costs
January 2011 0.00 0.00 0.00
January 2012 0.00 0.00 0.00
January 2013 0.00 0.00 0.00
January 2014 0.00 0.00 0.00
January 2015 0.00 0.00 0.00
January 2016 0.00 0.00 0.00
January 2017 0.00 0.00 0.00
January 2018 0.00 0.00 0.00
January 2019 0.00 0.00 0.00
January 2020 0.00 0.00 0.00
January 2021 0.00 0.00 0.00
January 2022 0.00 0.00 0.00
January 2023 0.00 0.00 0.00
January 2024 0.00 0.00 0.00
January 2025 0.00 0.00 0.00
January 2026 0.00 0.00 0.00
January 2027 0.00 0.00 0.00
January 2028 0.00 0.00 0.00
January 2029 0.00 0.00 0.00
January 2030 0.00 0.00 0.00
January 2031 0.00 0.00 0.00
January 2032 0.00 0.00 0.00
January 2033 0.00 0.00 0.00
January 2034 0.00 0.00 0.00
January 2035 0.00 0.00 0.00
TOTAL     0.00